TRACOPOWER THN 30WIR Isolated DC-DC Converter, 24V dc/ 625 mA, 75V dc Input, 18V Input 30 W, PCB, 65 °C Max Temp -40 °C
- RS Stock No.:
- 249-7370
- Mfr. Part No.:
- THN 30-4825WIR
- Brand:
- TRACOPOWER
Bulk discount available
Subtotal (1 tube of 10 units)*
Kr. 7 999,99
(exc. VAT)
Kr. 9 999,99
(inc. VAT)
FREE delivery for online orders over 750,00 kr
In Stock
- Plus 14 unit(s) shipping from 27 April 2026
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Tube(s) | Per Tube | Per unit* |
|---|---|---|
| 1 - 4 | Kr. 7 999,99 | Kr. 799,999 |
| 5 - 9 | Kr. 7 759,93 | Kr. 775,993 |
| 10 - 24 | Kr. 7 520,07 | Kr. 752,007 |
| 25 - 49 | Kr. 7 200,01 | Kr. 720,001 |
| 50 + | Kr. 6 879,84 | Kr. 687,984 |
*price indicative
- RS Stock No.:
- 249-7370
- Mfr. Part No.:
- THN 30-4825WIR
- Brand:
- TRACOPOWER
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | TRACOPOWER | |
| Output Voltage 1 | 24V dc | |
| Product Type | Isolated DC-DC Converter | |
| Maximum Input Voltage | 75V dc | |
| Minimum Input Voltage | 18V | |
| Output Current 1 | 625mA | |
| Output Current 2 | -625mA | |
| Mount Type | PCB | |
| Output Voltage 2 | 24V dc | |
| Input Ratio | 4:1 | |
| Number of Outputs | 2 | |
| MTBF | 420800h | |
| Output Voltage Adjustment Range | 20 % | |
| Number of Pins | 6 | |
| Isolation Voltage | 2.25kV dc | |
| Maximum Output Power | 30W | |
| Package Type | Metal | |
| Standards/Approvals | RoHS | |
| Length | 25.4mm | |
| Series | THN 30WIR | |
| Depth | 9.9mm | |
| Width | 25.4mm | |
| Minimum Operating Temperature | -40°C | |
| Efficiency | 92% | |
| Maximum Operating Temperature | 65°C | |
| Select all | ||
|---|---|---|
Brand TRACOPOWER | ||
Output Voltage 1 24V dc | ||
Product Type Isolated DC-DC Converter | ||
Maximum Input Voltage 75V dc | ||
Minimum Input Voltage 18V | ||
Output Current 1 625mA | ||
Output Current 2 -625mA | ||
Mount Type PCB | ||
Output Voltage 2 24V dc | ||
Input Ratio 4:1 | ||
Number of Outputs 2 | ||
MTBF 420800h | ||
Output Voltage Adjustment Range 20 % | ||
Number of Pins 6 | ||
Isolation Voltage 2.25kV dc | ||
Maximum Output Power 30W | ||
Package Type Metal | ||
Standards/Approvals RoHS | ||
Length 25.4mm | ||
Series THN 30WIR | ||
Depth 9.9mm | ||
Width 25.4mm | ||
Minimum Operating Temperature -40°C | ||
Efficiency 92% | ||
Maximum Operating Temperature 65°C | ||
RoHS Status: Exempted
- COO (Country of Origin):
- TW
TRACOPOWER THN 30WIR Series Isolated DC-DC Converter, -24 to 24V DC Output Voltage, 30W Power Rating - THN 30-4825WIR
This isolated DC-DC converter is designed for applications that require high durability in rigorous environments. With an output power of 30W and a broad input voltage range of 18 to 75V DC, it meets the strict requirements of industrial automation and railway applications. Its compact encapsulation enhances thermal and mechanical robustness, making it suitable for challenging conditions.
Features & Benefits
• Delivers a 30W output for various industrial uses
• Operates with up to 92% conversion efficiency
• Supports a wide input voltage range for versatility
• Provides 2250V DC isolation for added safety
• Includes short-circuit and overvoltage protection
• Features remote control functionality for flexible management
Applications
• Suitable for railway electronics requiring dependable power
• Ideal for PCB mounting in automation systems
• Applicable in situations needing a resilient power supply
• Supports control systems with precise voltage regulation
• Functions effectively in environments with high electromagnetic interference
What are the temperature limits for operation?
The unit operates effectively in ambient temperatures from -40 to +80°C, ensuring dependability in various conditions.
How can I adjust the output voltage?
Output voltage can be adjusted within -10% to +20% using an external trim resistor, allowing for customised voltage levels.
Is it suitable for use in electric transportation systems?
Yes, it is certified for railway applications, making it appropriate for electric transportation systems and similar settings.
What considerations should I take when mounting?
Ensure sufficient space for natural convection cooling and that the mounting surface can withstand operating temperatures.
Related links
- TRACOPOWER THN 30WIR Isolated DC-DC Converter 75V dc Input PCB, 65 °C Max Temp -40 °C
- TRACOPOWER THN 30WIR Isolated DC-DC Converter 75V dc Input PCB, 65 °C Max Temp -40 °C
- TRACOPOWER THN 30WIR Isolated DC-DC Converter 75V dc Input PCB, 65 °C Max Temp -40 °C
- TRACOPOWER THN 30WIR Isolated DC-DC Converter 75V dc Input PCB, 65 °C Max Temp -40 °C
- TRACOPOWER THN 30WIR Isolated DC-DC Converter 75V dc Input PCB, 65 °C Max Temp -40 °C
- TRACOPOWER THN 30WIR Isolated DC-DC Converter 160V dc Input PCB, 65 °C Max Temp -40 °C
- TRACOPOWER THN 30WIR Isolated DC-DC Converter 75V dc Input PCB, 65 °C Max Temp -40
- TRACOPOWER THN 30WIR Isolated DC-DC Converter 75V dc Input PCB, 65 °C Max Temp -40