Schneider Electric TeSys TeSyS GB2 Thermal Circuit Breaker - 1-Pole, DIN Rail, 5 A Current Rating, 1.5 kA, 110 V ac, 48
- RS Stock No.:
- 323-9037
- Mfr. Part No.:
- GB2CD10
- Brand:
- Schneider Electric
Subtotal (1 unit)*
Kr. 554,61
(exc. VAT)
Kr. 693,26
(inc. VAT)
FREE delivery for online orders over 500,00 kr
In Stock
- 6 unit(s) ready to ship
- Plus 29 unit(s) ready to ship from another location
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
|---|---|
| 1 + | Kr. 554,61 |
*price indicative
- RS Stock No.:
- 323-9037
- Mfr. Part No.:
- GB2CD10
- Brand:
- Schneider Electric
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Schneider Electric | |
| Current Rating | 5 A | |
| Product Type | Thermal Circuit Breaker | |
| Range | TeSys | |
| Number of Poles | 1 | |
| Series | TeSyS GB2 | |
| Width | 15 mm | |
| Mount Type | DIN Rail | |
| Terminal Type | Screw | |
| Tripping Mechanism | Thermal Magnetic | |
| Reset Actuator Type | Toggle Switch | |
| Depth | 70mm | |
| Height | 80mm | |
| Standards/Approvals | CE, RoHS | |
| Rated AC Voltage | 110 V ac | |
| Break Time | Medium | |
| Rated DC Voltage | 48 V dc | |
| Breaking Capacity | 1.5kA | |
| Select all | ||
|---|---|---|
Brand Schneider Electric | ||
Current Rating 5 A | ||
Product Type Thermal Circuit Breaker | ||
Range TeSys | ||
Number of Poles 1 | ||
Series TeSyS GB2 | ||
Width 15 mm | ||
Mount Type DIN Rail | ||
Terminal Type Screw | ||
Tripping Mechanism Thermal Magnetic | ||
Reset Actuator Type Toggle Switch | ||
Depth 70mm | ||
Height 80mm | ||
Standards/Approvals CE, RoHS | ||
Rated AC Voltage 110 V ac | ||
Break Time Medium | ||
Rated DC Voltage 48 V dc | ||
Breaking Capacity 1.5kA | ||
Non Compliant with RoHS
- COO (Country of Origin):
- FR
Schneider Electric GB2 Series Thermal Circuit Breaker, 5A Current, 250/277V Rated AC Voltage - GB2CD10
This thermal circuit-breaker provides overcurrent protection for control and automation networks, combining thermal and magnetic trip elements for temperature-dependent and short-circuit interruption. It is intended for DIN-rail mounting in electrical panels and offers a Compact form factor for space-constrained installations.
Features & Benefits
• 5A rated current for stable circuit protection under nominal load
• 2 kA breaking capacity for handling short-circuit interruptions
• Thermal‑magnetic trip delivers both overload and fault response
• Toggle reset enables Rapid manual reclosure after trip
• Supports 250/277V AC and 48V DC for mixed supply systems
• Cable‑terminal connections accept 0.75 to 6mm² conductors for flexible wiring
• 2 kA breaking capacity for handling short-circuit interruptions
• Thermal‑magnetic trip delivers both overload and fault response
• Toggle reset enables Rapid manual reclosure after trip
• Supports 250/277V AC and 48V DC for mixed supply systems
• Cable‑terminal connections accept 0.75 to 6mm² conductors for flexible wiring
Applications
• Suitable for motor control circuits in factory automation panels
• Ideal for control cabinets in building services installations
• Used with DC control supplies at 48V for signalling circuits
• Can be used for replacement or modular expansion on DIN rails
• Suitable for electrical distribution in small machinery control
• Ideal for control cabinets in building services installations
• Used with DC control supplies at 48V for signalling circuits
• Can be used for replacement or modular expansion on DIN rails
• Suitable for electrical distribution in small machinery control
How is the device mounted and positioned in an enclosure?
It clips onto standard rails and is designed for both horisontal and vertical mounting positions to suit panel layouts.
What electrical endurance can be expected under switching operations?
Mechanical and electrical life are both rated to 8,000 cycles, supporting frequent switching in control applications.
What connections are required for flexible conductors?
Flexible cables may be used with appropriate cable end ferrules
torque for connections is 1.2 N·m.
How does the product behave under impulse conditions?
It withstands impulse voltages up to 4 kV, providing resilience against transient surges in industrial environments.
What environmental ranges will it operate within?
Operational ambient temperature spans −20 to 60 °C and it is rated for altitudes up to 3,000 m.
Standards
IEC947-2
Related links
- Schneider Electric TeSys GB2 Thermal Circuit Breaker - 1-Pole 500 mA Current Rating 110 V ac, 48 V
- Schneider Electric TeSys GB2 Thermal Circuit Breaker - 2-Pole 500 mA Current Rating 110 V ac, 48 V
- Schneider Electric TeSys GB2 Thermal Circuit Breaker - 1-Pole 4 A Current Rating 110 V ac, 48 V dc
- Schneider Electric TeSys GB2 Thermal Circuit Breaker - 1-Pole 1 A Current Rating 110 V ac, 48 V dc
- Schneider Electric TeSys GB2 Thermal Circuit Breaker - 1-Pole 12 A Current Rating 110 V ac, 48 V dc
- Schneider Electric TeSys GB2 Thermal Circuit Breaker - 1-Pole 8 A Current Rating 110 V ac, 48 V dc
- Schneider Electric TeSys GB2 Thermal Circuit Breaker - 2-Pole 2 A Current Rating 110 V ac, 48 V dc
- Schneider Electric TeSys GB2 Thermal Circuit Breaker - 1-Pole 3 A Current Rating 110 V ac, 48 V dc