Gossen Metrawatt M246C Insulation Tester, 10 V Min, 1 kV Max, 3.1 GΩ CAT III, CAT II
- RS Stock No.:
- 260-8276
- Distrelec Article No.:
- 303-02-389
- Mfr. Part No.:
- M246C
- Brand:
- Gossen Metrawatt
Subtotal (1 unit)*
Kr. 17 400,93
(exc. VAT)
Kr. 21 751,16
(inc. VAT)
FREE delivery for online orders over 750,00 kr
In Stock
- 3 unit(s) ready to ship from another location
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
|---|---|
| 1 + | Kr. 17 400,93 |
*price indicative
- RS Stock No.:
- 260-8276
- Distrelec Article No.:
- 303-02-389
- Mfr. Part No.:
- M246C
- Brand:
- Gossen Metrawatt
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Gossen Metrawatt | |
| Product Type | Insulation Tester | |
| Model Number | M246C | |
| Tester Type | Insulation Tester | |
| Minimum Test Voltage | 10V | |
| Maximum Test Voltage | 1kV | |
| Display Type | OLED | |
| Test Current | 1mA | |
| Battery Life | 200h | |
| Power Source | Battery | |
| Battery Type | AA | |
| Insulation Testing Resistance | 3.1GΩ | |
| Minimum Operating Temperature | -10°C | |
| Maximum Operating Temperature | 50°C | |
| Safety Category Voltage | 600V | |
| Safety Category Level | CAT III, CAT II | |
| Height | 87mm | |
| Length | 200mm | |
| Width | 45mm | |
| Standards/Approvals | VDE 04111:2002, VDE 0470, DIN EN 61010, EN 60529, DIN EN 613261, VDE 0843201 | |
| Weight | 350g | |
| Select all | ||
|---|---|---|
Brand Gossen Metrawatt | ||
Product Type Insulation Tester | ||
Model Number M246C | ||
Tester Type Insulation Tester | ||
Minimum Test Voltage 10V | ||
Maximum Test Voltage 1kV | ||
Display Type OLED | ||
Test Current 1mA | ||
Battery Life 200h | ||
Power Source Battery | ||
Battery Type AA | ||
Insulation Testing Resistance 3.1GΩ | ||
Minimum Operating Temperature -10°C | ||
Maximum Operating Temperature 50°C | ||
Safety Category Voltage 600V | ||
Safety Category Level CAT III, CAT II | ||
Height 87mm | ||
Length 200mm | ||
Width 45mm | ||
Standards/Approvals VDE 04111:2002, VDE 0470, DIN EN 61010, EN 60529, DIN EN 613261, VDE 0843201 | ||
Weight 350g | ||
- COO (Country of Origin):
- DE
Gossen-Metrawatt Insulation Tester, 1000V Maximum Test Voltage, 3.1 GΩ Insulation Resistance - M246C
This insulation tester is a handheld, battery-operated instrument designed to assess insulation resistance in electrical systems up to high voltage levels. It is intended for field and workshop use across a wide ambient temperature range and incorporates a clear LCD for result readout. The unit conforms to recognised industry standards and is supplied with formal calibration documentation to support measurement traceability.
Features and Benefits:
• *Made in Germany - including DAkkS calibration certificate and 3-year warranty (extendable to 5 years)
• 1 mA test current provides a measurable load for insulation diagnostics
• 1000 V maximum test voltage enables high-voltage insulation checks
• 3.1 GΩ insulation testing capability detects high-resistance faults
• AA battery power offers simple field battery replacement
• LCD display delivers clear numerical readouts for Rapid interpretation
• 1 mA test current provides a measurable load for insulation diagnostics
• 1000 V maximum test voltage enables high-voltage insulation checks
• 3.1 GΩ insulation testing capability detects high-resistance faults
• AA battery power offers simple field battery replacement
• LCD display delivers clear numerical readouts for Rapid interpretation
Applications
• Suitable for verifying insulation on motors and windings
• Used for maintenance of distribution equipment and switchgear
• Ideal for commissioning cable insulation in installations
• Can be used for routine condition monitoring of electrical assets
• Used with portable test setups in varied ambient conditions
• Used for maintenance of distribution equipment and switchgear
• Ideal for commissioning cable insulation in installations
• Can be used for routine condition monitoring of electrical assets
• Used with portable test setups in varied ambient conditions
What safety categories does the instrument support?
It is rated for CAT III and CAT II applications, enabling use on distribution-level and lower-energy circuits.
How long will the unit operate between battery changes?
The AA battery supply provides approximately 200 h of operational life under typical test conditions.
What environmental temperatures can it tolerate during operation?
It operates across a range from -10 °C up to 50 °C, suitable for most indoor and sheltered outdoor tasks.
Does the instrument include formal calibration evidence?
A DAkkS calibration certificate is provided to confirm measurement traceability and accuracy.
How heavy and portable is the tester for field work?
The instrument weighs 350 g, making it lightweight for handheld portable testing.
Related links
- Gossen Metrawatt M246C Insulation Tester 1000 V Max CAT II, RSCAL
- Gossen Metrawatt M246C Insulation Tester 1000 V Max CAT II, UKAS
- Gossen Metrawatt METRISO TECH Insulation Tester 1000 V Max CAT IV, CAT III
- Gossen Metrawatt METRISO 1000A Insulation Tester 1000 V Max, 400 MΩ CAT II
- Chauvin Arnoux CA 6503 Insulation Tester 1000 V Max CAT II
- Gossen Metrawatt M550S Insulation Tester 1000 V Max, 999 GΩ Flat Countersunk
- Gossen Metrawatt METRISO PRIME Insulation Tester 5000 V Max CAT III, CAT II
- Megger MIT420 2 Insulation Tester 1000 V Max UKAS