Fluke 374 FC Clamp Meter, 600 A dc 600 A ac 1000 V dc 1000 V ac CAT III, CAT IV Non-Contact Voltage Detector
- RS Stock No.:
- 905-5911
- Distrelec Article No.:
- 300-37-361
- Mfr. Part No.:
- FLUKE-374 FC
- Brand:
- Fluke
Subtotal (1 unit)*
Kr. 6 520,00
(exc. VAT)
Kr. 8 150,00
(inc. VAT)
FREE delivery for online orders over 750,00 kr
- 43 unit(s) ready to ship
- Plus 72 unit(s) ready to ship from another location
Units | Per unit |
|---|---|
| 1 + | Kr. 6 520,00 |
*price indicative
- RS Stock No.:
- 905-5911
- Distrelec Article No.:
- 300-37-361
- Mfr. Part No.:
- FLUKE-374 FC
- Brand:
- Fluke
Select all | Attribute | Value |
|---|---|---|
| Brand | Fluke | |
| Product Type | Clamp Meter | |
| Maximum DC Current Measurement | 600A dc | |
| Resistance Resolution | 100mΩ | |
| Maximum AC Voltage Measurement | 1000V ac | |
| Maximum DC Voltage Measurement | 1000V dc | |
| Maximum Resistance Measurement | 6kΩ | |
| Model Number | 374 FC | |
| DC Voltage Accuracy | ±1 % rdg + 5 Digits | |
| Clamp Meter Type | AC/DC Clamp Meter | |
| DC Current Accuracy | ±2 % rdg + 5 Digits | |
| Resistance Measurement Accuracy | ±1 % rdg + 5 Digits | |
| AC Current Resolution | 100mA | |
| Minimum Operating Temperature | -10°C | |
| AC Voltage Accuracy | ±1.5 % rdg + 5 Digits | |
| AC Voltage Resolution | 100mV ac | |
| Maximum Jaw Opening | 34mm | |
| DC Voltage Resolution | 100 mV dc | |
| AC Current Accuracy | ±2 % rdg + 5 Digits | |
| DC Current Resolution | 100mA | |
| Maximum Operating Temperature | 50°C | |
| Length | 249mm | |
| Width | 85mm | |
| Weight | 395g | |
| Height | 45mm | |
| Standards/Approvals | IEC 61010-1IEC 61010-2-032IEC 61010-2-033IEC 60529: IP30FCC ID:T68-FBLEIC:6627A-FBLEIEC 61326-1IEC 61326-2-2CISPR 11 | |
| True RMS | Yes | |
| Functions Measured | Temperature, Resistance, DC Current, AC Voltage, AC Current, DC Voltage | |
| Battery Type | AA IEC LR06 | |
| Power Source | Battery | |
| Safety Category Voltage | 1000V | |
| Maximum AC Current Measurement | 600A ac | |
| Non-Contact Voltage Detector | Yes | |
| Safety Category Level | CAT III, CAT IV | |
| Display Type | LCD Backlight | |
| Select all | ||
|---|---|---|
Brand Fluke | ||
Product Type Clamp Meter | ||
Maximum DC Current Measurement 600A dc | ||
Resistance Resolution 100mΩ | ||
Maximum AC Voltage Measurement 1000V ac | ||
Maximum DC Voltage Measurement 1000V dc | ||
Maximum Resistance Measurement 6kΩ | ||
Model Number 374 FC | ||
DC Voltage Accuracy ±1 % rdg + 5 Digits | ||
Clamp Meter Type AC/DC Clamp Meter | ||
DC Current Accuracy ±2 % rdg + 5 Digits | ||
Resistance Measurement Accuracy ±1 % rdg + 5 Digits | ||
AC Current Resolution 100mA | ||
Minimum Operating Temperature -10°C | ||
AC Voltage Accuracy ±1.5 % rdg + 5 Digits | ||
AC Voltage Resolution 100mV ac | ||
Maximum Jaw Opening 34mm | ||
DC Voltage Resolution 100 mV dc | ||
AC Current Accuracy ±2 % rdg + 5 Digits | ||
DC Current Resolution 100mA | ||
Maximum Operating Temperature 50°C | ||
Length 249mm | ||
Width 85mm | ||
Weight 395g | ||
Height 45mm | ||
Standards/Approvals IEC 61010-1IEC 61010-2-032IEC 61010-2-033IEC 60529: IP30FCC ID:T68-FBLEIC:6627A-FBLEIEC 61326-1IEC 61326-2-2CISPR 11 | ||
True RMS Yes | ||
Functions Measured Temperature, Resistance, DC Current, AC Voltage, AC Current, DC Voltage | ||
Battery Type AA IEC LR06 | ||
Power Source Battery | ||
Safety Category Voltage 1000V | ||
Maximum AC Current Measurement 600A ac | ||
Non-Contact Voltage Detector Yes | ||
Safety Category Level CAT III, CAT IV | ||
Display Type LCD Backlight | ||
RoHS Status: Exempted
- COO (Country of Origin):
- MY
Fluke Clamp Meter, 600A Maximum AC Current Measurement, 1000V Maximum DC Voltage Measurement - FLUKE-374 FC
Features & Benefits
• 600A jaw range with 2500A flexible-probe compatibility for large conductors
• 1000V measurement capacity with CATIII1000V and CATIV600V safety ratings
• High-accuracy DC current ±2%rdg+5 digits for precise diagnostics
• Resistance and capacitance ranges to 6000Ω and 1000μF for component checks
• Bluetooth wireless output to log and transmit readings remotely
Applications
• Ideal for load balancing and power-quality checks in distribution panels
• Used for preventive maintenance where remote logging reduces exposure
• Can be used for installation verification on 1000V-rated electrical systems
• Used with flexible probes to measure large busbars and multi-core cables
Which batteries power the instrument and how are they replaced?
How does the flexible probe extend measurement capability?
What environmental limits affect operation at elevated humidity?
How does the instrument handle measurements on variable-frequency drives?
What ingress protection and standards apply to storage and transport?
Related links
- Fluke 374 FC Clamp Meter CAT IV Non-Contact Voltage Detector RSCAL
- Fluke 374 FC Clamp Meter CAT IV Non-Contact Voltage Detector UKAS
- Fluke 375 FC Clamp Meter CAT IV Non-Contact Voltage Detector
- Fluke 376 FC Clamp Meter CAT IV Non-Contact Voltage Detector
- Fluke 375 FC Clamp Meter CAT IV Non-Contact Voltage Detector UKAS
- Fluke 375 FC Clamp Meter CAT IV Non-Contact Voltage Detector RSCAL
- Fluke 376 FC Clamp Meter CAT IV Non-Contact Voltage Detector RSCAL
- Fluke 376 FC Clamp Meter CAT IV Non-Contact Voltage Detector UKAS

