Siemens SENTRON Series Residual Current Circuit Breaker, 63 A, 4-Pole, 300 mA, Type A, 10 kA 400 V ac
- RS Stock No.:
- 211-9701
- Mfr. Part No.:
- 5SV3646-4KK14
- Brand:
- Siemens
Subtotal (1 unit)*
Kr. 14 998,50
(exc. VAT)
Kr. 18 748,12
(inc. VAT)
Stock information currently inaccessible - Please check back later
Units | Per unit |
|---|---|
| 1 + | Kr. 14 998,50 |
*price indicative
- RS Stock No.:
- 211-9701
- Mfr. Part No.:
- 5SV3646-4KK14
- Brand:
- Siemens
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Siemens | |
| Product Type | Residual Current Circuit Breaker | |
| Current Rating | 63 A | |
| Number of Poles | 4 | |
| Series | SENTRON | |
| Range | SENTRON | |
| Trip Sensitivity | 300mA | |
| Tripping Characteristics | Type A | |
| Mount Type | DIN Rail | |
| Standards/Approvals | EAC, UKCA, CE, VDE | |
| Terminal Type | Screw | |
| Depth | 70mm | |
| Width | 72 mm | |
| Height | 90mm | |
| Breaking Capacity | 10kA | |
| Reset Actuator Type | Toggle Switch | |
| Tripping Mechanism | Electromagnetic | |
| Rated AC Voltage | 400 V ac | |
| Break Time | Instantaneous | |
| Earth Leakage Protection Type | Type A | |
| Select all | ||
|---|---|---|
Brand Siemens | ||
Product Type Residual Current Circuit Breaker | ||
Current Rating 63 A | ||
Number of Poles 4 | ||
Series SENTRON | ||
Range SENTRON | ||
Trip Sensitivity 300mA | ||
Tripping Characteristics Type A | ||
Mount Type DIN Rail | ||
Standards/Approvals EAC, UKCA, CE, VDE | ||
Terminal Type Screw | ||
Depth 70mm | ||
Width 72 mm | ||
Height 90mm | ||
Breaking Capacity 10kA | ||
Reset Actuator Type Toggle Switch | ||
Tripping Mechanism Electromagnetic | ||
Rated AC Voltage 400 V ac | ||
Break Time Instantaneous | ||
Earth Leakage Protection Type Type A | ||
- COO (Country of Origin):
- DE
The Siemens Residual current operated circuit breaker has a 4-pole and Type B+. Used for short-time delayed. Operating current is 63 A and residual current 300 mA. Supply voltage is 400 V. The RCD is the residual current device for touch protection. They have an additional converter to detect DC residual currents and are suitable for use in a three-phase system upstream of input current circuits with rectifiers. Siemens offers a comprehensive portfolio of protection, switching, measuring and monitoring devices, distribution systems as well as switches and sockets for safe and efficient electrical infrastructure in buildings and industry.
Protection class IP IP20 if the distribution board is installed, with connected conductors
Silicon- free
Related links
- Siemens SENTRON Series Residual Current Circuit Breaker 4-Pole Type A, 10 kA 400 V ac
- Siemens SENTRON Series Residual Current Circuit Breaker 4-Pole Type A, 10 kA 400 V ac
- Siemens SENTRON Series Residual Current Circuit Breaker 4-Pole Type A, 10 kA 400 V ac
- Siemens SENTRON Series Residual Current Circuit Breaker 4-Pole Type A, 0.8 kA 400 V ac
- Siemens SENTRON Series Residual Current Circuit Breaker 4-Pole Type B, 10 kA 400 V ac
- Siemens SENTRON Series Residual Current Circuit Breaker 4-Pole Type F, 10 kA 400 V ac
- Siemens SENTRON Series Residual Current Circuit Breaker 4-Pole Type A, 10 kA 400 V ac
- Siemens SENTRON Series Residual Current Circuit Breaker 4-Pole Type A, 10 kA 400 V ac