Belden 1855ENH Series, 1000 m, RG59 Coaxial Coaxial Cable 75 Ω, Green, Terminated
- RS Stock No.:
- 631-722
- Mfr. Part No.:
- 1855ENH.001000
- Brand:
- Belden
Subtotal (1 reel of 1000 metres)*
Kr. 41 110,44
(exc. VAT)
Kr. 51 388,05
(inc. VAT)
Stock information currently inaccessible - Please check back later
Reel(s) | Per Reel | Per Metre* |
|---|---|---|
| 1 + | Kr. 41 110,44 | Kr. 41,11 |
*price indicative
- RS Stock No.:
- 631-722
- Mfr. Part No.:
- 1855ENH.001000
- Brand:
- Belden
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Belden | |
| Terminated/Unterminated | Terminated | |
| Product Type | Coaxial Cable | |
| Coaxial Type | RG59 | |
| American Wire Gauge | 22AWG | |
| Voltage | 75V | |
| Outside Diameter | 4.45mm | |
| Characteristic Impedance | 75Ω | |
| Minimum Operating Temperature | 30°C | |
| Conductor Type | Solid | |
| Attenuation | 1.7 to 70.2 dB/100m | |
| Maximum Operating Temperature | 70°C | |
| Cable Length | 1000m | |
| Standards/Approvals | IEC 60332-1-2, UKCA, EN 50117-1, IEC 61034-2, EU CE, IEC 60332-3-24, CEI 20-22-3, IEC 60754-1/-2, IEC 62821-1 | |
| Jacket Colour | Green | |
| Fire Behaviour | IEC 60332-1-2, CEI 20-35/1 | |
| Conductor Material | Bare Copper | |
| Series | 1855ENH | |
| Jacket Material | Low Smoke Zero Halogen | |
| Select all | ||
|---|---|---|
Brand Belden | ||
Terminated/Unterminated Terminated | ||
Product Type Coaxial Cable | ||
Coaxial Type RG59 | ||
American Wire Gauge 22AWG | ||
Voltage 75V | ||
Outside Diameter 4.45mm | ||
Characteristic Impedance 75Ω | ||
Minimum Operating Temperature 30°C | ||
Conductor Type Solid | ||
Attenuation 1.7 to 70.2 dB/100m | ||
Maximum Operating Temperature 70°C | ||
Cable Length 1000m | ||
Standards/Approvals IEC 60332-1-2, UKCA, EN 50117-1, IEC 61034-2, EU CE, IEC 60332-3-24, CEI 20-22-3, IEC 60754-1/-2, IEC 62821-1 | ||
Jacket Colour Green | ||
Fire Behaviour IEC 60332-1-2, CEI 20-35/1 | ||
Conductor Material Bare Copper | ||
Series 1855ENH | ||
Jacket Material Low Smoke Zero Halogen | ||
Belden 1855ENH Series Coaxial Cable, 1000m Cable Length, 75Ω Characteristic Impedance - 1855ENH.001000
This coaxial cable provides a screened signal transmission solution for video and data links in industrial and building installations, designed for environments requiring low halogen emissions and enhanced fire performance. It is supplied on a 1000m reel with a green outer sheath and supports standard 75V operation at temperatures up to 70°C.
Features and Benefits:
• 75Ω characteristic impedance for stable signal integrity
• 22AWG solid bare copper conductor for consistent conductivity
• LSZH jacket reduces toxic fumes during combustion
• Attenuation range 1.7–70.2dB/100m for predictable loss planning
• Terminated delivery simplifies installation on site
• Rated to operate between −30°C and 70°C for temperature resilience
• 22AWG solid bare copper conductor for consistent conductivity
• LSZH jacket reduces toxic fumes during combustion
• Attenuation range 1.7–70.2dB/100m for predictable loss planning
• Terminated delivery simplifies installation on site
• Rated to operate between −30°C and 70°C for temperature resilience
Applications
• Suitable for CCTV installations conforming to EN 50117-1 requirements
• Ideal for signal distribution in automation and control panels
• Used with analogue video links and legacy broadcast equipment
• Can be used for low-voltage monitoring runs in electrical installations
• Ideal for signal distribution in automation and control panels
• Used with analogue video links and legacy broadcast equipment
• Can be used for low-voltage monitoring runs in electrical installations
What conductor type is used and how does it affect connections?
The conductor is a solid bare copper core which offers stable electrical contact and simplified termination for compression or crimp fittings.
How does the jacket material influence cable routing in confined spaces?
The low smoke zero halogen sheath emits minimal corrosive gases and smoke, improving safety in enclosed areas and reducing risk to sensitive electronics during a fire.
Which standards address its flame and smoke behaviour?
It meets IEC 60332-1-2 and related IEC tests for flame propagation and IEC 60754-1/-2 and IEC 61034-2 for gas and smoke emissions.
What electrical operating limits should installers observe?
The cable is rated to 75V and exhibits the provided attenuation characteristics for planning run lengths and signal conditioning.
Related links
- Belden 1855ENH Series RG59 Coaxial SDI Coaxial Cable 75 Ω, Unterminated
- Belden 1855ENH Series RG59 Coaxial SDI Coaxial Cable 75 Ω Unterminated
- Belden 1855ENH Series RG59/U Coaxial SDI Coaxial Cable 75 Ω, Unterminated
- Belden 4855ANH Series RG59 Coaxial SDI Coaxial Cable 75 Ω, Unterminated
- Belden 70084NH Series RG11 Coaxial SDI Coaxial Cable 75 Ω Unterminated
- Belden Coax Plug 1000 m Black, Terminated
- Belden H155A01 Series H155 Coaxial Coaxial Cable 50 Ω Unterminated
- Belden 8723NH Series Twisted & Multipair Industrial Cable 1000 m Low Smoke Zero Halogen