Fluke 117 Fluke 117 Digital Digital Multimeter True RMS, 10 A ac, 10 A dc, 600 V ac
- RS Stock No.:
- 616-1460
- Distrelec Article No.:
- 176-05-447
- Mfr. Part No.:
- FLUKE 117 EUR
- Brand:
- Fluke
Subtotal (1 unit)*
Kr. 3 075,30
(exc. VAT)
Kr. 3 844,12
(inc. VAT)
FREE delivery for online orders over 750,00 kr
- 140 unit(s) ready to ship
- Plus 87 unit(s) ready to ship from another location
Units | Per unit |
|---|---|
| 1 + | Kr. 3 075,30 |
*price indicative
Calibration Options:
- Calibration Type:
- RSCAL
- RS Stock No.
- 625-0598
Each
Kr. 4 039,00
(exc. VAT)
Kr. 5 048,75
(inc. VAT)
- Calibration Type:
- UKAS
- RS Stock No.
- 625-0605
Each
Kr. 4 359,00
(exc. VAT)
Kr. 5 448,75
(inc. VAT)
- RS Stock No.:
- 616-1460
- Distrelec Article No.:
- 176-05-447
- Mfr. Part No.:
- FLUKE 117 EUR
- Brand:
- Fluke
Select all | Attribute | Value |
|---|---|---|
| Brand | Fluke | |
| Multimeter Type | Digital | |
| Product Type | Multimeter | |
| Resistance Resolution | 100mΩ | |
| Model Number | 117 | |
| Display Type | Digital | |
| Functions Measured | AC Current, AC Voltage, Capacitance, Continuity, DC Current, DC Voltage, Diode Test, Frequency, Resistance | |
| Maximum Resistance Measurement | 40mΩ | |
| Maximum AC Voltage Measurement | 600V ac | |
| Maximum DC Current Measurement | 10A dc | |
| Maximum DC Voltage Measurement | 600V dc | |
| Maximum AC Current Measurement | 10A ac | |
| True RMS | Yes | |
| AC Current Accuracy | ±1.5 % rdg + 3 Digits | |
| AC Voltage Accuracy | ±1 % rdg + 3 Digits | |
| DC Current Accuracy | ±1 % rdg + 3 Digits | |
| DC Voltage Accuracy | ±0.5 % rdg + 2 Digits | |
| AC Current Resolution | 0.001A ac | |
| AC Voltage Resolution | 0.1mV ac | |
| DC Current Resolution | 0.001A ac | |
| DC Voltage Resolution | 0.1 mV dc | |
| Maximum Frequency | 50kHz | |
| Power Source | Battery | |
| Minimum Operating Temperature | -10°C | |
| Resistance Measurement Accuracy | ±1.5 % rdg + 2 Digits | |
| Maximum Operating Temperature | 50°C | |
| Battery Life | 400h | |
| Series | Fluke 117 | |
| Standards/Approvals | CE, N10140, TUV, CSAus, UL, VDE | |
| Length | 167mm | |
| Width | 84mm | |
| Weight | 550g | |
| Height | 46mm | |
| Safety Category Level | CAT III | |
| Battery Type | Alkaline | |
| Safety Category Voltage | 600V | |
| Select all | ||
|---|---|---|
Brand Fluke | ||
Multimeter Type Digital | ||
Product Type Multimeter | ||
Resistance Resolution 100mΩ | ||
Model Number 117 | ||
Display Type Digital | ||
Functions Measured AC Current, AC Voltage, Capacitance, Continuity, DC Current, DC Voltage, Diode Test, Frequency, Resistance | ||
Maximum Resistance Measurement 40mΩ | ||
Maximum AC Voltage Measurement 600V ac | ||
Maximum DC Current Measurement 10A dc | ||
Maximum DC Voltage Measurement 600V dc | ||
Maximum AC Current Measurement 10A ac | ||
True RMS Yes | ||
AC Current Accuracy ±1.5 % rdg + 3 Digits | ||
AC Voltage Accuracy ±1 % rdg + 3 Digits | ||
DC Current Accuracy ±1 % rdg + 3 Digits | ||
DC Voltage Accuracy ±0.5 % rdg + 2 Digits | ||
AC Current Resolution 0.001A ac | ||
AC Voltage Resolution 0.1mV ac | ||
DC Current Resolution 0.001A ac | ||
DC Voltage Resolution 0.1 mV dc | ||
Maximum Frequency 50kHz | ||
Power Source Battery | ||
Minimum Operating Temperature -10°C | ||
Resistance Measurement Accuracy ±1.5 % rdg + 2 Digits | ||
Maximum Operating Temperature 50°C | ||
Battery Life 400h | ||
Series Fluke 117 | ||
Standards/Approvals CE, N10140, TUV, CSAus, UL, VDE | ||
Length 167mm | ||
Width 84mm | ||
Weight 550g | ||
Height 46mm | ||
Safety Category Level CAT III | ||
Battery Type Alkaline | ||
Safety Category Voltage 600V | ||
RoHS Status: Exempted
Fluke Multimeter, 600V Maximum DC Voltage, 20A Maximum AC Current - FLUKE 117 EUR
Features & Benefits
• Measures up to 600V and 20A for broad system coverage
• Frequency response to 50kHz for high‑frequency diagnostics
• Low‑resistance measurement down to 40mΩ for tight contact checks
• Diode and continuity tests detect opens and shorts quickly
• Battery life approximately 400 h for prolonged field operation
**Applications**
• Ideal for commissioning AC and DC power systems
• Used for capacitor testing and circuit tuning in electronics
• Can be used for motor drive frequency verification up to 50kHz
• Suitable for testing clamp‑free current scenarios up to 20A
What protection ratings and approvals does it have for industrial use?
How does the meter handle inrush or short‑duration current measurements?
What display and measurement update behaviour should I expect?
Which battery type is required and what are operating environment limits?
Can it measure capacitance and temperature?
Note
Contents
Related links
- HellermannTyton Connectivity Duplex Fibre Optic Patch Panel
- Siemens SIMATIC S7-1200 Series PLC CPU for Use with SIMATIC S7-1200 Series Digital, Relay
- Herga General Purpose Momentary Foot Switch - Thermoplastic Case Material 3 A@ 250 V ac Contact Current, 250V
- Littelfuse Through Hole Gas Discharge Tube
- RS PRO Silver Aluminium Profile Strut 8mm Groove, 1000mm Length
- RS PRO PT100 RTD Sensor 100mm Long Probe, Class A +200°C Max
- Carling Technologies Illuminated DPDT, On-(On) Rocker Switch Panel Mount
- Motorola Talkabout T82 Extreme 16 Channel Walkie Talkies