Honeywell GLC Series Roller Lever Limit Switch, SPDT, IP66, Die Cast Zinc Housing, 240V ac, 10A
- RS Stock No.:
- 808-3139
- Mfr. Part No.:
- GLCA01A2A
- Brand:
- Honeywell
Bulk discount available
Subtotal (1 unit)*
Kr. 1 332,20
(exc. VAT)
Kr. 1 665,25
(inc. VAT)
FREE delivery for online orders over 750,00 kr
In Stock
- 12 unit(s) ready to ship
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
|---|---|
| 1 - 4 | Kr. 1 332,20 |
| 5 - 9 | Kr. 1 294,79 |
| 10 + | Kr. 1 260,13 |
*price indicative
- RS Stock No.:
- 808-3139
- Mfr. Part No.:
- GLCA01A2A
- Brand:
- Honeywell
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Honeywell | |
| Product Type | Limit Switch | |
| Actuator Type | Roller Lever | |
| Contact Configuration | SPDT | |
| IP Rating | IP66 | |
| Housing Material | Die Cast Zinc | |
| Contact Type | Snap Action | |
| Switching Current | 10A | |
| Terminal Type | Screw | |
| Series | GLC | |
| Switching DC Voltage | 250V dc | |
| Switching AC Voltage | 240V ac | |
| Minimum Operating Temperature | -40°C | |
| Maximum Operating Temperature | 85°C | |
| Depth | 55mm | |
| Standards/Approvals | UL, RoHS, IEC, EN, CSA, CE, CCC | |
| Width | 30mm | |
| Length | 30.5mm | |
| Hazardous Area Certification | NO | |
| Operating Force | 0.12Nm | |
| Mounting Orientation | Side | |
| Mechanical Life | 15000000Operations | |
| Conduit Entry | 1/2 in to 14 NPT | |
| Select all | ||
|---|---|---|
Brand Honeywell | ||
Product Type Limit Switch | ||
Actuator Type Roller Lever | ||
Contact Configuration SPDT | ||
IP Rating IP66 | ||
Housing Material Die Cast Zinc | ||
Contact Type Snap Action | ||
Switching Current 10A | ||
Terminal Type Screw | ||
Series GLC | ||
Switching DC Voltage 250V dc | ||
Switching AC Voltage 240V ac | ||
Minimum Operating Temperature -40°C | ||
Maximum Operating Temperature 85°C | ||
Depth 55mm | ||
Standards/Approvals UL, RoHS, IEC, EN, CSA, CE, CCC | ||
Width 30mm | ||
Length 30.5mm | ||
Hazardous Area Certification NO | ||
Operating Force 0.12Nm | ||
Mounting Orientation Side | ||
Mechanical Life 15000000Operations | ||
Conduit Entry 1/2 in to 14 NPT | ||
Honeywell GLC Series Limit Switch, Roller Lever Actuator, IP66 - GLCA01A2A
This limit switch provides a compact, mechanical sensing solution for industrial control systems, detecting position changes via a roller lever actuator. It is designed for side mounting and delivers snap-action switching suitable for automation, electrical and mechanical installations where environmental protection and reliable actuation are required.
Features and Benefits:
• Die-cast zinc housing offers robust protection in harsh environments
• SPDT snap-action contact enables clear make–break switching at rated loads
• Rated switching 10A at 240V AC for common control circuits
• Switching capability to 250V DC supports DC control applications
• IP66 ingress rating ensures resistance to dust and powerful water jets
• Mechanical endurance of 15 million operations reduces maintenance intervals
• SPDT snap-action contact enables clear make–break switching at rated loads
• Rated switching 10A at 240V AC for common control circuits
• Switching capability to 250V DC supports DC control applications
• IP66 ingress rating ensures resistance to dust and powerful water jets
• Mechanical endurance of 15 million operations reduces maintenance intervals
Applications
• Suitable for conveyor end-of-travel detection in manufacturing lines
• Ideal for interlock sensing on machinery guards and access panels
• Used with pneumatic actuators to confirm cylinder stroke completion
• Can be used for limit detection in material handling equipment
• Ideal for interlock sensing on machinery guards and access panels
• Used with pneumatic actuators to confirm cylinder stroke completion
• Can be used for limit detection in material handling equipment
What conduit entry option does it accommodate for cable connection?
The unit accepts a 1/2 in to 14 NPT conduit entry, allowing standard threaded conduit fittings.
What temperature range can it operate within reliably?
It functions between −25°C and 85°C, supporting both cold storage and warm plant-room environments.
Which approvals cover its use in regulated installations?
It carries approvals from UL, RoHS, IEC, EN, CSA, CE and CCC, permitting deployment across multiple compliance regimes.
How is the switch intended to be mounted on equipment?
The design is for side-orientation mounting to suit applications where lateral actuation is required.
Approvals
UL/ UL listed for Canada
Warning
GLC and GLD limit switches are not safety devices. They should be not used as emergency stop or safety devices. They must not be used in applications where personal injury could occur as a result of product failure.
Standards
IEC/EN 60947-5-1
While IEC/EN 609747-1 covers general rules relating to low voltage switchgear and controlgear, IEC/EN 60947-5-1 specifically relates to control circuit devices and switching elements. The standard monitors the characteristics of devices, the electrical and mechanical requirements and the functional requirements.
EN50047
GLC and GLD limit switches are constructed from housing that meets EN50047. EN50047 applies to position switches with an automatic return actuator. Models that meet EN50047 feature standardised characteristics and dimensions (30.5 x 31.1 x 68 mm).
IP 66
A rating of IP 66 ensures that the limit switch units are protected against dust and low-pressure jets of water.
Sealed to NEMA 1, 4, 12, 13
NEMA 1 states that enclosures can be used indoor and offers a degree of protection against contact with the equipment enclosed.
NEMA 4 states that enclosures can be used either indoor or outdoor and provide protection against windblown rain and dust, hose directed water and splashing water.
NEMA 12 states that enclosures are intended for use indoors and offer some protection from dust, dirt, falling dirt and dripping non-corrosive liquids.
NEMA 13 states that enclosures are used indoors and offer a level of protection from oil, non-corrosive coolants, spraying water and dust.
While IEC/EN 609747-1 covers general rules relating to low voltage switchgear and controlgear, IEC/EN 60947-5-1 specifically relates to control circuit devices and switching elements. The standard monitors the characteristics of devices, the electrical and mechanical requirements and the functional requirements.
EN50047
GLC and GLD limit switches are constructed from housing that meets EN50047. EN50047 applies to position switches with an automatic return actuator. Models that meet EN50047 feature standardised characteristics and dimensions (30.5 x 31.1 x 68 mm).
IP 66
A rating of IP 66 ensures that the limit switch units are protected against dust and low-pressure jets of water.
Sealed to NEMA 1, 4, 12, 13
NEMA 1 states that enclosures can be used indoor and offers a degree of protection against contact with the equipment enclosed.
NEMA 4 states that enclosures can be used either indoor or outdoor and provide protection against windblown rain and dust, hose directed water and splashing water.
NEMA 12 states that enclosures are intended for use indoors and offer some protection from dust, dirt, falling dirt and dripping non-corrosive liquids.
NEMA 13 states that enclosures are used indoors and offer a level of protection from oil, non-corrosive coolants, spraying water and dust.
Related links
- Honeywell GLC Series Roller Lever Limit Switch IP66 240 V ac, 6 A
- Honeywell GLC Series Roller Lever Limit Switch IP66 240 V ac, 10 A
- Honeywell GLC Series Adjustable Roller Lever Limit Switch IP66 240 V ac, 10 A
- Honeywell GLC Series Adjustable Roller Lever Limit Switch IP66 240 V ac, 6 A
- Honeywell GLC Series Rotary Lever Limit Switch IP66 240 V ac, 6 A
- Honeywell GLC Series Roller Plunger Limit Switch IP66 240 V ac, 6 A
- Honeywell GLC Series Roller Plunger Limit Switch IP66 240 V ac, 10 A
- Honeywell GLC Series Plunger Limit Switch IP66 240 V ac, 6 A