Recom R12P DC/DC Converter, 5V dc/ 200 mA, 12V dc Input, 10.8V Input 2 W, Through Hole, 85 °C Max Temp -40 °C Min Temp,

Bulk discount available

Subtotal (1 tube of 25 units)*

Kr. 6 756,44

(exc. VAT)

Kr. 8 445,55

(inc. VAT)

Add to Basket
Select or type quantity
Temporarily out of stock
  • Shipping from 07 September 2026
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.

Tube(s)
Per Tube
Per unit*
1 - 4Kr. 6 756,44Kr. 270,258
5 - 9Kr. 6 553,77Kr. 262,151
10 - 24Kr. 6 351,10Kr. 254,044
25 - 49Kr. 6 148,32Kr. 245,933
50 +Kr. 5 945,67Kr. 237,827

*price indicative

RS Stock No.:
166-6563
Mfr. Part No.:
R12P205D/R8
Brand:
Recom
Find similar products by selecting one or more attributes.
Select all

Brand

Recom

Output Voltage 1

5V dc

Product Type

DC/DC Converter

Minimum Input Voltage

10.8V

Maximum Input Voltage

12V dc

Output Current 1

200mA

Output Current 2

200mA

Mount Type

Through Hole

Output Voltage 2

-5V dc

Number of Outputs

2

MTBF

2113000h

Number of Pins

7

Isolation Voltage

8kV dc

Maximum Output Power

2W

Package Type

SIP

Standards/Approvals

No

Length

19.5mm

Series

R12P

Depth

12.5mm

Minimum Operating Temperature

-40°C

Efficiency

88%

Maximum Operating Temperature

85°C

2 W Unregulated DC to DC Converters, Medically Approved, RxxP2xx/R8 Series


These 2W unregulated SIP 7 DC to DC converters are available with single or dual outputs and are certified to UL/CSA-60950 and UL/CSA- 60601 making them ideal for medical and safety applications. These DC to DC converters also have reinforced isolation and are EN61010-1 certified for lab equipment safety.

Compact SIP7 package

EN60601-1 certified for medical applications

EN61010-1 certified for measurement, control and laboratory use

Reinforced isolation of 8kVdc

Efficiency of up to 88%

Unique transformer system (patent pending)

Short circuit protection

Note

MTBF to MIL-HDBK 217F (25°C)
Derate output when operating temperature is above 85°C

Approvals

UL, CSA

Standards

EN-60950-1, UL 60950-1, CSA 60950-1, EN-60601-1, UL 60601-1, CSA 60601-1, EN-61010-1

Related links