3M 3302 Series Flat Cable, Stranded, 1.27 mm Pitch, 9, 30.48 m Length
- RS Stock No.:
- 120-8485
- Distrelec Article No.:
- 304-08-840
- Mfr. Part No.:
- 3302-9
- Brand:
- 3M
Subtotal (1 reel of 30 metres)*
Kr. 818,78
(exc. VAT)
Kr. 1 023,48
(inc. VAT)
FREE delivery for online orders over 750,00 kr
In Stock
- 2 unit(s) ready to ship
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Reel(s) | Per Reel | Per Metre* |
|---|---|---|
| 1 + | Kr. 818,78 | Kr. 27,293 |
*price indicative
- RS Stock No.:
- 120-8485
- Distrelec Article No.:
- 304-08-840
- Mfr. Part No.:
- 3302-9
- Brand:
- 3M
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | 3M | |
| Product Type | Flat Cable | |
| Cable Type | Stranded | |
| Pitch | 1.27mm | |
| Voltage | 300V | |
| Screened/Unscreened | Unscreened | |
| American Wire Gauge | 28AWG | |
| Number of Conductors | 9 | |
| Conductor Type | Stranded | |
| Jacket Material | Polyvinyl Chloride | |
| Series | 3302 | |
| Cable Length | 30.48m | |
| Standards/Approvals | UL | |
| Jacket Colour | Multicolour | |
| Hi-Flex | No | |
| Fire Behaviour | VW-1 | |
| Conductor Material | Tin Copper Wire | |
| Minimum Operating Temperature | -20°C | |
| Core Strands | 7 | |
| Maximum Operating Temperature | 105°C | |
| Select all | ||
|---|---|---|
Brand 3M | ||
Product Type Flat Cable | ||
Cable Type Stranded | ||
Pitch 1.27mm | ||
Voltage 300V | ||
Screened/Unscreened Unscreened | ||
American Wire Gauge 28AWG | ||
Number of Conductors 9 | ||
Conductor Type Stranded | ||
Jacket Material Polyvinyl Chloride | ||
Series 3302 | ||
Cable Length 30.48m | ||
Standards/Approvals UL | ||
Jacket Colour Multicolour | ||
Hi-Flex No | ||
Fire Behaviour VW-1 | ||
Conductor Material Tin Copper Wire | ||
Minimum Operating Temperature -20°C | ||
Core Strands 7 | ||
Maximum Operating Temperature 105°C | ||
- COO (Country of Origin):
- US
3M 3302 Series Flat Cable, 30.48m Cable Length, 9 Conductors - 3302-9
This flat cable is a multicolour, 9-conductor ribbon designed to connect low-voltage circuits in electronics and automation systems. It provides a compact, organised way to route multiple signal paths in confined assemblies while operating within common industrial temperature ranges and voltage limits.
Features and Benefits:
• 9 conductors for multi-signal runs and simplified wiring
• 28AWG stranded tin copper for enhanced flexibility
• 1.27mm conductor pitch enabling dense connector compatibility
• PVC jacket resistant to routine handling and abrasion
• Rated to 300V supporting low-voltage control circuits
• Operates between -20°C and 105°C for varied environments
• 28AWG stranded tin copper for enhanced flexibility
• 1.27mm conductor pitch enabling dense connector compatibility
• PVC jacket resistant to routine handling and abrasion
• Rated to 300V supporting low-voltage control circuits
• Operates between -20°C and 105°C for varied environments
Applications
• Suitable for internal wiring of control panels and modules
• Ideal for ribbon-style connections to header connectors
• Used for signal harnessing in automation equipment
• Can be used for wiring in test rigs and bench instrumentation
• Used with cable routing channels in mechanical assemblies
• Ideal for ribbon-style connections to header connectors
• Used for signal harnessing in automation equipment
• Can be used for wiring in test rigs and bench instrumentation
• Used with cable routing channels in mechanical assemblies
How many strands are in each conductor and why does that matter?
Each conductor contains seven strands, which increases flexibility and reduces breakage risk during repeated movement.
Is the cable screened for noise suppression?
The construction is unscreened, so external screening or earthed trays are recommended where EMI mitigation is required.
What fire performance does the jacket provide?
The jacket meets VW-1 flame test behaviour, offering improved flame resistance for typical installations.
What material composes the conductor and how does that affect soldering?
Conductors are tinned copper, which aids solderability and reduces surface oxidation compared with bare copper.
Approvals
UL; CSA
Warning
These cables are not to be regarded as power cables or cables for the direct connection of equipment to mains power supplies.
Related links
- HellermannTyton Connectivity Duplex Fibre Optic Patch Panel
- Siemens SIMATIC S7-1200 Series PLC CPU for Use with SIMATIC S7-1200 Series Digital, Relay
- Herga General Purpose Momentary Foot Switch - Thermoplastic Case Material 3 A@ 250 V ac Contact Current, 250V
- Littelfuse Through Hole Gas Discharge Tube
- RS PRO Silver Aluminium Profile Strut 8mm Groove, 1000mm Length
- RS PRO PT100 RTD Sensor 100mm Long Probe, Class A +200°C Max
- Carling Technologies Illuminated DPDT, On-(On) Rocker Switch Panel Mount
- Motorola Talkabout T82 Extreme 16 Channel Walkie Talkies
