Siemens SENTRON Series Residual Current Circuit Breaker, 40 A, 4-Pole, 300 mA, Type A, 10 kA 400 V ac
- RS Stock No.:
- 211-9697
- Distrelec Article No.:
- 301-37-613
- Mfr. Part No.:
- 5SV3644-6KK01
- Brand:
- Siemens
Subtotal (1 unit)*
Kr. 2 253,11
(exc. VAT)
Kr. 2 816,39
(inc. VAT)
Stock information currently inaccessible - Please check back later
Units | Per unit |
|---|---|
| 1 + | Kr. 2 253,11 |
*price indicative
- RS Stock No.:
- 211-9697
- Distrelec Article No.:
- 301-37-613
- Mfr. Part No.:
- 5SV3644-6KK01
- Brand:
- Siemens
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Siemens | |
| Product Type | Residual Current Circuit Breaker | |
| Current Rating | 40 A | |
| Number of Poles | 4 | |
| Series | SENTRON | |
| Range | SENTRON | |
| Trip Sensitivity | 300mA | |
| Mount Type | DIN Rail | |
| Tripping Characteristics | Type A | |
| Standards/Approvals | CE, UKCA, EAC, VDE | |
| Terminal Type | Screw | |
| Height | 90mm | |
| Depth | 70mm | |
| Width | 72 mm | |
| Breaking Capacity | 10kA | |
| Rated AC Voltage | 400 V ac | |
| Reset Actuator Type | Toggle Switch | |
| Tripping Mechanism | Electromagnetic | |
| Break Time | Short | |
| Earth Leakage Protection Type | Type A | |
| Select all | ||
|---|---|---|
Brand Siemens | ||
Product Type Residual Current Circuit Breaker | ||
Current Rating 40 A | ||
Number of Poles 4 | ||
Series SENTRON | ||
Range SENTRON | ||
Trip Sensitivity 300mA | ||
Mount Type DIN Rail | ||
Tripping Characteristics Type A | ||
Standards/Approvals CE, UKCA, EAC, VDE | ||
Terminal Type Screw | ||
Height 90mm | ||
Depth 70mm | ||
Width 72 mm | ||
Breaking Capacity 10kA | ||
Rated AC Voltage 400 V ac | ||
Reset Actuator Type Toggle Switch | ||
Tripping Mechanism Electromagnetic | ||
Break Time Short | ||
Earth Leakage Protection Type Type A | ||
- COO (Country of Origin):
- DE
The Siemens Residual current operated circuit breaker has 4-pole and type A. Used for short-time delayed. Operating current is 40 A and trippening residual current 300 mA. Supply voltage is 400 V. RCD is the residual current device for touch protection RCCBs, type A trip with both sinusoidal alternating currents (type AC) and pulsating DC residual currents. They are used mainly with single-phase consumers with electrical components in the supply unit, e.g. in residential and functional structures. Siemens offers a comprehensive portfolio of protection, switching, measuring and monitoring devices, distribution systems as well as switches and sockets for safe and efficient electrical infrastructure in buildings and industry.
Protection class IP IP20 if the distribution board is installed, with connected conductors
Silicon- free
Related links
- Siemens SENTRON Series Residual Current Circuit Breaker 4-Pole Type F, 10 kA 400 V ac
- Siemens SENTRON Series Residual Current Circuit Breaker 4-Pole Type A, 10 kA 400 V ac
- Siemens SENTRON Series Residual Current Circuit Breaker 4-Pole Type A, 0.8 kA 400 V ac
- Siemens SENTRON Series Residual Current Circuit Breaker 4-Pole Type B, 10 kA 400 V ac
- Siemens SENTRON Series Residual Current Circuit Breaker 4-Pole Type A, 10 kA 400 V ac
- Siemens SENTRON Series Residual Current Circuit Breaker 4-Pole Type A, 10 kA 400 V ac
- Siemens SENTRON Series Residual Current Circuit Breaker 4-Pole Type A, 10 kA 400 V ac
- Siemens SENTRON Series Residual Current Circuit Breaker 2-Pole Type A, 10 kA 400 V ac