Omron H3Y-4 Series DIN Rail Timer Relay, 4-Contact, 24 V 24V ac, 2 to 60 s, 1-Function, 4PDT Switch Configuration
- RS Stock No.:
- 340-415
- Mfr. Part No.:
- H3Y-4 DC24 60S
- Brand:
- Omron
Bulk discount available
Subtotal (1 unit)*
Kr. 1 025,15
(exc. VAT)
Kr. 1 281,44
(inc. VAT)
FREE delivery for online orders over 750,00 kr
In Stock
- 19 unit(s) ready to ship
- Plus 1 unit(s) shipping from 18 May 2026
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
|---|---|
| 1 - 24 | Kr. 1 025,15 |
| 25 - 49 | Kr. 973,87 |
| 50 + | Kr. 943,14 |
*price indicative
- RS Stock No.:
- 340-415
- Mfr. Part No.:
- H3Y-4 DC24 60S
- Brand:
- Omron
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Omron | |
| Product Type | Timer Relay | |
| Mount Type | DIN Rail | |
| Function | Swedish Pipe, Multifunction, ON Delay | |
| Time Range | 2 to 60 s | |
| Number of Contacts | 4 | |
| Number of Timer Functions | 1 | |
| Switching Voltage | 250V ac | |
| Contact Configuration | 4PDT | |
| IP Rating | IP40 | |
| Minimum Operating Temperature | -10°C | |
| Supply AC Voltage | 24V ac | |
| Contact Current | 5A | |
| Supply DC Voltage | 24 V | |
| Terminal Type | Plug-In | |
| Maximum Operating Temperature | 50°C | |
| Height | 63mm | |
| Standards/Approvals | UL 508, s to EN 61812-1 and IEC 60664-1, CCC:GB/T 14048.5, Lloyds, CSA C22.2 No. 14 | |
| Length | 28mm | |
| Width | 21.5mm | |
| Series | H3Y-4 | |
| Select all | ||
|---|---|---|
Brand Omron | ||
Product Type Timer Relay | ||
Mount Type DIN Rail | ||
Function Swedish Pipe, Multifunction, ON Delay | ||
Time Range 2 to 60 s | ||
Number of Contacts 4 | ||
Number of Timer Functions 1 | ||
Switching Voltage 250V ac | ||
Contact Configuration 4PDT | ||
IP Rating IP40 | ||
Minimum Operating Temperature -10°C | ||
Supply AC Voltage 24V ac | ||
Contact Current 5A | ||
Supply DC Voltage 24 V | ||
Terminal Type Plug-In | ||
Maximum Operating Temperature 50°C | ||
Height 63mm | ||
Standards/Approvals UL 508, s to EN 61812-1 and IEC 60664-1, CCC:GB/T 14048.5, Lloyds, CSA C22.2 No. 14 | ||
Length 28mm | ||
Width 21.5mm | ||
Series H3Y-4 | ||

Omron H3Y-4 Series Timer Relay, 24V Supply Voltage, 2 to 60s Time Range - H3Y-4 DC24 60S
This timer relay provides time-delayed switching for control and automation tasks, delivering selectable postponement of contact engagement in electrical systems. It is designed for DIN-rail mounting and plug-in termination, making it suitable for panel-based installations where timed ON-delay control is required.
Features and Benefits:
• 2–60 s adjustable timing for precise delay control
• 4PDT contact arrangement enabling multiple-circuit switching
• 5A contact current to handle moderate-load circuits
• 24V AC/DC supply compatibility for flexible power sources
• 250V AC switching capability for common industrial voltages
• IP40 enclosure rating for protected indoor panel use
• 4PDT contact arrangement enabling multiple-circuit switching
• 5A contact current to handle moderate-load circuits
• 24V AC/DC supply compatibility for flexible power sources
• 250V AC switching capability for common industrial voltages
• IP40 enclosure rating for protected indoor panel use
Applications
• Suitable for sequential motor-start control in automation panels
• Ideal for timed lighting circuits in control cabinets
• Used for interlock timing in electrical distribution systems
• Can be used for process-delay functions in manufacturing equipment
• Ideal for timed lighting circuits in control cabinets
• Used for interlock timing in electrical distribution systems
• Can be used for process-delay functions in manufacturing equipment
What mounting method does it use for panel integration?
It is configured for DIN-rail mounting and uses plug-in terminals to facilitate quick installation and replacement in control racks.
How does ambient temperature affect operation limits?
It is designed to operate between -10°C and 50°C, outside of which timing accuracy and component life may be affected.
What approvals support its use in industrial installations?
It holds approvals to standard industrial safety and performance specifications including UL508 and CSA C22.2 No.14 as well as relevant EN and IEC standards.
Which contact configuration allows simultaneous control of multiple circuits?
The unit incorporates four changeover contacts, permitting concurrent switching of separate circuits from a single timing event.
Approvals
UL, CSA
Standards
EN 50081-2, EN50082-2, VDE0435/P2021, VDE0110
Related links
- Omron H3Y-4 Series DIN Rail Timer Relay 125 V dc 24V ac 1-Function, 4PDT Switch Configuration
- Omron H3Y-4 Series DIN Rail Timer Relay 125 V dc 24V ac 1-Function, 4PDT Switch Configuration
- Omron H3Y-4 Series DIN Rail Timer Relay 125 V dc 24V ac 1-Function, 4PDT Switch Configuration
- Omron H3Y-4 Series DIN Rail Timer Relay 24 V dc 24V ac 1-Function, 4PDT Switch Configuration
- Omron H3Y-4 Series DIN Rail Timer Relay 24 V dc 24V ac 1-Function, 4PDT Switch Configuration
- Omron H3Y-4 Series DIN Rail Timer Relay 125 V dc 24V ac 1-Function, 4PDT Switch Configuration
- Omron H3Y-4 Series DIN Rail Timer Relay 125 V dc 24V ac 1-Function, 4PDT Switch Configuration
- Omron H3Y-4 Series DIN Rail Timer Relay 125 V dc 24V ac 1-Function, 4PDT Switch Configuration
