Product Details

Fluke AC/DC Current Clamp

The Fluke i30s AC/DC current clamp has a current rating of 300AAC and 450ADC. It is a state of the art device used with oscilloscopes and digital multimeters for accurate non-intrusive measurement and complex waveform currents.

Features and Benefits

Output cable and connections :safety BNC connector supplied with safety 4mm adapter
Power supply is a 9V alkaline
Low battery indicator
Zero adjustment
Output sensitivity: 10mV/A (40A) to mV/A (400A)
Resolution: ±50mA (40A) to ±100mA (400A)
Load impedance is greater10kohms and 100pF
Frequency range (small signal): DC to 20kHz (-3dB)
Phase shift below 1kHz, less than 2 degrees
Temperature coefficient: ±0.1% of reading /°C

Applications

Inverters
Switch mode power supplies
Industrial controllers
Automotive diagnostics
Other applications requiring current measurements
Waveform analysis

Certifications

EN 61010-1: 2001
EN 61010-2-032: 2002
EN 61010-031: 2002
300Vrms CAT III safety rated
EN 61236 :1998 +A1, A2, and A3
IEC 61326-1
CE certified
cCSAus certified

Specifications
Attribute Value
Probe Type AC/DC
Calibrated UKAS
Maximum Conductor Size 19mm
Safety Category CAT III 300 V
Safety Category Level CAT III
Model Number p I310S
Best Accuracy ±1% + 300 mA
Safety Category Voltage 300V
Bandwidth 1kHz
5 In stock for delivery within 3-5 working days
Price Each
kr 4 006,00
(exc. VAT)
kr 5 007,50
(inc. VAT)
Units
Per unit
1 +
kr 4 006,00
Not available for next day delivery
Related Products
The CA8334B combines the functions of a powerful ...
Description:
The CA8334B combines the functions of a powerful electrical interference analyser with power quality measurement.Robust, portable container; thanks to its large display the user can clearly see all the voltage and current waveforms, as well as vectorial diagrams for each ...
The Tektronix current probes are created for the ...
Description:
The Tektronix current probes are created for the permanent or semi-permanent in-circuit installation. Each probe consists of a current transformer and an interconnecting cable. The current transformers have a small hole to pass a current-carrying conductor during circuit assembly. Approximate ...
Using hybrid technology that includes a Hall-effect sensor ...
Description:
Using hybrid technology that includes a Hall-effect sensor and an AC current transformer, the probes provide accurate measurement of DC,or AC currents up to 500 Arms (for model N2780A) or DC–100 MHz (for model N2783A), without breaking into the circuit. ...
Dual range a.c. current clamp nominal measuring ranges ...
Description:
Dual range a.c. current clamp nominal measuring ranges 0.1A to 20A a.c. and 0.5A to 200A a.c.Safe, non intrusive current measurement40Hz to 10k. Hz bandwidth. Ergonomic jaw design for measurement where access is difficult and allows 'hooking' onto the cable. ...