- RS Stock No.:
- 240-8498
- Mfr. Part No.:
- IRV300-12W80HR-C
- Brand:
- Murata
16 In stock for same day dispatch
Added
Price Each
Kr. 4 880,04
(exc. VAT)
Kr. 6 100,05
(inc. VAT)
Units | Per unit |
1 - 4 | Kr. 4 880,04 |
5 - 9 | Kr. 4 733,63 |
10 - 24 | Kr. 4 587,22 |
25 - 49 | Kr. 4 440,81 |
50 + | Kr. 4 294,40 |
- RS Stock No.:
- 240-8498
- Mfr. Part No.:
- IRV300-12W80HR-C
- Brand:
- Murata
Technical Reference
Legislation and Compliance
- COO (Country of Origin):
- CN
Product Details
The Murata IRV300 series is a 300W stand alone, system level, chassis mount isolated DC-DC converter. The converter features an ultra wide input designed to accept nominal battery voltages from 24V to 110V in a single product. The IRV300 is ideally suited for railway applications, meeting EN50155 standard in a single package. The output voltage has a wide trim range up to +15% of Vnom, and features a constant current output profile ideally suited for high inductive/capacitive loading.
Up to 300 Watts total output power
Certified to railway standards EN 50155 and EN 50121-3-2
High efficiency up to 92%, typical
Tight line and load regulation
Low ripple and noise
Extensive self-protection shut down features, including over temperature shutdown
Output voltage adjustable
Green LED power indicator
Remote on/off and PUL
Optional ORing feature for redundant or parallel operation with droop
Optional hold-up feature
Certified to railway standards EN 50155 and EN 50121-3-2
High efficiency up to 92%, typical
Tight line and load regulation
Low ripple and noise
Extensive self-protection shut down features, including over temperature shutdown
Output voltage adjustable
Green LED power indicator
Remote on/off and PUL
Optional ORing feature for redundant or parallel operation with droop
Optional hold-up feature
Specifications
Attribute | Value |
---|---|
Output Voltage | 12V dc |
Input Voltage Range | 16.8 → 160 V dc |
Power Rating | 300W |
Input Voltage Nominal | 110 V dc |
Mounting Type | Chassis Mount |
Isolated | Yes |
Output Voltage Adjustment Range | 15% |
Isolation Voltage | 4.25kV dc |
Railway Approved | Yes |
Series | IRV300 |
Medical Approved | No |