Fluke calibration 8808A/TL 240V 8808A Bench Digital Multimeter True RMS, 10 A ac, 10 A dc, 750 V ac, UKAS Calibrated
- RS Stock No.:
- 260-2798
- Mfr. Part No.:
- 8808A/TL 240V
- Brand:
- Fluke calibration
Subtotal (1 unit)*
Kr. 14 795,00
(exc. VAT)
Kr. 18 493,75
(inc. VAT)
FREE delivery for online orders over 750,00 kr
- 2 unit(s) shipping from 08 October 2026
Units | Per unit |
|---|---|
| 1 + | Kr. 14 795,00 |
*price indicative
- RS Stock No.:
- 260-2798
- Mfr. Part No.:
- 8808A/TL 240V
- Brand:
- Fluke calibration
Select all | Attribute | Value |
|---|---|---|
| Brand | Fluke calibration | |
| Product Type | Digital Multimeter | |
| Multimeter Type | Bench | |
| Display Type | Digital | |
| Resistance Resolution | 1mΩ | |
| Model Number | 8808A/TL 240V | |
| Functions Measured | AC Current, AC Voltage, Capacitance, Continuity, DC Current, DC Voltage, Frequency, Resistance, Temperature | |
| Maximum AC Voltage Measurement | 750V ac | |
| Maximum AC Current Measurement | 10A ac | |
| Maximum DC Current Measurement | 10A dc | |
| Maximum DC Voltage Measurement | 1kV dc | |
| Maximum Resistance Measurement | 0.1GΩ | |
| True RMS | Yes | |
| AC Voltage Accuracy | ±0.2 % rdg | |
| AC Current Accuracy | ±0.3 % rdg | |
| DC Current Accuracy | 0.02 % rdg | |
| DC Voltage Accuracy | ±0.015 % rdg + 0.003 | |
| DC Voltage Resolution | 1 μV | |
| AC Current Resolution | 100μA ac | |
| AC Voltage Resolution | 1μV | |
| DC Current Resolution | 1nA ac | |
| Maximum Frequency | 1MHz | |
| Minimum Operating Temperature | 0°C | |
| Resistance Measurement Accuracy | 0.02 % rdg + 0.003 % range | |
| Height | 88mm | |
| Series | 8808A | |
| Width | 217mm | |
| Standards/Approvals | ANSI/ISA 61010-1 (S82.02.01):2004, AN/CSA C22.2, EN 61010-1:2001, UL 61010-1:2004 | |
| Weight | 2.1kg | |
| Length | 297mm | |
| Safety Category Level | Connector Bracket, Joint | |
| Safety Category Voltage | 1000V dc | |
| Calibrated | UKAS | |
| Select all | ||
|---|---|---|
Brand Fluke calibration | ||
Product Type Digital Multimeter | ||
Multimeter Type Bench | ||
Display Type Digital | ||
Resistance Resolution 1mΩ | ||
Model Number 8808A/TL 240V | ||
Functions Measured AC Current, AC Voltage, Capacitance, Continuity, DC Current, DC Voltage, Frequency, Resistance, Temperature | ||
Maximum AC Voltage Measurement 750V ac | ||
Maximum AC Current Measurement 10A ac | ||
Maximum DC Current Measurement 10A dc | ||
Maximum DC Voltage Measurement 1kV dc | ||
Maximum Resistance Measurement 0.1GΩ | ||
True RMS Yes | ||
AC Voltage Accuracy ±0.2 % rdg | ||
AC Current Accuracy ±0.3 % rdg | ||
DC Current Accuracy 0.02 % rdg | ||
DC Voltage Accuracy ±0.015 % rdg + 0.003 | ||
DC Voltage Resolution 1 μV | ||
AC Current Resolution 100μA ac | ||
AC Voltage Resolution 1μV | ||
DC Current Resolution 1nA ac | ||
Maximum Frequency 1MHz | ||
Minimum Operating Temperature 0°C | ||
Resistance Measurement Accuracy 0.02 % rdg + 0.003 % range | ||
Height 88mm | ||
Series 8808A | ||
Width 217mm | ||
Standards/Approvals ANSI/ISA 61010-1 (S82.02.01):2004, AN/CSA C22.2, EN 61010-1:2001, UL 61010-1:2004 | ||
Weight 2.1kg | ||
Length 297mm | ||
Safety Category Level Connector Bracket, Joint | ||
Safety Category Voltage 1000V dc | ||
Calibrated UKAS | ||
- COO (Country of Origin):
- CN
Fluke Digital Multimeter, 1kV Maximum DC Voltage, 10A Maximum DC Current - 8808A/TL 240V
Features and Benefits:
• 1μV DC voltage resolution for minute signal detection
• True RMS AC measurements for accurate non-sinusoidal waveform readings
• 10A AC/DC current capability for high-current testing
• 1MHz frequency limit for high-speed signal evaluation
• 0.1GΩ resistance range for large insulation and resistance checks
Applications
• Ideal for power-supply verification and calibration tasks
• Used for frequency response measurement in electronic development
• Can be used for capacitance and temperature characterisation in labs
• Used with maintenance routines requiring continuity and resistance checks
What input protection or safety classification does it offer?
What approvals confirm its adherence to international safety norms?
What measurement stability can I expect for resistance readings?
How Compact and portable is the instrument for bench use?
Related links
- Fluke calibration 8808A/TL 240V 8808A Bench Multimeter True RMS 10 A dc RSCAL Calibrated
- Fluke calibration 8808A/TL 240V 8808A Bench Multimeter True RMS 10 A dc, 750 V ac
- Fluke calibration 8808A Bench Multimeter True RMS 10 A dc UKAS Calibrated
- Fluke calibration 8808A/SU 8808A Bench Multimeter True RMS 10 A dc UKAS Calibrated
- Fluke calibration 8808A/SU 8808A Bench Multimeter True RMS 10 A dc, 750 V ac
- Fluke calibration 8808A Bench Multimeter True RMS 10 A dc RSCAL Calibrated
- Fluke calibration 8808A/SU 8808A Bench Multimeter True RMS 10 A dc RSCAL Calibrated
- Fluke calibration 8808A Bench Multimeter True RMS 10 A dc, 750 V ac