Lapp 4 Core, Black Rubber Sheath Power Cable +60°C
- RS Stock No.:
- 817-9038
- Mfr. Part No.:
- 16001063
- Brand:
- Lapp
Bulk discount available
Price 1 Reel of 100 Metre(s)**
Kr. 9 721,25
(exc. VAT)
Kr. 12 151,56
(inc. VAT)
9 In stock for same day dispatch*
* Delivery dates may change based on your chosen quantity and delivery address.
FREE delivery for orders over kr 500,00
Reel(s) | Per Reel | Per Metre** |
---|---|---|
1 - 4 | Kr. 9 721,25 | Kr. 97,212 |
5 - 9 | Kr. 9 128,20 | Kr. 91,282 |
10 + | Kr. 8 603,36 | Kr. 86,034 |
**price indicative
- RS Stock No.:
- 817-9038
- Mfr. Part No.:
- 16001063
- Brand:
- Lapp
- COO (Country of Origin):
- DE
H07RN-F Heavy Duty High Stress Rubber Cable
From Lapp, the H07RN-F cable is ideal for handheld and power supply devices. This heavy duty rubber sheathed cable is designed to withstand medium mechanical stress, and is often found used in challenging environments. Thanks to the cable's resistance to cold, water and UV, it can even be used for some outdoor applications.
Comprised of a harmonized fine wire copper strand with a rubber compound core insulation and outer sheath, this single-core black rubber cable is halogen free and flame resistant. Flexible and reliable, the Lapp H07RN-F cable is often used as a safe and reliable way to connect machinery and equipment to mains power.
Features and Benefits
according to EN 50525-2-21
High stresses
For protected and fixed installation permitted up to 1000V
Flame Retardant to IEC 60332-1-2
Oil-resistant according to EN 60811-404
Normativity not ozone resistant
Applications
This H07RN-F can be used for circuit proof and short to ground proof installations. The cable is environmentally resistant, and is tough enough to use in demanding application such as;
Water Treatment
Refrigerated Environments
Construction Work-sites
Stage and Studio Cabling
Agricultural and Industrial
What Does H07RN-F Mean?
H07RN-F cable is a type of harmonised cable which means it belongs to the Harmonised Reference System and conforms to the European Harmonisation Standard. This purpose of this standard is to improve standards and quality of cables across Europe to ensure the trade of common standard product.
H07RN-F is the code for this harmonised cable which breaks down into the following:
H = Harmonised
07 = 450 / 750 voltage rating
R = Natural or synthetic rubber insulation
N = Chloroprene or polychloroprene rubber sheath
F = Flexible copper conductors
Comprised of a harmonized fine wire copper strand with a rubber compound core insulation and outer sheath, this single-core black rubber cable is halogen free and flame resistant. Flexible and reliable, the Lapp H07RN-F cable is often used as a safe and reliable way to connect machinery and equipment to mains power.
Features and Benefits
High stresses
For protected and fixed installation permitted up to 1000V
Flame Retardant to IEC 60332-1-2
Oil-resistant according to EN 60811-404
Normativity not ozone resistant
Applications
This H07RN-F can be used for circuit proof and short to ground proof installations. The cable is environmentally resistant, and is tough enough to use in demanding application such as;
Water Treatment
Refrigerated Environments
Construction Work-sites
Stage and Studio Cabling
Agricultural and Industrial
What Does H07RN-F Mean?
H07RN-F cable is a type of harmonised cable which means it belongs to the Harmonised Reference System and conforms to the European Harmonisation Standard. This purpose of this standard is to improve standards and quality of cables across Europe to ensure the trade of common standard product.
H07RN-F is the code for this harmonised cable which breaks down into the following:
H = Harmonised
07 = 450 / 750 voltage rating
R = Natural or synthetic rubber insulation
N = Chloroprene or polychloroprene rubber sheath
F = Flexible copper conductors
Standards
IEC 60332-1-2, EN 60811-2-1, HD 22.4/VDE 0282-4 and HD 22.1/VDE 0282-1, HAR, RoHS, CE
LAPP 4-Core Power Cable, 100m Length, 11AWG - 16001063
Looking for a safe and reliable way to connect your industrial, domestic and commercial machinery and equipment to a mains power supply? This core power cable from LAPP delivers uninterrupted and dependable electricity from power sources to your applications. A heavy-duty rubber sheath withstands medium mechanical stress, assuring you of the product's quality and making it hard-wearing so you can confidently use it in demanding environments. Resistance to cold, water and UV damage makes this a good choice for outdoor electrical installations.
Features & Benefits
• Quality and safety-tested to handle alternating voltage of up 1,000V for protected and fixed installations
• Flame-retardant construction for peace of mind in the event of a fire
• Wide operating temperature range from -25°C to +60°C for use in harsh conditions
• Oil resistance for a long-lasting product that effectively protects internal conductors
• Flame-retardant construction for peace of mind in the event of a fire
• Wide operating temperature range from -25°C to +60°C for use in harsh conditions
• Oil resistance for a long-lasting product that effectively protects internal conductors
Applications
• Industrial machinery
• Automated agricultural equipment
• Light and sound technologies
• Automated agricultural equipment
• Light and sound technologies
What Does H07RN-F Mean?
This term refers to a type of harmonised cable and the associated referencing system. The 'H' stands for harmonised, while the '07' indicates a 450/470 voltage rating. The 'R' refers to the cable's natural or synthetic rubber insulation and the 'N' a chloroprene or polychloroprene rubber sheath. Lastly, the 'F' stands for flexible copper conductors.
Attribute | Value |
---|---|
Cross Sectional Area | 4 mm² |
Number of Cores | 4 |
Sheath Colour | Black |
Length | 100m |
Current Rating | 34 A |
Outer Diameter | 14 → 17.9mm |
Sheath Material | Rubber |
CPR Certification | Eca |
Voltage Rating | 450/750 V |
European Harmonised Code | H07RN-F |
Conductor Strand Type | Stranded |
Number of Strands | 56 |
Conductor Material | Copper |
Maximum Operating Temperature | +60°C |
Standards Met | CE |
Core Strands | 56/0.3 mm |
American Wire Gauge | 11 AWG |
Fire Behaviour | Flame Retardant |
Size of Strands | 0.3 mm |
Insulation Material | Rubber |
Conductor Resistance | 4.95 Ω/km |
Minimum Operating Temperature | -25°C |