ABB Auxiliary Contact Block, 4 Contact, 1 NO/3 NC, CA5-31ERT, Front, 4 A, 1SBN010042R1031
- RS Stock No.:
- 259-6027
- Mfr. Part No.:
- 1SBN010042R1031
- Brand:
- ABB
Subtotal (1 box of 2 units)*
Kr. 896,62
(exc. VAT)
Kr. 1 120,78
(inc. VAT)
FREE delivery for online orders over 750,00 kr
Stocked by manufacturer
- Ready to ship from 18 June 2026
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Box(es) | Per Box | Per unit* |
|---|---|---|
| 1 + | Kr. 896,62 | Kr. 448,31 |
*price indicative
- RS Stock No.:
- 259-6027
- Mfr. Part No.:
- 1SBN010042R1031
- Brand:
- ABB
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | ABB | |
| Number of Contacts | 4 | |
| Product Type | Auxiliary Contact Block | |
| Normal State Configuration | 1 NO/3 NC | |
| Series | CA5-31ERT | |
| Contact Current | 4A | |
| Mount Type | Front | |
| Terminal Type | Ring Tongue Terminal | |
| Operational Current Ie | 2A | |
| Mounting Location | Front | |
| Rated Insulation Voltage Ui | 500V | |
| Standards/Approvals | UL/CSA A600 Q300 Pilot Duty, EU Directive 2011/65/EU (RoHS Status) | |
| Select all | ||
|---|---|---|
Brand ABB | ||
Number of Contacts 4 | ||
Product Type Auxiliary Contact Block | ||
Normal State Configuration 1 NO/3 NC | ||
Series CA5-31ERT | ||
Contact Current 4A | ||
Mount Type Front | ||
Terminal Type Ring Tongue Terminal | ||
Operational Current Ie 2A | ||
Mounting Location Front | ||
Rated Insulation Voltage Ui 500V | ||
Standards/Approvals UL/CSA A600 Q300 Pilot Duty, EU Directive 2011/65/EU (RoHS Status) | ||
- COO (Country of Origin):
- CZ
ABB CA5-31ERT Series Auxiliary Contact Block, 4A Contact Current, 690V Contact Voltage - 1SBN010042R1031
This auxiliary contact Block provides additional switching contacts to complement control devices in electrical systems. Designed for front mounting, it integrates with control panels and contactor assemblies to expand contact configurations without altering primary devices. The unit supports mixed normally open and normally closed arrangements for auxiliary signalling and interlock functions.
Features and Benefits:
• 4P configuration delivers four contact poles for expanded control
• 3NO/1NC arrangement enables combined signalling and safety interlocks
• Screw Terminal connection simplifies secure wiring terminations
• Rated insulation voltage 690V allows use in high-voltage control circuits
• Contact current 4A supports moderate auxiliary load switching
• Operational current Ie 2A limits continuous pilot duty switching to specified level
• 3NO/1NC arrangement enables combined signalling and safety interlocks
• Screw Terminal connection simplifies secure wiring terminations
• Rated insulation voltage 690V allows use in high-voltage control circuits
• Contact current 4A supports moderate auxiliary load switching
• Operational current Ie 2A limits continuous pilot duty switching to specified level
Applications
• Suitable for remote signalling in industrial contactor panels
• Ideal for interlock arrangements in motor control systems
• Used with PLC inputs for status feedback of power devices
• Can be used for auxiliary switching in automation cabinets
• Suitable for replacing worn auxiliary contacts in existing assemblies
• Ideal for interlock arrangements in motor control systems
• Used with PLC inputs for status feedback of power devices
• Can be used for auxiliary switching in automation cabinets
• Suitable for replacing worn auxiliary contacts in existing assemblies
What mounting method is required for installation?
It is designed for front mounting so it attaches to the face of compatible control devices to align contacts and maintain panel accessibility.
What Terminal style is provided for wiring?
Connections are MADE via screw terminals to ensure firm conductor retention and straightforward field wiring.
How does the contact arrangement support control logic?
The mixed configuration of three normally open and one normally closed contact permits combined signalling and fail-safe circuits within a Compact auxiliary block.
What duty ratings relate to pilot applications?
The contact blocks operational current is specified at 2A, with switching capacity for contact current up to 4A, aligning it with typical pilot duty requirements.
Which electrical insulation level does it meet for application planning?
The unit is specified with a rated insulation voltage of 690V, informing selection for higher-voltage control environments.
Related links
- ABB Auxiliary Contact Block 3 NO/1 NC Front 690V, 1SBN010040R1113
- ABB Auxiliary Contact Block 1 NO/3 NC Front 1SBN010042R1131
- ABB Auxiliary Contact Block 4 NC Front 690V, 1SBN010042R1040
- ABB Auxiliary Contact Block 1 NC Front 690V, 1SBN010010R1001
- ABB Auxiliary Contact Block 4 NC Front 690V, 1SBN010140R1004
- ABB Auxiliary Contact Block 2 NC/2 NO Front 1SBN010042R1122
- ABB Auxiliary Contact Block 4 NC Front 690V, 1SBN010140R1104
- ABB Auxiliary Contact Block 2 NC/2 NO DIN 690V, 1SBN010140R1022
