HOBUT DIN Rail Mounted Circuit Transformer, -30 → +85 °C, 400:5

  • RS Stock No. 331-496
  • Mfr. Part No. CT143M400/5-5/0.5-001
  • Brand HOBUT
Technical Reference
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): GB
Product Details

Compact Busbar/Base Mounting Current Transformers - Series 14

A range of compact moulded case current transformers suitable for primary currents from 25A to 500A with built-in sealable terminal covers. For transforming various primary currents into 5A standard secondary current using 20mm or 30mm busbars or 24mm cables.

DIN rail mounting clip supplied
Built-in sealable terminal covers
Mounting feet and busbar screws supplied
Narrow width
Dimensions: H70 x W49 x D30mm
Conforms to IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1
Rated system voltage: 0.72/3kV
Ambient temperature range: -30 to 85°C
Continuous current: 1.2 x rated current

Current Transformers

Specifications
Attribute Value
Current Ratio 400:5
Inner Diameter 24mm
Transformer Type DIN Rail Mounted
Overall Height 70mm
Overall Width 49mm
Overall Depth 45mm
Minimum Temperature -30°C
Maximum Temperature +85°C
42 In stock for delivery within 1 working days
Price Each
kr 194,51
(exc. VAT)
kr 243,14
(inc. VAT)
Units
Per unit
1 - 4
kr 194,51
5 - 9
kr 188,73
10 +
kr 180,99
Related Products
Power consumption 2.5VA, 50/60Hz. Accuracy class 120 or ...
Description:
Power consumption 2.5VA, 50/60Hz. Accuracy class 120 or 30mm busbar mounting. Suitable for circular conductors 24 aperture. Maximum aperture for bar conductors 30x10mm (type 6)Operating temperature range –30 to +85°CSecondary terminals M5 studs with lock washers, nuts and terminal cover. ...
Miniature three phase current transformers suitable for primary ...
Description:
Miniature three phase current transformers suitable for primary ranges from 100A-250A with 5A secondary.For installation onto cables or 21mm maximum busbars.The products have an overall width of 105mm allowing installation directly on top of moulded case circuit breakers.,Supplied with terminal ...
Set consisting of a 1 A measuring transducer ...
Description:
Set consisting of a 1 A measuring transducer and a Rogowski coil with signal line. Length of Rogowski coil: 600 mm, diameter: 190 mm. Length of signal line: 10 m. The Rogowski coil measures the AC current of busbars and ...
Set consisting of a 4-way signal conditioner with ...
Description: