Schneider Electric Residual Current Circuit Breaker with Overload Protection, 10A Current Rating, 1-Pole, 30 mA Trip
- RS Stock No.:
- 654-680
- Mfr. Part No.:
- A9D56610
- Brand:
- Schneider Electric
Subtotal (1 unit)*
Kr. 1 612,93
(exc. VAT)
Kr. 2 016,16
(inc. VAT)
Stock information currently inaccessible - Please check back later
Units | Per unit |
|---|---|
| 1 + | Kr. 1 612,93 |
*price indicative
- RS Stock No.:
- 654-680
- Mfr. Part No.:
- A9D56610
- Brand:
- Schneider Electric
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Schneider Electric | |
| Current Rating | 10A | |
| Product Type | Residual Current Circuit Breaker with Overload Protection | |
| Number of Poles | 1 | |
| Range | Acti9 | |
| Series | A9d | |
| Trip Sensitivity | 30mA | |
| Tripping Characteristics | Type B | |
| Terminal Type | Screw Clamp | |
| Depth | 72mm | |
| Height | 110mm | |
| Width | 18mm | |
| Breaking Capacity | 10000A | |
| Application | Distribution | |
| Standards/Approvals | BS EN 61009-1, IEC 61009-1, IEC 61009-2-2 | |
| Select all | ||
|---|---|---|
Brand Schneider Electric | ||
Current Rating 10A | ||
Product Type Residual Current Circuit Breaker with Overload Protection | ||
Number of Poles 1 | ||
Range Acti9 | ||
Series A9d | ||
Trip Sensitivity 30mA | ||
Tripping Characteristics Type B | ||
Terminal Type Screw Clamp | ||
Depth 72mm | ||
Height 110mm | ||
Width 18mm | ||
Breaking Capacity 10000A | ||
Application Distribution | ||
Standards/Approvals BS EN 61009-1, IEC 61009-1, IEC 61009-2-2 | ||
- COO (Country of Origin):
- ES
The Schneider Electric Residual current circuit breaker with overcurrent protection (RCD/MCB) Acti 9 iDPN N Vigi, 6kA (IEC/EN 61009-2-1). 1-pole plus N, rated current 10A, characteristic B, earth fault sensitivity 30mA, earth fault protection class Type A, operating voltage (Ue) 230V AC, insulation voltage (Ui) 400V AC. Ensures comprehensive protection of final circuits against overcurrent's and fault currents. Switches and disconnects circuits. Snap action for low-wear switching of the contacts. Mechanically isolated red indicator in case of fault tripping of the miniature circuit breaker or tripping due to a fault current. Clear switch position indication via green marking on the device's switch knob. Test button for regular function testing. Trip unit technology: thermomagnetic.
Control type is toggle switch
Local signaling is ON, OFF, fault trip
Assembly mode is attachable
Mounting bracket is DIN rail
Related links
- Schneider Electric RCBO 30 mA Trip Sensitivity
- Schneider Electric RCBO 100 mA Trip Sensitivity
- Schneider Electric RCBO 30 mA Trip Sensitivity
- Schneider Electric RCBO 4-Pole Type B A9d Range
- Schneider Electric RCBO 2-Pole Type C iC60 Range
- Schneider Electric RCBO 2-Pole Type C iC60 Range
- Schneider Electric 30 mA Trip Sensitivity
- Siemens RCBO 2-Pole Class B 5SV1 Range