Siemens 3-Pole Floor Switch Disconnector -, IP65, 16A, 8 kW
- RS Stock No.:
- 239-2617
- Mfr. Part No.:
- 3LD2017-0TK13
- Brand:
- Siemens
Subtotal (1 unit)*
Kr. 993,68
(exc. VAT)
Kr. 1 242,10
(inc. VAT)
FREE delivery for online orders over 750,00 kr
Temporarily out of stock
- 6 unit(s) shipping from 09 November 2026
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
|---|---|
| 1 + | Kr. 993,68 |
*price indicative
- RS Stock No.:
- 239-2617
- Mfr. Part No.:
- 3LD2017-0TK13
- Brand:
- Siemens
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Siemens | |
| Number of Poles | 3 | |
| Product Type | Switch Disconnector | |
| Mount Type | Floor | |
| IP Rating | IP65 | |
| Handle Colour | Red, Yellow | |
| Auxiliary Contacts Available | Yes | |
| Switching Current | 16A | |
| Series | 3LD | |
| Terminal Type | Box | |
| Padlock Compatibility | Yes | |
| Switching Power | 8kW | |
| Minimum Operating Temperature | -25°C | |
| Switching AC Voltage | 600V ac | |
| Maximum Operating Temperature | 55°C | |
| Hazardous Area Certification | No | |
| Depth | 385mm | |
| Length | 75mm | |
| Standards/Approvals | UL 60947-4-1, UL 508 | |
| Width | 67mm | |
| Select all | ||
|---|---|---|
Brand Siemens | ||
Number of Poles 3 | ||
Product Type Switch Disconnector | ||
Mount Type Floor | ||
IP Rating IP65 | ||
Handle Colour Red, Yellow | ||
Auxiliary Contacts Available Yes | ||
Switching Current 16A | ||
Series 3LD | ||
Terminal Type Box | ||
Padlock Compatibility Yes | ||
Switching Power 8kW | ||
Minimum Operating Temperature -25°C | ||
Switching AC Voltage 600V ac | ||
Maximum Operating Temperature 55°C | ||
Hazardous Area Certification No | ||
Depth 385mm | ||
Length 75mm | ||
Standards/Approvals UL 60947-4-1, UL 508 | ||
Width 67mm | ||
- COO (Country of Origin):
- DE
Siemens 3LD Series Switch Disconnector, 16A Rated Current, 600V ac Operating Voltage - 3LD2017-0TK13
This switch disconnector provides a manual emergency-off isolator for three-pole circuits in industrial installations. It is intended for floor mounting with door coupling and a defeatable knob-operated mechanism featuring a red/yellow handle. The device supports main-switch use and maintenance isolation while offering IP65 front protection for use in varied indoor and sheltered outdoor settings.
Features and Benefits:
• 16A rated current for sustained circuit switching
• 8kW switching power at AC-23 for motor and load control
• IP65 front protection for ingress resistance
• Padlock compatible to secure the OFF position
• Operating range -25°C to 55°C for broad ambient use
• 8kW switching power at AC-23 for motor and load control
• IP65 front protection for ingress resistance
• Padlock compatible to secure the OFF position
• Operating range -25°C to 55°C for broad ambient use
Applications
• Suitable for machinery emergency-off isolation on factory floors
• Ideal for integration with control panels having door coupling
• Used with motor loads requiring AC-23 switching capability
• Can be used where padlockable safety isolation is required
• Suitable for installations demanding IP65-rated controls
• Ideal for integration with control panels having door coupling
• Used with motor loads requiring AC-23 switching capability
• Can be used where padlockable safety isolation is required
• Suitable for installations demanding IP65-rated controls
What types of connections does it accept?
The main circuit uses box terminals for copper conductors up to 6mm² solid or stranded, with auxiliary connection terminals for auxiliary switches.
How is short-circuit protection managed?
The main circuit requires a gL/gG fuse and is specified with upstream fuse ratings and let-through current limits for coordinated protection.
What auxiliary contact options are available?
Up to three NC and five NO attachable auxiliary contacts can be fitted, with the auxiliary switch rated for 10A continuous current.
What approvals cover electrical and safety ratings?
It meets UL 60947-4-1 and UL 508 requirements for operational current and voltage at 50/60Hz, including specified SCCR values at 600V.
How is the device mounted and secured mechanically?
It is a fixed-mounting device with four-hole front mounting and supports rail mounting
the handle uses a four-hole mounting configuration for fastening.
Related links
- Siemens 4-Pole Panel Mount Non-Fused Switch Disconnector - 16A, 7.5 kW
- Siemens 3-Pole Panel Mount Non-Fused Isolator Switch - 16A, 8 kW
- Siemens 3-Pole Panel Mount Non-Fused Switch Disconnector - 63A, 22 kW
- Siemens 3-Pole Panel Mount Isolator Switch - 16A, 8 kW
- Siemens 3-Pole Panel Mount Non-Fused Switch Disconnector - 16A, 7.5 kW
- Siemens 3-Pole Panel Mount Non-Fused Switch Disconnector - 25A, 9.5 kW
- Siemens 3-Pole Panel Mount Non-Fused Switch Disconnector - 32A, 11.5 kW
- Siemens 3-Pole Panel Mount Non-Fused Switch Disconnector - 125A, 45 kW
