Aim-TTi TF960 Frequency Counter, 0.001 Hz Min, 6GHz Max, 10 Digit Resolution - With RS Calibration
- RS Stock No.:
- 766-3490
- Mfr. Part No.:
- TF960
- Brand:
- Aim-TTi
Price Each
Kr. 7 085,14
(exc. VAT)
Kr. 8 856,42
(inc. VAT)
4 In stock for delivery within 3-5 working days*
* Delivery dates may change based on your chosen quantity and delivery address.
Not available for next day delivery
Units | Per unit |
---|---|
1 + | Kr. 7 085,14 |
- RS Stock No.:
- 766-3490
- Mfr. Part No.:
- TF960
- Brand:
- Aim-TTi
RoHS Status: Exempted
- COO (Country of Origin):
- GB
Aim-TTi TF960 - 6GHz Universal Frequency Counter
The Aim-TTi TF960 is a 6GHz bench/portable universal counter with USB. It uses a high quality temperature-compensated internal frequency reference (TCXO) which has a low aging rate and is stable to within ±1ppm over the full temperature range. The instrument's short warm-up time enables accurate measurements to be made even under portable battery-powered conditions. An External Reference input is provided and changeover from the internal timebase is automatic when an external reference standard is connected. For frequency, period and frequency ratio functions, the TF960 uses a reciprocal counting technique to provide high resolution at all frequencies. Eight significant digits of answer are produced in a 1 second measurement time, nine digits in 10s and ten digits in 100s, with a granularity of less than 2 counts in the least significant digit.
Frequency, period, pulse width, frequency ratio, duty cycle and event counter modes
DC to 6000MHz range, 0.001mHz resolution
High impedance measurement up to 125 MHz
AC or DC coupling, 1M/50Ohm selection, polarity invert
Switchable attenuator, threshold control
Noise filter for low frequency measurements
Selectable measurement time; display hold function
Large 10 digit display with full range of annunciators
Internal rechargeable batteries for portable use
USB interface provides full remote control and readback
DC to 6000MHz range, 0.001mHz resolution
High impedance measurement up to 125 MHz
AC or DC coupling, 1M/50Ohm selection, polarity invert
Switchable attenuator, threshold control
Noise filter for low frequency measurements
Selectable measurement time; display hold function
Large 10 digit display with full range of annunciators
Internal rechargeable batteries for portable use
USB interface provides full remote control and readback
Aim-TTi Frequency Counter, 1 MΩ / 50 Ω Input Impedance, 260 x 235 x 88mm - TF960
This high-performance Aim-TTi frequency counter offers precision frequency measurement up to 6 GHz. With a Type-N connector and high-resolution capabilities, it is ideal for various applications in the automation, electronics, electrical, and mechanical industries. The counter provides accurate frequency measurements with 1:1 and 5:1 attenuation options.
Features & Benefits
• Includes a Type-N connector for versatile connectivity
• Offers high-resolution frequency measurements with 10-digit resolution
• Features 1:1 and 5:1 attenuation options for flexible signal conditioning
• Provides precise frequency measurements up to 6 GHz
• Equipped with a large 10-digit LCD display for easy readouts
• Offers high-resolution frequency measurements with 10-digit resolution
• Features 1:1 and 5:1 attenuation options for flexible signal conditioning
• Provides precise frequency measurements up to 6 GHz
• Equipped with a large 10-digit LCD display for easy readouts
Applications
• Frequency measurement in automation systems
• Signal analysis in electronic circuits
• Timebase reference in electrical equipment testing
• Duty cycle and event counting Applications
• Signal analysis in electronic circuits
• Timebase reference in electrical equipment testing
• Duty cycle and event counting Applications
Can it measure frequencies above 6 GHz?
This frequency counter is capable of measuring frequencies up to 6 GHz accurately.
Will it work with all types of frequency inputs?
Yes, the Type-N connector allows versatile input compatibility for a wide range of frequencies.
Is it suitable for portable use?
Yes, this frequency counter is designed for both bench-top and portable applications, offering flexibility in usage.
Can it measure pulse width and duty cycle?
Yes, this counter provides pulse width resolution and duty cycle measurements for comprehensive frequency analysis.
What is the measurement time for accurate readings?
The measurement time can be selected and adjusted to ensure precise and detailed frequency measurements.
Attribute | Value |
---|---|
Maximum Frequency | 6GHz |
Minimum Frequency | 0.001 Hz |
Resolution | 10 Digit |
Calibrated | RSCAL |
Pulse Width Resolution | 20ns |
Attenuation | 1:1, 5:1 |
Maximum Internal Counter | 9999999999 |
Minimum Internal Counter | 1 |
Maximum Input Voltage | 30V |
Input Impedance | 1 MΩ, 50 Ω |
Measurement Time | 100s |
Connector Type | Type-N |
Dimensions | 260 x 235 x 88mm |
Height | 88mm |
Minimum Operating Temperature | +5°C |
Width | 235mm |
Weight | 950g |
Model Number p | TF960 |
Length | 260mm |
Maximum Operating Temperature | +40°C |