Alpha Wire Alpha Essentials Data & Bus Cable Series Data Cable, 1 Pairs, 0.33 mm², 305 m, Orange Sheath Polypropylene
- RS Stock No.:
- 749-1573
- Mfr. Part No.:
- 6460 OR001
- Brand:
- Alpha Wire
Subtotal (1 reel of 305 metres)*
Kr. 6 119,48
(exc. VAT)
Kr. 7 649,35
(inc. VAT)
FREE delivery for online orders over 750,00 kr
In Stock
- 2 unit(s) ready to ship
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Reel(s) | Per Reel | Per Metre* |
|---|---|---|
| 1 + | Kr. 6 119,48 | Kr. 20,064 |
*price indicative
- RS Stock No.:
- 749-1573
- Mfr. Part No.:
- 6460 OR001
- Brand:
- Alpha Wire
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Alpha Wire | |
| Number of Pairs | 1 | |
| Product Type | Data Cable | |
| Cross Sectional Area | 0.33mm² | |
| Cable Length | 305m | |
| Jacket Colour | Orange | |
| Outside Diameter | 4.97mm | |
| Jacket Material | Polypropylene | |
| Conductor Type | Copper | |
| Minimum Operating Temperature | -30°C | |
| Maximum Operating Temperature | 105°C | |
| Standards/Approvals | CSA, UL, CE | |
| Conductor Material | Tin Copper Wire | |
| Series | Alpha Essentials Data & Bus Cable | |
| Core Strands | 7 | |
| Voltage | 300V | |
| Select all | ||
|---|---|---|
Brand Alpha Wire | ||
Number of Pairs 1 | ||
Product Type Data Cable | ||
Cross Sectional Area 0.33mm² | ||
Cable Length 305m | ||
Jacket Colour Orange | ||
Outside Diameter 4.97mm | ||
Jacket Material Polypropylene | ||
Conductor Type Copper | ||
Minimum Operating Temperature -30°C | ||
Maximum Operating Temperature 105°C | ||
Standards/Approvals CSA, UL, CE | ||
Conductor Material Tin Copper Wire | ||
Series Alpha Essentials Data & Bus Cable | ||
Core Strands 7 | ||
Voltage 300V | ||
Belden Alpha Essentials Data & Bus Cable Series Data Cable, 305m Length, Orange Jacket - 6460 OR001
This data cable is a single-pair communication cable designed for industrial and control environments, offering a Durable polypropylene outer jacket and tin-plated copper conductors for signal transmission at system voltages up to 300 V. It is intended for use where a compact, orange‑jacketed cable is required for identification and routing in automation, electronics and electrical installations.
Features & Benefits
• Tin‑plated 7‑strand conductor for improved solderability and corrosion resistance
• 0.33 mm² conductor cross‑section delivering consistent current‑carrying capacity
• Polypropylene jacket resists chemicals and mechanical wear for long service life
• Rated −30 to 105 °C for a wide operating temperature range in harsh conditions
• 300V insulation rating suitable for common control and signalling circuits
• 4.97mm outside diameter for Compact routing in trays and conduit
• 0.33 mm² conductor cross‑section delivering consistent current‑carrying capacity
• Polypropylene jacket resists chemicals and mechanical wear for long service life
• Rated −30 to 105 °C for a wide operating temperature range in harsh conditions
• 300V insulation rating suitable for common control and signalling circuits
• 4.97mm outside diameter for Compact routing in trays and conduit
**Applications**
• Suitable for single‑pair fieldbus and sensor connections in factory automation
• Ideal for control‑panel internal wiring and remote I/O links
• Used for communications between PLCs and distributed modules
• Can be used for low‑voltage signalling in electrical distribution equipment
• Suitable for integration into machine harnesses requiring Orange identification
• Ideal for control‑panel internal wiring and remote I/O links
• Used for communications between PLCs and distributed modules
• Can be used for low‑voltage signalling in electrical distribution equipment
• Suitable for integration into machine harnesses requiring Orange identification
What conductor construction enables flexibility and termination options?
The conductor comprises seven strands of tin‑plated copper, which balances flexibility for routing with good termination by crimping or soldering.
How does the jacket material affect installation in industrial settings?
The polypropylene outer sheath provides abrasion resistance and chemical resilience, aiding installation through cable trays and reducing damage from routine handling.
What electrical environments is the cable suited for regarding voltage and approvals?
It is designed for 300V systems and carries approvals under UL, CSA and CE standards relevant to communication and control wiring.
How does temperature rating inform selection for severe ambient conditions?
With an operating span from −30 to 105 °C, it meets the requirements for applications exposed to low‑temperature storage and elevated operational heat without losing electrical integrity.
In what way does the cable colour and construction support industrial identification and maintenance?
The Orange jacket provides clear Visual identification for data and bus circuits, simplifying fault‑finding and segregation from power wiring.
Related links
- Alpha Wire Alpha Essentials Data & Bus Cable Series Data Cable 0.33 mm² Orange Sheath Polypropylene
- Alpha Wire Alpha Essentials Data & Bus Cable Series Data Cable 0.9 mm² Orange Sheath Polypropylene
- Alpha Wire Alpha Essentials Data & Bus Cable Series Data Cable 0.456 mm² Black Sheath Polyvinyl
- Alpha Wire Alpha Essentials Data & Bus Cable Series Data Cable 0.32 mm² Violet Sheath Polyvinyl
- Alpha Wire Alpha Essentials Data & Bus Cable Series Data Cable 0.35 mm² Violet Sheath Polyvinyl
- Alpha Wire Alpha Essentials Communication & Control Series Data Cable 0.33 mm² Grey Sheath Polyvinyl
- Alpha Wire Alpha Essentials Data & Bus Cable Series Data Cable 0.462 mm² Black Sheath Polyvinyl
- Alpha Wire Alpha Essentials Data & Bus Cable Series Data Cable 0.456 mm² Black Sheath Polyvinyl