HellermannTyton Connectivity CA Cat6 Cat6 Cable, 305 m, Purple, Unshielded Unscreened Low Smoke Fire Retardant Zero
- RS Stock No.:
- 351-801
- Mfr. Part No.:
- CA202
- Brand:
- HellermannTyton Connectivity
Subtotal (1 box of 305 metres)*
Kr. 2 802,58
(exc. VAT)
Kr. 3 503,22
(inc. VAT)
FREE delivery for online orders over 750,00 kr
In Stock
- Plus 10 unit(s) shipping from 11 May 2026
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Box(es) | Per Box | Per Metre* |
|---|---|---|
| 1 + | Kr. 2 802,58 | Kr. 9,189 |
*price indicative
- RS Stock No.:
- 351-801
- Mfr. Part No.:
- CA202
- Brand:
- HellermannTyton Connectivity
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | HellermannTyton Connectivity | |
| Product Type | Cat6 Cable | |
| Series | CA | |
| Cable Length | 305m | |
| LAN Category | Cat6 | |
| Shield Type | Unshielded | |
| Screened/Unscreened | Unscreened | |
| Conductor Type | Solid | |
| Jacket Colour | Purple | |
| Jacket Material | Low Smoke Fire Retardant Zero Halogen | |
| Minimum Operating Temperature | -20°C | |
| Maximum Operating Temperature | 60°C | |
| Standards/Approvals | BS EN 50288-10-1, C& UKCA, ANSI/TIA/EIA 568-C.2, IEC 61156-5, IEC 60332-1, IEC 61034, IEC 60332-3-24, BS EN 50173, IEC 60754-2, ISO 11801:2002 | |
| Cable CSA | 23AWG | |
| Fire Behaviour | LSHF-FR (FRNC, LSZH, B2ca, S1a | |
| Conductor Material | Copper | |
| Number of Cores | 4 | |
| Voltage | 1000V | |
| Outside Diameter | 6.1mm | |
| Select all | ||
|---|---|---|
Brand HellermannTyton Connectivity | ||
Product Type Cat6 Cable | ||
Series CA | ||
Cable Length 305m | ||
LAN Category Cat6 | ||
Shield Type Unshielded | ||
Screened/Unscreened Unscreened | ||
Conductor Type Solid | ||
Jacket Colour Purple | ||
Jacket Material Low Smoke Fire Retardant Zero Halogen | ||
Minimum Operating Temperature -20°C | ||
Maximum Operating Temperature 60°C | ||
Standards/Approvals BS EN 50288-10-1, C& UKCA, ANSI/TIA/EIA 568-C.2, IEC 61156-5, IEC 60332-1, IEC 61034, IEC 60332-3-24, BS EN 50173, IEC 60754-2, ISO 11801:2002 | ||
Cable CSA 23AWG | ||
Fire Behaviour LSHF-FR (FRNC, LSZH, B2ca, S1a | ||
Conductor Material Copper | ||
Number of Cores 4 | ||
Voltage 1000V | ||
Outside Diameter 6.1mm | ||
- COO (Country of Origin):
- SK
HellermanTyton Cat6 Cable, 305m Cable Length, Purple Jacket - CA202
This cat6 cable is a purple, low-smoke zero-halogen U/UTP data cable supplied on a 305m box reel for structured cabling in commercial and industrial installations. It is intended for horizontal, riser and campus links supporting Ethernet, Gigabit and Power over Ethernet applications and is suitable for use where a flame-retardant B2ca-rated sheath is required.
Features & Benefits
• 23AWG solid copper conductor gives consistent signal integrity and low loss
• Characteristic impedance 100Ω ensures matched transmission across 1–100MHz
• Test voltage 1000V provides insulation stress verification during commissioning
• Low smoke zero halogen sheath B2ca,S1a,d1,a1 reduces toxic emissions in fire
• Nominal propagation velocity ≈67% improves timing predictability in long links
• Characteristic impedance 100Ω ensures matched transmission across 1–100MHz
• Test voltage 1000V provides insulation stress verification during commissioning
• Low smoke zero halogen sheath B2ca,S1a,d1,a1 reduces toxic emissions in fire
• Nominal propagation velocity ≈67% improves timing predictability in long links
**Applications**
• Suitable for structured cabling in factory automation networks
• Ideal for PoE and PoE+ distribution to control devices and sensors
• Used for gigabit Ethernet backbones in plant and building risers
• Can be used with Category6 patch panels and outlets for channel links
• Suitable for campus and horizontal cabling where low-smoke sheath required
• Ideal for PoE and PoE+ distribution to control devices and sensors
• Used for gigabit Ethernet backbones in plant and building risers
• Can be used with Category6 patch panels and outlets for channel links
• Suitable for campus and horizontal cabling where low-smoke sheath required
What conductor and pair construction should I expect for termination?
The cable uses 23AWG solid copper conductors with four twisted pairs and polyethylene insulation, arranged Blue/White-Blue, Orange/White-Orange, Green/White-Green, Brown/White-Brown for standard pair identification.
What mechanical limits apply during installation?
The maximum tensile force during installation is 100N and the minimum bend radius is 8x the outer diameter while pulling to preserve electrical characteristics.
What electrical measurements support link performance validation?
Key test values include DC loop resistance ≤154Ω/km, insulation resistance ≥5000MΩxkm at 500V, and nominal capacitance 48nF/km which inform link loss and continuity testing.
Related links
- Brand-Rex Cat6Plus Cat6 Ethernet Cable Purple, Unshielded Unscreened Low Smoke Zero Halogen Sheath
- HellermannTyton Connectivity CA Purple, Shielded Screened Low Smoke Fire Retardant Zero
- HellermannTyton Connectivity CA Purple, Shielded Screened Low Smoke Fire Retardant Zero
- HellermannTyton Connectivity CA076 Cat6 Cat6 Cable Violet, Unshielded Polyethylene Sheath
- StarTech.com Purple, Unshielded Unscreened Polyvinyl Chloride Sheath
- Belden 7965ENH Cat6 Ethernet Cable Blue, Unshielded Unscreened Low Smoke Zero Halogen Sheath
- StarTech.com N6PATC5MPL Purple, Unshielded Unscreened Polyvinyl Chloride Sheath
- StarTech.com N6PATC1MPL Purple, Unshielded Unscreened Polyvinyl Chloride Sheath