Endress+Hauser DMA15 Series Flow Meter 0.05L/min to 35L/min, Male, G 1/2, G
- RS Stock No.:
- 256-6151
- Distrelec Article No.:
- 303-51-190
- Mfr. Part No.:
- DMA15-AAABA1
- Brand:
- Endress+Hauser
Image representative of range
Subtotal (1 unit)*
Kr. 4 963,49
(exc. VAT)
Kr. 6 204,36
(inc. VAT)
FREE delivery for online orders over 750,00 kr
In Stock
- 5 unit(s) ready to ship
- Plus 40 unit(s) ready to ship from another location
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
|---|---|
| 1 + | Kr. 4 963,49 |
*price indicative
- RS Stock No.:
- 256-6151
- Distrelec Article No.:
- 303-51-190
- Mfr. Part No.:
- DMA15-AAABA1
- Brand:
- Endress+Hauser
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Endress+Hauser | |
| Product Type | Flow Meter | |
| Connection Thread Size | G 1/2 | |
| Connection Thread Standard | G | |
| Connection Gender | Male | |
| Maximum Operating Temperature | 60°C | |
| Series | DMA15 | |
| Standards/Approvals | CE mark | |
| Wetted Materials | 316L Stainless Steel | |
| Maximum Flow Rate | 35L/min | |
| Minimum Flow Rate | 0.05L/min | |
| Select all | ||
|---|---|---|
Brand Endress+Hauser | ||
Product Type Flow Meter | ||
Connection Thread Size G 1/2 | ||
Connection Thread Standard G | ||
Connection Gender Male | ||
Maximum Operating Temperature 60°C | ||
Series DMA15 | ||
Standards/Approvals CE mark | ||
Wetted Materials 316L Stainless Steel | ||
Maximum Flow Rate 35L/min | ||
Minimum Flow Rate 0.05L/min | ||
- COO (Country of Origin):
- FR
Endress+Hauser DMA15 Series Flow Meter, 35 L/min Maximum Flow Rate, 60°C Maximum Operating Temperature - DMA15-AAABA1
This flow metre measures and reports liquid flow rates for inline process monitoring and control. Built with corrosion-resistant wetted surfaces, it is intended for integration into fluid lines where moderate temperatures and a wide dynamic range of flow—from very low to mid-range—need to be quantified. The unit connects directly into piping systems via a male G-thread fitting and carries the required CE marking for use in regulated environments.
Features and Benefits:
• 316L wetted materials reduce corrosion risk and contamination
• Male G1/2 threaded connection enables straightforward inline installation
• Measures down to 0.05 L/min to capture very low-volume flows accurately
• Supports up to 35 L/min for higher throughput measurements
• Rated for continuous operation at temperatures up to 60°C
• Constructed from 316L stainless steel body for durable service
• Male G1/2 threaded connection enables straightforward inline installation
• Measures down to 0.05 L/min to capture very low-volume flows accurately
• Supports up to 35 L/min for higher throughput measurements
• Rated for continuous operation at temperatures up to 60°C
• Constructed from 316L stainless steel body for durable service
Applications
• Used for dosing control in process skids requiring low-flow precision
• Suitable for pharmaceutical liquid transfer where material compatibility matters
• Used with laboratory and pilot-plant lines needing compact inline measurement
• Ideal for food-sector sampling systems requiring stainless wetted parts
• Suitable for pharmaceutical liquid transfer where material compatibility matters
• Used with laboratory and pilot-plant lines needing compact inline measurement
• Ideal for food-sector sampling systems requiring stainless wetted parts
How does the connection type affect mounting options?
The male G1/2 thread conforms to G-thread standards, permitting straightforward screw-in mounting to compatible flanges or fittings without additional adaptors.
What operating environments suit the device temperature rating?
The maximum operating temperature of 60°C makes it appropriate for warm-process liquids but not for high-temperature steam or hot-oil circuits.
Which materials are exposed to the process fluid and why does that matter?
All wetted surfaces are made from 316L stainless steel, chosen for its chemical resistance and suitability where metal contact with liquids must be minimised.
Can it handle very low metering tasks and higher flow duties in the same installation?
The instrument spans from 0.05 L/min up to 35 L/min, allowing both precision low-flow metering and intermittent higher-flow events without swapping devices.
Related links
- Endress+Hauser DMA15 Series Flow Meter 0.05L/min to 35L/min G 1/2
- Endress+Hauser DMA15 Series Electromagnetic Flowmeter IO-Link Module for Liquid 35L/min Max
- Endress+Hauser DMA50 Series Flow Meter 1.5L/min to 750L/min G 2 In
- Endress+Hauser DMA15 Series Electromagnetic Flowmeter IO-Link Module for Liquid 750L/min Max
- Endress+Hauser DMA15 Series Electromagnetic Flowmeter IO-Link Module for Liquid 75L/min Max
- Endress+Hauser DMA20 Series Electromagnetic Flowmeter Flow Meter for Liquid 75L/min Max
- Endress+Hauser DMA25 Series Electromagnetic Flowmeter Flow Meter for Liquid 150L/min Max
- Endress+Hauser DMA15 Series Electromagnetic Flowmeter IO-Link Module for Liquid 150L/min Max