Schneider Electric Multi 9 Series Residual Current Circuit Breaker, 40 A, 2-Pole, 26 mA, Type A, 10 kA 415 V ac
- RS Stock No.:
- 211-2463
- Mfr. Part No.:
- M9R41240
- Brand:
- Schneider Electric
Subtotal (1 unit)*
Kr. 2 730,19
(exc. VAT)
Kr. 3 412,74
(inc. VAT)
FREE delivery for online orders over 500,00 kr
Stocked by manufacturer
- Ready to ship from 18 May 2026
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
|---|---|
| 1 + | Kr. 2 730,19 |
*price indicative
- RS Stock No.:
- 211-2463
- Mfr. Part No.:
- M9R41240
- Brand:
- Schneider Electric
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Schneider Electric | |
| Product Type | Residual Current Circuit Breaker | |
| Current Rating | 40 A | |
| Number of Poles | 2 | |
| Series | Multi 9 | |
| Range | Multi9 | |
| Trip Sensitivity | 26mA | |
| Tripping Characteristics | Type A | |
| Mount Type | DIN Rail | |
| Standards/Approvals | RoHS, REACH | |
| Terminal Type | Screw | |
| Depth | 60mm | |
| Width | 36 mm | |
| Height | 81mm | |
| Breaking Capacity | 10kA | |
| Earth Leakage Protection Type | Type A | |
| Rated AC Voltage | 415 V ac | |
| Tripping Mechanism | Electromagnetic | |
| Reset Actuator Type | Toggle Switch | |
| Break Time | Instantaneous | |
| Select all | ||
|---|---|---|
Brand Schneider Electric | ||
Product Type Residual Current Circuit Breaker | ||
Current Rating 40 A | ||
Number of Poles 2 | ||
Series Multi 9 | ||
Range Multi9 | ||
Trip Sensitivity 26mA | ||
Tripping Characteristics Type A | ||
Mount Type DIN Rail | ||
Standards/Approvals RoHS, REACH | ||
Terminal Type Screw | ||
Depth 60mm | ||
Width 36 mm | ||
Height 81mm | ||
Breaking Capacity 10kA | ||
Earth Leakage Protection Type Type A | ||
Rated AC Voltage 415 V ac | ||
Tripping Mechanism Electromagnetic | ||
Reset Actuator Type Toggle Switch | ||
Break Time Instantaneous | ||
- COO (Country of Origin):
- ES
The Schneider Electric Multi 9 GFP series is a Residual current circuit breaker (RCCB) with a Type A-SI Earth-leakage protection class. They are used for control and disconnection of electric circuits, protection of people against electric shock by direct and indirect contacts, protection of installations against insulation faults, enhanced continuity of supply, during a series of close lightning strokes.
Enhanced earth leakage protection
Protection of installations against insulation faults
Related links
- Schneider Electric Multi 9 Series Residual Current Circuit Breaker 2-Pole Type A, 10 kA 415 V ac
- Schneider Electric Multi 9 Series Residual Current Circuit Breaker 2-Pole Type A, 10 kA 415 V ac
- Schneider Electric Multi 9 Series Residual Current Circuit Breaker 4-Pole Type A, 10 kA 415 V ac
- Schneider Electric Multi 9 Series Residual Current Circuit Breaker 2-Pole Type A, 10 kA 415 V ac
- Schneider Electric Multi 9 Series Residual Current Circuit Breaker 4-Pole Type A, 10 kA 415 V ac
- Schneider Electric Multi 9 Series Residual Current Device 3-Pole Type A 415 V ac
- Schneider Electric Multi 9 Series Residual Current Device 3-Pole Type AC 415 V ac
- Schneider Electric Multi9 Series Residual Current Circuit Breaker 2-Pole Type A-SI, 1500 A
