Schneider Electric Multi9 Multi9 Miniature Circuit Breaker, 1-Pole, 4A, Type C, 60 V dc DC, 10 kA Breaking Capacity
- RS Stock No.:
- 219-9115
- Mfr. Part No.:
- M9F22104
- Brand:
- Schneider Electric
Subtotal (1 unit)*
Kr. 259,34
(exc. VAT)
Kr. 324,18
(inc. VAT)
FREE delivery for online orders over 750,00 kr
In Stock
- Plus 33 unit(s) shipping from 13 April 2026
- Plus 35 unit(s) shipping from 13 April 2026
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
|---|---|
| 1 + | Kr. 259,34 |
*price indicative
- RS Stock No.:
- 219-9115
- Mfr. Part No.:
- M9F22104
- Brand:
- Schneider Electric
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Schneider Electric | |
| Product Type | Miniature Circuit Breaker | |
| Number of Poles | 1 | |
| Current Rating | 4A | |
| Tripping Characteristics | Type C | |
| Rated DC Voltage | 60V dc | |
| Mount Type | Clip-on | |
| Breaking Capacity | 10kA | |
| Range | Multi9 | |
| Series | Multi9 | |
| Terminal Type | Tunnel | |
| Width | 18mm | |
| Height | 81mm | |
| Depth | 72mm | |
| Standards/Approvals | CSA C22.2 No 235, EN/IEC 60947-2, GB 14048.2, UL 1077 | |
| Tripping Mechanism | Thermal Magnetic | |
| Select all | ||
|---|---|---|
Brand Schneider Electric | ||
Product Type Miniature Circuit Breaker | ||
Number of Poles 1 | ||
Current Rating 4A | ||
Tripping Characteristics Type C | ||
Rated DC Voltage 60V dc | ||
Mount Type Clip-on | ||
Breaking Capacity 10kA | ||
Range Multi9 | ||
Series Multi9 | ||
Terminal Type Tunnel | ||
Width 18mm | ||
Height 81mm | ||
Depth 72mm | ||
Standards/Approvals CSA C22.2 No 235, EN/IEC 60947-2, GB 14048.2, UL 1077 | ||
Tripping Mechanism Thermal Magnetic | ||
- COO (Country of Origin):
- FR
Schneider Electric C60SP Series MCB, 4A Current Rating , 10 kA Breaking Capacity - M9F22104
This MCB is an essential electrical safety device designed for dependable circuit protection in various applications. With a current rating of 4A and a single pole configuration, it fits seamlessly onto a DIN rail, facilitating easy installation in electrical cabinets. The Compact dimensions of 81mm in length, 18mm in width, and 72mm in depth enhance its versatility for multiple setups. This device boasts a thermal-magnetic tripping mechanism, ensuring responsiveness to both overload and short-circuit conditions.
Features & Benefits
• 10 kA breaking capacity provides robust protection against high fault currents
• Type C tripping characteristics are Ideal for inductive loads
• Compact design maximises space efficiency in electrical systems
• Contributes to a sustainable environment as a Better World Product
• Type C tripping characteristics are Ideal for inductive loads
• Compact design maximises space efficiency in electrical systems
• Contributes to a sustainable environment as a Better World Product
Applications
• Ideal for residential and commercial electrical distribution systems
• Used for protecting lighting circuits and small motors
• Suitable for requiring reliable overcurrent protection
• Utilised in automation control panels and electrical cabinets
• Appropriate for installation in industrial machinery and equipment
• Used for protecting lighting circuits and small motors
• Suitable for requiring reliable overcurrent protection
• Utilised in automation control panels and electrical cabinets
• Appropriate for installation in industrial machinery and equipment
What types of loads are suitable for use with this circuit breaker?
This circuit breaker is best suited for inductive loads such as motors and transformers, as it is specifically designed with Type C tripping characteristics to manage inrush currents effectively.
How does the thermal-magnetic mechanism work to prevent electrical faults?
The thermal-magnetic mechanism operates by detecting excessive currents: the thermal element reacts to prolonged overloads, while the magnetic component responds quickly to short circuits, ensuring swift disconnection from the power supply.
What installation requirements should be considered for this device?
When installing, ensure that it is mounted on a standard DIN rail and that the electrical panel meets necessary specifications for protection and accessibility.
Can it be used in combination with other circuit protection devices?
Yes, this MCB can be used alongside other protective devices such as RCDs or additional MCBs to provide comprehensive electrical safety and enhanced performance in various circuits.
Related links
- Schneider Electric Multi9 Multi9 Miniature Circuit Breaker 4A 60 V dc DC, 10 kA Breaking Capacity
- Schneider Electric Multi9 Multi9 Miniature Circuit Breaker 4A 60 V dc DC, 10 kA Breaking Capacity
- Schneider Electric Multi9 Multi9 Miniature Circuit Breaker 4A 60 V dc DC, 20 kA Breaking Capacity
- Schneider Electric Multi9 Multi9 Miniature Circuit Breaker 4A 60 V dc DC, 20 kA Breaking Capacity
- Schneider Electric Multi9 Multi9 Miniature Circuit Breaker 4A 125 V dc DC, 10 kA Breaking Capacity
- Schneider Electric Multi9 Multi9 Miniature Circuit Breaker 4A 125 V dc DC, 10 kA Breaking Capacity
- Schneider Electric Multi9 Multi9 Miniature Circuit Breaker 4A 10 kA Breaking Capacity
- Schneider Electric Multi9 Multi9 Miniature Circuit Breaker 500mA 60 V dc DC, 10 kA Breaking Capacity