Digital Thermometers

Digital Thermometers measure temperature using a probe, and give a digital reading via a screen. They are easy to use with a simple display interface. The type of sensor determines how the thermometer works, for example resistance temperature detector (RTD), thermocouples and thermistors.
Probe thermometers are a popular type of thermometer as they provide instant temperature readings. By placing the pointed probe into the sample you are testing, you can ensure it is the right temperature to meet any necessary standards.

There are a range of different probes which will vary in shape, size and material.
Digital thermometers are becoming increasingly popular in comparison to a liquid thermometer and they provide better accuracy and ease of use. Calibration is highly recommended for professional applications which require an accurate reading.
Handheld thermometers are great for portability, whereas panel-mount devices are a more permanent solution.

Uses for Digital Thermometers:
  • Food industry
  • Hygiene testing
  • Industrial maintenance
  • Heating & ventilation
  • Scientific research
  • Medical testing
  • General purpose temperature monitoring

...
Read more Read less

Filters

Viewing 1 - 20 of 231 products
Results per page
Description Price Absolute Maximum Temperature Measurement Calibrated Thermometer Type Probe Type Application Best Accuracy Communication Protocol Number of Temperature Inputs Resolution Data Storage Length Width Height Dimensions
RS Stock No. 123-2250
BrandRS PRO
kr 1 696,50
Each
Units
+1090 (J) °C, +1300 (N) °C, +1370 (K) °C, +1598 (E) °F, +1767 (R) °C, +1767 (S) °C, +1994 (J) °F, +1999.9 (K) °F, +1999.9 (N) °F, +1999.9 (R) °F, +1999.9 (S) °F, +400 (T) °C, +752 (T) °F, +870 (E) °C RSCAL Handheld E, J, K, N, R, S, T - ± 0.05 % + 2 (S) °C, ±0.05 % + 0.5 (E) °C, ±0.05 % + 0.5 (J) °C, ±0.05 % + 0.5 (K) °C, ±0.05 % + 0.5 (N) °C, ±0.05 % + 0.5 (T) °C, ±0.05 % + 0.9 (E) °F, ±0.05 % + 0.9 (J) °F, ±0.05 % + 0.9 (K) °F, ±0.05 % + 0.9 (N) °F, ±0.05 % + 0.9 (T) °F, ±0.05 % + 2 (R) °C, ±0.05 % + 4 (R) °F, ±0.05 % + 4 (S) °F - 2 0.1 (E) °F, 0.1 (E) °C, 0.1 (E) K, 0.1 (J) °C, 0.1 (J) °F, 0.1 (J) K, 0.1 (K) °C, 0.1 (K) °F, 0.1 (K) K, 0.1 (N) °C, 0.1 (N) °F, 0.1 (N) K, 0.1 (T) °C, 0.1 (T) K, 0.1 (T) °F, 1 (R) K, 1 (R) °C, 1 (R) °F, 1 (S) °C, 1 (S) °F, 1 (S) K - 72mm 35mm 150mm 72 x 35 x 150mm
RS Stock No. 123-2212
BrandRS PRO
kr 1 131,50
Each
Units
+1090 (J) °C, +1300 (N) °C, +1370 (K) °C, +1598 (E) °F, +1767 (R) °C, +1767 (S) °C, +1994 (J) °F, +1999.9 (K) °F, +1999.9 (N) °F, +1999.9 (R) °F, +1999.9 (S) °F, +400 (T) °C, +752 (T) °F, +870 (E) °C - Handheld E, J, K, N, R, S, T - ±0.05 % - 2 0.1 K - 72mm 35mm 150mm 72 x 35 x 150mm
RS Stock No. 123-2251
BrandRS PRO
kr 1 906,50
Each
Units
+1090 (J) °C, +1300 (N) °C, +1370 (K) °C, +1598 (E) °F, +1767 (R) °C, +1767 (S) °C, +1994 (J) °F, +1999.9 (K) °F, +1999.9 (N) °F, +1999.9 (R) °F, +1999.9 (S) °F, +400 (T) °C, +752 (T) °F, +870 (E) °C UKAS Handheld E, J, K, N, R, S, T - ± 0.05 % + 2 (S) °C, ±0.05 % + 0.5 (E) °C, ±0.05 % + 0.5 (J) °C, ±0.05 % + 0.5 (K) °C, ±0.05 % + 0.5 (N) °C, ±0.05 % + 0.5 (T) °C, ±0.05 % + 0.9 (E) °F, ±0.05 % + 0.9 (J) °F, ±0.05 % + 0.9 (K) °F, ±0.05 % + 0.9 (N) °F, ±0.05 % + 0.9 (T) °F, ±0.05 % + 2 (R) °C, ±0.05 % + 4 (R) °F, ±0.05 % + 4 (S) °F - 2 0.1 (E) °F, 0.1 (E) °C, 0.1 (E) K, 0.1 (J) °C, 0.1 (J) °F, 0.1 (J) K, 0.1 (K) °C, 0.1 (K) °F, 0.1 (K) K, 0.1 (N) °C, 0.1 (N) °F, 0.1 (N) K, 0.1 (T) °C, 0.1 (T) K, 0.1 (T) °F, 1 (R) K, 1 (R) °C, 1 (R) °F, 1 (S) °C, 1 (S) °F, 1 (S) K - 72mm 35mm 150mm 72 x 35 x 150mm
RS Stock No. 123-2366
BrandRS PRO
kr 1 556,92
Each
Units
+1090 (J) °C, +1300 (N) °C, +1370 (K) °C, +1598 (E) °F, +1767 (R) °C, +1767 (S) °C, +1994 (J) °F, +1999.9 (K) °F, +1999.9 (N) °F, +1999.9 (R) °F, +1999.9 (S) °F, +400 (T) °C, +752 (T) °F, +870 (E) °C RSCAL - E, J, K, N, R, S, T - ± 0.05 % + 2 (S) °C, ±0.05 % + 0.5 (E) °C, ±0.05 % + 0.5 (J) °C, ±0.05 % + 0.5 (K) °C, ±0.05 % + 0.5 (N) °C, ±0.05 % + 0.5 (T) °C, ±0.05 % + 0.9 (E) °F, ±0.05 % + 0.9 (J) °F, ±0.05 % + 0.9 (K) °F, ±0.05 % + 0.9 (N) °F, ±0.05 % + 0.9 (T) °F, ±0.05 % + 2 (R) °C, ±0.05 % + 4 (R) °F, ±0.05 % + 4 (S) °F - 1 0.1 (E) °C, 0.1 (E) °F, 0.1 (E) K, 0.1 (J) K, 0.1 (J) °F, 0.1 (J) °C, 0.1 (K) °C, 0.1 (K) K, 0.1 (K) °F, 0.1 (N) °F, 0.1 (N) K, 0.1 (N) °C, 0.1 (T) °C, 0.1 (T) K, 0.1 (T) °F, 1 (R) K, 1 (R) °C, 1 (R) °F, 1 (S) K, 1 (S) °C, 1 (S) °F - 72mm 35mm 150mm 72 x 35 x 150mm
RS Stock No. 123-2367
BrandRS PRO
kr 1 766,92
Each
Units
+1090 (J) °C, +1300 (N) °C, +1370 (K) °C, +1598 (E) °F, +1767 (R) °C, +1767 (S) °C, +1994 (J) °F, +1999.9 (K) °F, +1999.9 (N) °F, +1999.9 (R) °F, +1999.9 (S) °F, +400 (T) °C, +752 (T) °F, +870 (E) °C UKAS - E, J, K, N, R, S, T - ± 0.05 % + 2 (S) °C, ±0.05 % + 0.5 (E) °C, ±0.05 % + 0.5 (J) °C, ±0.05 % + 0.5 (K) °C, ±0.05 % + 0.5 (N) °C, ±0.05 % + 0.5 (T) °C, ±0.05 % + 0.9 (E) °F, ±0.05 % + 0.9 (J) °F, ±0.05 % + 0.9 (K) °F, ±0.05 % + 0.9 (N) °F, ±0.05 % + 0.9 (T) °F, ±0.05 % + 2 (R) °C, ±0.05 % + 4 (R) °F, ±0.05 % + 4 (S) °F - 1 0.1 (E) °C, 0.1 (E) °F, 0.1 (E) K, 0.1 (J) K, 0.1 (J) °F, 0.1 (J) °C, 0.1 (K) °C, 0.1 (K) K, 0.1 (K) °F, 0.1 (N) °F, 0.1 (N) K, 0.1 (N) °C, 0.1 (T) °C, 0.1 (T) K, 0.1 (T) °F, 1 (R) K, 1 (R) °C, 1 (R) °F, 1 (S) K, 1 (S) °C, 1 (S) °F - 72mm 35mm 150mm 72 x 35 x 150mm
RS Stock No. 123-2211
BrandRS PRO
kr 991,92
Each
Units
+1090 (J) °C, +1300 (N) °C, +1370 (K) °C, +1598 (E) °F, +1767 (R) °C, +1767 (S) °C, +1994 (J) °F, +1999.9 (K) °F, +1999.9 (N) °F, +1999.9 (R) °F, +1999.9 (S) °F, +400 (T) °C, +752 (T) °F, +870 (E) °C - - E, J, K, N, R, S, T - ±0.05 % - 1 0.1 K - 72mm 35mm 150mm 72 x 35 x 150mm
RS Stock No. 123-3215
BrandRS PRO
kr 709,56
Each
Units
+1300 °C, +1999 °F - Handheld K - ±0.1 K - 1 0.1 °C, 0.2 °F No 74mm 39mm 170mm 74 x 39 x 170mm
RS Stock No. 136-8869
BrandRS PRO
kr 1 274,56
Each
Units
+1300 °C, +1999 °F SYSCAL Handheld K - ±0.3 % - 1 0.1 °C, 0.2 °F Yes 74mm 39mm 170mm 74 x 39 x 170mm
RS Stock No. 123-3275
BrandRS PRO
kr 1 274,56
Each
Units
+1300 °C, +1999 °F RSCAL Handheld K - ±0.3 % - 1 0.1 °C, 0.2 °F Yes 74mm 39mm 170mm 74 x 39 x 170mm
RS Stock No. 123-3276
BrandRS PRO
kr 1 484,56
Each
Units
+1300 °C, +1999 °F UKAS Handheld K - ±0.3 % - 1 0.1 °C, 0.2 °F Yes 74mm 39mm 170mm 74 x 39 x 170mm
RS Stock No. 656-5660
BrandRS PRO
kr 94,72
Each
Units
+50°C - LCD - Wall/Desk - - 1 - - 111mm 54.5mm 17mm 111 x 54.5 x 17 + base 28.5mm
RS Stock No. 123-3297
BrandRS PRO
kr 1 429,50
Each
Units
+1300 °C, +1999 °F RSCAL Handheld K - ±0.3 % - 2 0.1 °C, 0.2 °F Yes 74mm 39mm 170mm 74 x 39 x 170mm
RS Stock No. 123-2280
BrandRS PRO
kr 2 785,25
Each
Units
+1090 (J) °C, +1300 (N) °C, +1370 (K) °C, +1598 (E) °F, +1767 (R) °C, +1767 (S) °C, +1994 (J) °F, +1999.9 (K) °F, +1999.9 (N) °F, +1999.9 (R) °F, +1999.9 (S) °F, +400 (T) °C, +752 (T) °F, +870 (E) °C UKAS Handheld E, J, K, N, R, S, T - ± 0.05 % + 2 (S) °C, ±0.05 % + 0.5 (E) °C, ±0.05 % + 0.5 (J) °C, ±0.05 % + 0.5 (K) °C, ±0.05 % + 0.5 (N) °C, ±0.05 % + 0.5 (T) °C, ±0.05 % + 0.9 (E) °F, ±0.05 % + 0.9 (J) °F, ±0.05 % + 0.9 (K) °F, ±0.05 % + 0.9 (N) °F, ±0.05 % + 0.9 (T) °F, ±0.05 % + 2 (R) °C, ±0.05 % + 4 (R) °F, ±0.05 % + 4 (S) °F - 2 0.1 (E) °F, 0.1 (E) °C, 0.1 (E) K, 0.1 (J) °C, 0.1 (J) K, 0.1 (J) °F, 0.1 (K) K, 0.1 (K) °C, 0.1 (K) °F, 0.1 (N) °F, 0.1 (N) K, 0.1 (N) °C, 0.1 (T) °F, 0.1 (T) °C, 0.1 (T) K, 1 (R) °F, 1 (R) °C, 1 (R) K, 1 (S) °F, 1 (S) °C, 1 (S) K Yes 72mm 35mm 150mm 72 x 35 x 150mm
RS Stock No. 123-3298
BrandRS PRO
kr 1 639,50
Each
Units
+1300 °C, +1999 °F UKAS Handheld K - ±0.3 % - 2 0.1 °C, 0.2 °F Yes 74mm 39mm 170mm 74 x 39 x 170mm
RS Stock No. 123-2214
BrandRS PRO
kr 2 010,25
Each
Units
+1090 (J) °C, +1300 (N) °C, +1370 (K) °C, +1598 (E) °F, +1767 (R) °C, +1767 (S) °C, +1994 (J) °F, +1999.9 (K) °F, +1999.9 (N) °F, +1999.9 (R) °F, +1999.9 (S) °F, +400 (T) °C, +752 (T) °F, +870 (E) °C - Handheld E, J, K, N, R, S, T - ±0.05 % - 2 0.1 K Yes 72mm 35mm 150mm 72 x 35 x 150mm
RS Stock No. 123-2279
BrandRS PRO
kr 2 575,25
Each
Units
+1090 (J) °C, +1300 (N) °C, +1370 (K) °C, +1598 (E) °F, +1767 (R) °C, +1767 (S) °C, +1994 (J) °F, +1999.9 (K) °F, +1999.9 (N) °F, +1999.9 (R) °F, +1999.9 (S) °F, +400 (T) °C, +752 (T) °F, +870 (E) °C RSCAL Handheld E, J, K, N, R, S, T - ± 0.05 % + 2 (S) °C, ±0.05 % + 0.5 (E) °C, ±0.05 % + 0.5 (J) °C, ±0.05 % + 0.5 (K) °C, ±0.05 % + 0.5 (N) °C, ±0.05 % + 0.5 (T) °C, ±0.05 % + 0.9 (E) °F, ±0.05 % + 0.9 (J) °F, ±0.05 % + 0.9 (K) °F, ±0.05 % + 0.9 (N) °F, ±0.05 % + 0.9 (T) °F, ±0.05 % + 2 (R) °C, ±0.05 % + 4 (R) °F, ±0.05 % + 4 (S) °F - 2 0.1 (E) °F, 0.1 (E) °C, 0.1 (E) K, 0.1 (J) °C, 0.1 (J) K, 0.1 (J) °F, 0.1 (K) K, 0.1 (K) °C, 0.1 (K) °F, 0.1 (N) °F, 0.1 (N) K, 0.1 (N) °C, 0.1 (T) °F, 0.1 (T) °C, 0.1 (T) K, 1 (R) °F, 1 (R) °C, 1 (R) K, 1 (S) °F, 1 (S) °C, 1 (S) K Yes 72mm 35mm 150mm 72 x 35 x 150mm
RS Stock No. 446-4048
BrandRS PRO
kr 3 801,46
Each
Units
1767°C - - E, J, K, N, R, S, T - ±0.6 K - 6 0.1 °C - 148mm 67mm 190mm 148 x 67 x 190mm
RS Stock No. 136-8870
BrandRS PRO
kr 1 429,50
Each
Units
+1300 °C, +1999 °F SYSCAL Handheld K - ±0.3 % - 2 0.1 °C, 0.2 °F Yes 74mm 39mm 170mm 74 x 39 x 170mm
RS Stock No. 123-3216
BrandRS PRO
kr 864,50
Each
Units
+1300 °C, +1999 °F - Handheld K - ±1 K - 2 0.1 °C, 0.2 °F No 74mm 39mm 170mm 74 x 39 x 170mm
RS Stock No. 123-3218
BrandRS PRO
kr 1 315,74
Each
Units
+1372 °C, +2501 °F - Handheld J, K - ±0.7 K - 2 0.1 K, 0.1 °C, 0.2 °F Yes 74mm 39mm 170mm 74 x 39 x 170mm
Related Products
Using an external K-type thermocouple bead probe as ...
Description:
Using an external K-type thermocouple bead probe as a temperature sensor, this compact sized digital thermometer offer fast response and laboratory accuracy. The RS41 fully portable, offers accurate temperature indication, following National Bureau of Standards and IEC584 temperature/voltage tables for ...
Chauvin Arnoux C.A 1823 is a single-input, data ...
Description:
Chauvin Arnoux C.A 1823 is a single-input, data logging digital thermometer which allows you to log temperature readings from a single attached temperature probe. Compact and magnetised for fixed or portable use, the C.A 1823 is an accurate, versatile, long-lasting ...
Chauvin Arnoux C.A 1822 is a single-input, data ...
Description:
Chauvin Arnoux C.A 1822 is a single-input, data logging digital thermometer which allows you to log temperature readings from a single attached temperature probe. Compact and magnetised for fixed or portable use, the C.A 1822 is an accurate, versatile, long-lasting ...
Powered by 12V car cigarette lighter socket3m external, ...
Description:
Powered by 12V car cigarette lighter socket3m external, weather proof temperature sensor. Accuracy of ±1°C between the operating temperature of 0°C to +40°C (resolution 0.5°C)Audible and visual alarms to warn of hazardous road conditions (icy/slippery)°C/°F selectable. Backlit LC display.