Honeywell Technologies SSCDRRN001PDAA5 Piezoresistive Pressure SensorThrough Hole 8 DIP

Bulk discount available
View bulk pricing options

Subtotal (1 unit)*

Kr. 490,32

(exc. VAT)

Kr. 612,90

(inc. VAT)

Add to Basket
Select or type quantity
Stock information currently inaccessible - Please check back later

Units
Per unit
1 - 9Kr. 490,32
10 - 24Kr. 477,62
25 - 49Kr. 465,26
50 +Kr. 453,60

*price indicative

Packaging Options:
RS Stock No.:
226-9744
Mfr. Part No.:
SSCDRRN001PDAA5
Brand:
Honeywell
Find similar products by selecting one or more attributes.
Select all

Brand

Honeywell

Maximum Overload Pressure

1kPa

Sensor Type

Piezoresistive Pressure Sensor

Product Type

Piezoresistive Pressure Sensor

Mount Type

Through Hole

Package Type

DIP

Pin Count

8

Minimum Supply Voltage

3.3V

Maximum Operating Pressure

0.1 kPa

Accuracy

±0.25 %

Port Type

Dual Radial Barbed

Maximum Supply Voltage

5V

Maximum Operating Temperature

85°C

Height

13.75mm

Standards/Approvals

No

Series

SSC

Length

10mm

Minimum Operating Pressure

1psi

Automotive Standard

No

Minimum Operating Temperature

-40°C

Honeywell SSC Series Piezoresistive Pressure Sensor, 3.3V Minimum Supply Voltage, ±0.25% accuracy - SSCDRRN001PDAA5


This piezoresistive pressure sensor converts low-pressure differentials into readable electrical signals for precision measurement in controlled environments. It operates from a low-voltage supply and is intended for through-hole PCB mounting where a compact, barbed-port transducer is required. The device is suitable for systems needing fine-resolution readings across a defined temperature range.

Features and Benefits:


• 3.3 to 5V supply range enables low-voltage system integration
• ±0.25% accuracy delivers precise measurement repeatability
• 1 psi minimum sensitivity supports very low-pressure detection
• 0.1kPa maximum range allows ultralow-pressure monitoring
• 1kPa overload capability protects against pressure spikes

Applications


• Suitable for laboratory gas-flow measurement setups
• Ideal for medical-device low-pressure monitoring
• Used for environmental pressure sampling systems
• Can be used for pneumatic leak-detection circuits
• Suitable for industrial low-pressure instrumentation

What packaging and mounting style does it use?


It is supplied in a DIP package with through-hole mounting for soldered PCB installation.

How is the sensor connected to the measured medium?


Dual radial barbed ports provide secure tubing connections for liquid or gas input.

What are the electrical pin and voltage constraints?


The device presents eight pins and must be operated between 3.3V and 5V supply levels.

What operational temperature limits apply?


The sensor operates from -40°C to 85°C.

What physical footprint should be allowed for PCB layout?


Allow a Compact area of approximately 13.5mm by 13.75mm for the component.