Lapp NYY-J 1.5 mm² 3 Core Power Cable, Black PVC, 50m
- RS Stock No.:
- 721-0689
- Mfr. Part No.:
- 15500013
- Brand:
- Lapp
Image representative of range
Subtotal (1 reel of 50 metres)*
Kr.2 001 38
(exc. VAT)
Kr.2 501 72
(inc. VAT)
FREE delivery for online orders over 500,00 kr
In Stock
- 7 unit(s) ready to ship
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Reel(s) | Per Reel | Per Metre* |
|---|---|---|
| 1 + | Kr. 2 001,38 | Kr. 40,028 |
*price indicative
- RS Stock No.:
- 721-0689
- Mfr. Part No.:
- 15500013
- Brand:
- Lapp
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Lapp | |
| Cross Sectional Area | 1.5 mm² | |
| Number of Cores | 3 | |
| Sheath Colour | Black | |
| Length | 50m | |
| Current Rating | 19 A | |
| Sheath Material | PVC | |
| Outer Diameter | 12mm | |
| CPR Certification | Eca | |
| Voltage Rating | 1 kV, 600 V | |
| Conductor Strand Type | Solid | |
| Conductor Material | Bare Copper | |
| Maximum Operating Temperature | +50°C | |
| Size of Strands | 1.38 mm | |
| Series | NYY-J | |
| Core Strands | 1.38 mm | |
| Insulation Material | PVC | |
| Fire Behaviour | Flame Retardant | |
| American Wire Gauge | 15 AWG | |
| Conductor Resistance | 12.1 Ω/km | |
| Minimum Operating Temperature | -5°C | |
| Standards Met | Euroclass Eca | |
| Select all | ||
|---|---|---|
Brand Lapp | ||
Cross Sectional Area 1.5 mm² | ||
Number of Cores 3 | ||
Sheath Colour Black | ||
Length 50m | ||
Current Rating 19 A | ||
Sheath Material PVC | ||
Outer Diameter 12mm | ||
CPR Certification Eca | ||
Voltage Rating 1 kV, 600 V | ||
Conductor Strand Type Solid | ||
Conductor Material Bare Copper | ||
Maximum Operating Temperature +50°C | ||
Size of Strands 1.38 mm | ||
Series NYY-J | ||
Core Strands 1.38 mm | ||
Insulation Material PVC | ||
Fire Behaviour Flame Retardant | ||
American Wire Gauge 15 AWG | ||
Conductor Resistance 12.1 Ω/km | ||
Minimum Operating Temperature -5°C | ||
Standards Met Euroclass Eca | ||
Lapp Fixed Installation Power Cable - NYY-J
From Lapp, this NYY-J cable is a widely-used power and control cable that is often found in domestic and commercial electrical wiring. As well as being used in fixed installations, the cable is designed to be used for direct burial, and burial in concrete, providing the operating temperature is adhered to.
The cable is bare copper single core with PVC with a filling compounds over the core assembly. The PVC sheath is flame retardant and robust, allowing the cable to be used in dry, damp and wet interiors. NYY-J cable is also able very resistant to UV, and so is able to be used outdoors.
Features and Benefits
Bare copper conductors
PVC-based outer sheath
Suitable for outdoor use
Flame-retardant according IEC 60332-1-2
Above, below, flush and recess routing
Operating temperature during installation: -5°C to +50°C
Operating temperature in a fixed installation: -40°C to +70°C
Applications
Able to be installed in open air and underground, NYY-J cable presents a versatile power cable that should be used in where the risk of mechanical damage is unlikely. As such it can be used in brickwork and concrete, proving the concrete is not shaken, vibrated or compressed. Lapp NYY-J able is often used in;
Power stations
Distributor boards
Subscriber networks
The cable is bare copper single core with PVC with a filling compounds over the core assembly. The PVC sheath is flame retardant and robust, allowing the cable to be used in dry, damp and wet interiors. NYY-J cable is also able very resistant to UV, and so is able to be used outdoors.
Features and Benefits
Bare copper conductors
PVC-based outer sheath
Suitable for outdoor use
Flame-retardant according IEC 60332-1-2
Above, below, flush and recess routing
Operating temperature during installation: -5°C to +50°C
Operating temperature in a fixed installation: -40°C to +70°C
Applications
Able to be installed in open air and underground, NYY-J cable presents a versatile power cable that should be used in where the risk of mechanical damage is unlikely. As such it can be used in brickwork and concrete, proving the concrete is not shaken, vibrated or compressed. Lapp NYY-J able is often used in;
Power stations
Distributor boards
Subscriber networks
Power Cable
Related links
- Lapp NYY-J 1.5 mm² 4 Core Power Cable 50m
- Lapp NYY-J Standard 2.5 mm² 3 Core Power Cable 50m
- Lapp NYY-J 10 mm² 3 Core Power Cable 50m
- Lapp NYY-J 6 mm² 3 Core Power Cable 50m
- Lapp NYY-J 16 mm² 3 Core Power Cable 50m
- Lapp NYY-J 4 mm² 3 Core Power Cable 50m
- RS PRO NYY-J 1.5 mm² 3 Core Power Cable 50m
- Lapp NYY-J 2.5 mm² 5 Core Power Cable 50m