RS PRO IPM3600N Power Quality Analyser

Technical Reference
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): TW
Product Details

RS PRO IPM3600 Power Quality Tester

RS PRO IPM3600 is a great value 3-phase power analyser for portable measurement and diagnosing power problems in electrical installations and power circuits within public mains supplies. The software allows the power analyser to: communicate with a PC via the USB port; upload data from the tester and store to the PC hard disk; display recorded reading in a graphical format on the PC; convert the recorded data into Excel format for analysis; display signal harmonics in graphical format on the PC; clear the data readings stored in the tester.


Problems that can occur due to power quality problems include automatic resets, data errors, equipment failures, memory loss and overheating electrical distribution systems. These problems in workplaces have a negative impact on production, can damage sensitive equipment and increase costs. Bad power quality can also increase energy consumption.

Features and Benefits

  • 10 display, easy-to-view LCD screen

  • Connectors for 4 current sensing clamps

  • 1 P2W, 1 P3W, 3 P3W2M & 3 P4W power measurement

  • True RMS sensing

  • Power KW, KVAR, KVA, PF, θ, Hz & Energy KWh, KVARh & KVAh measurement

  • Phase sequence indicator function

  • Backlight display function

  • Manual data memory and read (99 sets)

  • Data logging (504 KB memory, 20 000 sets)

  • Programmable trigger - points and start / stop time

  • USB optical interface with three phase voltage / current waveform display and harmonic analysis

  • Easy-to-use push-button operation

  • Lightweight, portable design

Areas of Application

Power quality analysers are multi-function instruments that measure and test various things such as direct current, alternating current, AC-voltage, DC-voltage, harmonics and much more depending on the model. The data can then be logged and analysed with the software supplied with the device. Areas include:

  • Electrical installations

  • Power circuits

  • Analysing and troubleshooting power quality issues

  • Improving power efficiency

  • Managing energy costs

  • Analysing harmonics

  • Optimising power system performance

  • Improving power quality

  • Analysing system data to design optimal upgrades

FAQs

What is meant by power quality problems?


Power quality refers to the ability of electrical equipment to consume the energy being supplied to it in other words to provide stable power. There can be various power quality issues and the most common include electrical harmonics, poor power factor, voltage instability and imbalance impact on the efficiency of electrical equipment.

Supplied with

User manual, software on CD Rom, deluxe carrying case, AA 1.5 V battery (x8), AC adapter (110 V > 12 V ; 220 V > 12 V), current clamp transducer (x4, cable length 3 m), crocodiles test leads (blue, yellow, red, black - wire length 3 m)

Specifications
Attribute Value
Absolute Maximum Current Measurement 999.9A
Absolute Maximum Power Measurement 999.9kW
Number of Phases 3
Maximum Voltage 999.9V
Best Voltage Measurement Accuracy ±0.3 % ± 10 Digits
Best Current Measurement Accuracy ±0.5 % ± 15 Digits
Display Type LCD
Measurement Type AC Current, AC Voltage, AC Wattage, Frequency, Harmonic, Phase Angle, Power Energy, Power Factor, Three Phase Sequency Detection
Interface Type USB
Power Source Battery
Battery Type AA
Dimensions 116 x 54 x 235mm
Maximum Frequency 60Hz
Maximum Operating Temperature +50°C
Minimum Operating Temperature 0°C
Model Number p IPM3600N
Length 116mm
Width 54mm
Height 235mm
6 In stock for delivery within 1 working days
Price Each
kr 9 650,22
(exc. VAT)
kr 12 062,78
(inc. VAT)
Units
Per unit
1 +
kr 9 650,22
Related Products
Three-phase energy and power failure analyser. Power and ...
Description:
Three-phase energy and power failure analyser. Power and energy analysis in supply networks. Harmonics analysis in accordance with EN 61000-4-7Network quality in accordance with EN50160 with statistical bar chart. Flicker analysis as per standard EN 61000-4-15Recording of power-on operations and ...
HMC8015 is the first compact tester for AC/DC ...
Description:
HMC8015 is the first compact tester for AC/DC load and standby current characterisation to enable measurements without extra requirements such as computers or remote infrastructure. It features a numerical and graphical display with 26 key parameters. Its performance and compliance ...
The 6813C AC power source/analyser from Keysight is ...
Description:
The 6813C AC power source/analyser from Keysight is a performance AC test soloution with 1750 VA maximum output power and a built in arbitrary waveform generator. 20 Vrms test signal (Option 001)High-speed measurements: 5.6 ms201 points list sweep. Versatile PC ...
The HM6050-2 line impedance stabilization network (LISN) is ...
Description:
The HM6050-2 line impedance stabilization network (LISN) is basically a filter network. Measurement of Line-conducted Interference within the Range from 9k. Hz…30MHz (CISPR 16)Selectable Transient Limiter. Artificial Hand Connector A lowpass filter connects the DUT to the AC power lines.The ...