ABB Auxiliary Contact Block, 4 Contact, 2 NC/2 NO, CA4-22M, Front, 6 A, 690V, 1SBN010140R1122
- RS Stock No.:
- 260-3764
- Mfr. Part No.:
- 1SBN010140R1122
- Brand:
- ABB
Subtotal (1 unit)*
Kr. 233,98
(exc. VAT)
Kr. 292,48
(inc. VAT)
FREE delivery for online orders over 750,00 kr
In Stock
- Plus 15 unit(s) shipping from 04 May 2026
- Plus 1 unit(s) shipping from 04 May 2026
- Plus 23 unit(s) shipping from 15 May 2026
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
|---|---|
| 1 + | Kr. 233,98 |
*price indicative
- RS Stock No.:
- 260-3764
- Mfr. Part No.:
- 1SBN010140R1122
- Brand:
- ABB
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | ABB | |
| Product Type | Auxiliary Contact Block | |
| Number of Contacts | 4 | |
| Normal State Configuration | 2 NC/2 NO | |
| Series | CA4-22M | |
| Mount Type | Front | |
| Contact Current | 6A | |
| Terminal Type | Screw | |
| Pole and Throw Configuration | 4P | |
| Contact Voltage | 690V | |
| Mounting Location | Front | |
| Mechanical Durability | 3600Cycles | |
| Rated Insulation Voltage Ui | 690V | |
| Operational Current Ie | 6A | |
| Standards/Approvals | IEC 60947-5-1, UL/CSA, VDE 0110 (Gr. C) | |
| Select all | ||
|---|---|---|
Brand ABB | ||
Product Type Auxiliary Contact Block | ||
Number of Contacts 4 | ||
Normal State Configuration 2 NC/2 NO | ||
Series CA4-22M | ||
Mount Type Front | ||
Contact Current 6A | ||
Terminal Type Screw | ||
Pole and Throw Configuration 4P | ||
Contact Voltage 690V | ||
Mounting Location Front | ||
Mechanical Durability 3600Cycles | ||
Rated Insulation Voltage Ui 690V | ||
Operational Current Ie 6A | ||
Standards/Approvals IEC 60947-5-1, UL/CSA, VDE 0110 (Gr. C) | ||
ABB CA4-22M Series Auxiliary Contact Block, 6A Contact Current, 690V Rated Insulation Voltage - 1SBN010140R1122
This auxiliary contact Block provides additional switching contacts for control circuits in industrial electrical systems. Designed for front mounting, it extends a contactors signalling capability with a four-contact arrangement suited to monitoring and interlocking tasks in automation and control panels.
Features and Benefits:
• Four-contact configuration gives simultaneous signalling and interlock capability
• Rated for 6A continuous operation supports modest control loads
• 690V insulation rating enables application across high-voltage control circuits
• Screw terminals allow secure, low-resistance conductor connections
• Mechanical endurance of 3600 cycles ensures predictable switching life
• Complies with recognised electrical standards for safe integration
• Rated for 6A continuous operation supports modest control loads
• 690V insulation rating enables application across high-voltage control circuits
• Screw terminals allow secure, low-resistance conductor connections
• Mechanical endurance of 3600 cycles ensures predictable switching life
• Complies with recognised electrical standards for safe integration
Applications
• Suitable for adding auxiliary contacts to contactors in motor control
• Ideal for interlock circuits in automated machinery control panels
• Used with distributed control systems for status feedback loops
• Can be used for signalling and alarm circuits in electrical distribution
• Ideal for interlock circuits in automated machinery control panels
• Used with distributed control systems for status feedback loops
• Can be used for signalling and alarm circuits in electrical distribution
How many contacts are available for wiring multiple circuits?
It provides four switching elements arranged as two normally closed and two normally open contacts to manage separate control paths.
What mounting method is required to fit it to a contactor?
It is designed for front-mounted installation to couple directly with the main switching device at the access face.
What Terminal type is fitted for conductor attachment?
Termination is by screw-style terminals to secure conductors and maintain electrical continuity under vibration.
Which operational current should be observed when integrating into control loops?
The contact rating is 6A and should be treated as the maximum continuous switching current for connected loads.
Which approvals support its use in industrial installations?
It meets multiple international standards and approvals relevant to control auxiliary devices, permitting use within regulated electrical systems.
Related links
- ABB Auxiliary Contact 2 NC/2 NO Front 690V ac, 1SBN010140R1122 CA4-22M
- ABB Auxiliary Contact Block 2 NC/2 NO DIN 690V, 1SBN010140R1222
- ABB Auxiliary Contact Block 2 NC/2 NO DIN 690V, 1SBN010140R1022
- ABB Auxiliary Contact 2 NC/2 NO Front 600 V dc 1SBN010140R1322 CA4-22U
- ABB Auxiliary Contact 2 NC/2 NO Front 690V ac, 1SBN010140R1222 CA4-22N
- ABB Auxiliary Contact Block 1 NO/1 NC DIN 690V, 1SBN010111R1001
- ABB Auxiliary Contact Block 1 NO/1 NC Front 690V, 1SBN010155R1011
- ABB Auxiliary Contact 2 NC/2 NO Front 230V ac, 1SBN010040R1122 - CA5-22M