Better World
Schneider Electric LC1D Series Contactor, 48 V dc Coil, 3-Pole, 25 A, 11 kW, 3NO, 690 V ac
- RS Stock No.:
- 608-9582
- Mfr. Part No.:
- LC1D25ED
- Brand:
- Schneider Electric
1 In stock for same day dispatch
Added
Price Each
Kr. 1 699,50
(exc. VAT)
Kr. 2 124,38
(inc. VAT)
Units | Per unit |
1 + | Kr. 1 699,50 |
Better World
Our Better World range features products that make it easy for you to make a greener product choice you can trust. Click here to find out more.
- RS Stock No.:
- 608-9582
- Mfr. Part No.:
- LC1D25ED
- Brand:
- Schneider Electric
Legislation and Compliance
Product Details
Schneider Electric LC1D TeSys D Contactors
TeSys D Contactors from Schneider Electric combine long mechanical and electrical life to offer a high reliable contactor. The range has been designed for integration in control systems and can be used to create motor starters for any type of application. The TeSys D contactors offer quick simple setup while maintaining compliance with international standards.
Features and Benefits
Built-in auxiliary contacts for added switching capability
Screw connections: IP20 finger-safe terminals with both North American and International terminal markings
Can be panel mounted with screws or DIN Rail mounted
Bidirectional peak limiting diode suppressor to protect the coil
Easily installed accessories
Flexible control circuit to suit a wide range of applications
Screw connections: IP20 finger-safe terminals with both North American and International terminal markings
Can be panel mounted with screws or DIN Rail mounted
Bidirectional peak limiting diode suppressor to protect the coil
Easily installed accessories
Flexible control circuit to suit a wide range of applications
What does the utilisation category AC1 and AC3 mean for the TeSys contactors?
Contactor utilisation categories define the current making and breaking values, based on the type of load to be controlled and the operating cycle conditions.
- AC-1: This applies to all AC devices with a power factor of at least 0.95. Example of use: resistive load, heating, distribution.
- AC-3: This applies to squirrel cage motors where breaking occurs while the motor is running. Example of use: all squirrel cage motors, lifts, escalators, conveyors, bucket elevators, compressors, pumps, mixers, air conditioning units.
What accessories are available?
Auxiliary contact blocks with serrated wiping action
Front mount dust tight auxiliary contact blocks
Pneumatic time delay blocks
Transient voltage surge suppressors
Interface modules and electronic timers
Mechanical latching blocks
Front mount dust tight auxiliary contact blocks
Pneumatic time delay blocks
Transient voltage surge suppressors
Interface modules and electronic timers
Mechanical latching blocks
Is the TeSys D range a double break pole type contactor?
Yes the Tesys D range uses linear translation movement that provides double breaking of the poles.
Schneider Electric Contactor, 690V AC Contact Voltage Rating, 6kV Rated Impulse Withstand Voltage - TeSys D Series - LC1D25ED
To switch things up in your power management system, reach for this contactor from Scheider Electric. It's a fast-acting option that turns heavy-duty engines, HVAC systems or electrical equipment on and off at speeds up to 16ms. The device can match the pace of busy applications by switching up to 3600 times per hour even in demanding +60°C temperatures. With a lifespan of 30 million cycles, this component won't quit, so you get reliable, long-lasting service. You can customise it with up to two auxiliary contacts to suit your setup like a glove.
• Wide temperature range of -5°C to +60°C for use in demanding settings
• Compatible with a standard DIN rail, so mounting is speedy
• IP20 rating shows it's touch-proof and safe to handle
• Bidirectional peak limiting diode suppressor protects the coil from surge damage
• Compatible with a standard DIN rail, so mounting is speedy
• IP20 rating shows it's touch-proof and safe to handle
• Bidirectional peak limiting diode suppressor protects the coil from surge damage
Applications
• Manufacturing industry
• Construction plants
• Mining facilities
• HVAC systems
• Construction plants
• Mining facilities
• HVAC systems
What type of auxiliaries can I add to this contactor?
You can beef up the power and capabilities of this product with an auxiliary contactor (394-9908), a time delay unit (394-9835) or a mechanical latch block (400-2016) to suit your setup's needs.
Specifications
Attribute | Value |
---|---|
Coil Voltage | 48 V dc |
Number of Poles | 3 |
Contact Voltage Rating | 690 V ac |
Contact Current Rating | 25 A |
Series | LC1D |
Power Rating | 11 kW |
Range | TeSys D |
Function | Motor Control |
Normal State Configuration | 3NO |
Auxiliary Contact Configuration | 1NO + 1NC |
Number Of Auxiliary Contacts | 2 |
Terminal Type | Screw |
Length | 85mm |
Depth | 99mm |
Better World Product | Yes |
Better World Verification | Green Premium |
Maximum Operating Temperature | +60°C |
Control Voltage | 48 V dc |
Pole and Throw Configuration | 3P |
Minimum Operating Temperature | -5°C |
Mounting Style | DIN Rail Mount, Plate |
Input Current | 25A |