Hager ADF Series Residual Current Circuit Breaker, 10 A, 1-Pole, 30 mA, Type C, 5 kA 230 V ac
- RS Stock No.:
- 602-227
- Mfr. Part No.:
- ADF810F
- Brand:
- Hager
Subtotal (1 unit)*
Kr. 4 043,93
(exc. VAT)
Kr. 5 054,91
(inc. VAT)
FREE delivery for online orders over 500,00 kr
Temporarily out of stock
- Shipping from 06 April 2026
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
|---|---|
| 1 + | Kr. 4 043,93 |
*price indicative
- RS Stock No.:
- 602-227
- Mfr. Part No.:
- ADF810F
- Brand:
- Hager
Specifications
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Hager | |
| Product Type | Residual Current Circuit Breaker | |
| Current Rating | 10 A | |
| Number of Poles | 1 | |
| Series | ADF | |
| Trip Sensitivity | 30mA | |
| Tripping Characteristics | Type C | |
| Mount Type | DIN Rail | |
| Standards/Approvals | IEC 60664, IEC 60947-2, IEC 60947-1, IEC 60898-1 | |
| Terminal Type | Screw Connection | |
| Depth | 68mm | |
| Width | 35 mm | |
| Height | 83mm | |
| Breaking Capacity | 5kA | |
| Earth Leakage Protection Type | F | |
| Rated AC Voltage | 230 V ac | |
| Select all | ||
|---|---|---|
Brand Hager | ||
Product Type Residual Current Circuit Breaker | ||
Current Rating 10 A | ||
Number of Poles 1 | ||
Series ADF | ||
Trip Sensitivity 30mA | ||
Tripping Characteristics Type C | ||
Mount Type DIN Rail | ||
Standards/Approvals IEC 60664, IEC 60947-2, IEC 60947-1, IEC 60898-1 | ||
Terminal Type Screw Connection | ||
Depth 68mm | ||
Width 35 mm | ||
Height 83mm | ||
Breaking Capacity 5kA | ||
Earth Leakage Protection Type F | ||
Rated AC Voltage 230 V ac | ||
- COO (Country of Origin):
- FR
The Hager Residual Current Circuit Breaker provides reliable protection against overcurrents and earth leakage. It is designed to detect alternating fault currents, ensuring the safety of both people and property. This device also helps maintain compliance with current electrical standards. It operates effectively within a wide serving temperature range.
Screw terminal connections
RoHS compliant
Related links
- Hager ADF Series Residual Current Circuit Breaker 1-Pole Type C, 5 kA 230 V ac
- Hager ADF Series Residual Current Circuit Breaker 1-Pole Type C, 3 kA 230 V ac
- Hager ADF Series Residual Current Circuit Breaker 1-Pole Type C, 4.5 kA 230 V ac
- Hager ADF Series Residual Current Circuit Breaker 1-Pole Type C, 6 kA 230 V ac
- Hager ADF Series Residual Current Circuit Breaker 1-Pole Type C, 3 kA 230 V ac
- Hager ADF Series Residual Current Circuit Breaker 1-Pole Type C, 4.5 kA 230 V ac
- Hager ADF Series Residual Current Circuit Breaker 1-Pole Type C, 6 kA 230 V ac
- Hager CDF Series Residual Current Circuit Breaker 2-Pole Type F, 1.5 kA 230 V ac