Better World
Schneider Electric Acti9 Series Residual Current Device, 32 A, 1-Pole, 300 mA, Type C, 6000 A 230 V ac
- RS Stock No.:
- 790-7315
- Mfr. Part No.:
- A9D42632
- Brand:
- Schneider Electric
Subtotal (1 unit)*
Kr. 2 172,23
(exc. VAT)
Kr. 2 715,29
(inc. VAT)
FREE delivery for online orders over 500,00 kr
Temporarily out of stock
- 3 unit(s) shipping from 01 May 2026
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
|---|---|
| 1 + | Kr. 2 172,23 |
*price indicative
Better World
Our Better World range features products that make it easy for you to make a greener product choice you can trust. Click here to find out more.
- RS Stock No.:
- 790-7315
- Mfr. Part No.:
- A9D42632
- Brand:
- Schneider Electric
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Schneider Electric | |
| Product Type | Residual Current Device | |
| Current Rating | 32 A | |
| Number of Poles | 1 | |
| Series | Acti9 | |
| Range | Acti9 | |
| Trip Sensitivity | 300mA | |
| Tripping Characteristics | Type C | |
| Mount Type | DIN Rail | |
| Standards/Approvals | EN/IEC 61009-2-1, RoHS, REACH | |
| Terminal Type | Single Terminal | |
| Depth | 73mm | |
| Height | 85mm | |
| Width | 36 mm | |
| Breaking Capacity | 6000A | |
| Better World Product | Yes | |
| Reset Actuator Type | Toggle Switch | |
| Earth Leakage Protection Type | Type A | |
| Application | Residual Current Device | |
| Rated AC Voltage | 230 V ac | |
| Tripping Mechanism | Thermal Magnetic | |
| Break Time | Instantaneous | |
| Select all | ||
|---|---|---|
Brand Schneider Electric | ||
Product Type Residual Current Device | ||
Current Rating 32 A | ||
Number of Poles 1 | ||
Series Acti9 | ||
Range Acti9 | ||
Trip Sensitivity 300mA | ||
Tripping Characteristics Type C | ||
Mount Type DIN Rail | ||
Standards/Approvals EN/IEC 61009-2-1, RoHS, REACH | ||
Terminal Type Single Terminal | ||
Depth 73mm | ||
Height 85mm | ||
Width 36 mm | ||
Breaking Capacity 6000A | ||
Better World Product Yes | ||
Reset Actuator Type Toggle Switch | ||
Earth Leakage Protection Type Type A | ||
Application Residual Current Device | ||
Rated AC Voltage 230 V ac | ||
Tripping Mechanism Thermal Magnetic | ||
Break Time Instantaneous | ||
Schneider Electric iDPN Series Residual Current Circuit Breaker, 32A Current Rating, 300mA Trip Sensitivity - A9D42632
This residual current circuit breaker is designed to protect electrical systems from earth fault currents. It features a compact DIN rail mount and dimensions of 36 x 85 x 73 mm. The device provides earth leakage protection with a sensitivity of 300mA, ensuring quick disconnection from faults.
Features & Benefits
• Thermal-magnetic design ensures reliable tripping under overload conditions
• Instantaneous break time enhances user safety by providing immediate disconnection
• Type C characteristics protect against higher inrush currents in motors
• 6000A breaking capacity accommodates standard electrical installations
• Suitable for isolation, ensuring safe maintenance procedures
• Integrated earth-leakage protection prevents electrical hazards
Applications
• Ideal for residential and commercial distribution boards
• Utilised in electrical installations requiring robust earth fault protection
• Suitable for circuits with motors and transformers for added safety
• Frequently used in demanding immediate fault response
What is the significance of having a 300 mA sensitivity?
A sensitivity of 300mA is specifically designed to detect and trip during earth leakage occurrences that could pose a risk of electric shock, making it suitable for general use in various installations.
How does the thermal-magnetic tripping mechanism function?
The thermal-magnetic tripping mechanism operates by using both thermal and electromagnetic forces to respond to overload and short circuit conditions, ensuring reliable disconnection in a timely manner.
Can this device be easily installed in existing systems?
Yes, it is designed for DIN rail mounting, allowing for easy integration into existing distribution boards while adhering to standard installation practices.
Related links
- Schneider Electric Acti9 Series Residual Current Device 1-Pole Type B, 6000 A 230 V ac
- Schneider Electric Acti9 Series Residual Current Device 1-Pole Type C, 6000 A 230 V ac
- Schneider Electric Acti9 Series Residual Current Device 2-Pole Type AC, 125 V dc 500 V ac
- Schneider Electric Acti9 Series Residual Current Device 4-Pole Type AC, 125 V dc 500 V ac
- Schneider Electric Acti9 Series Residual Current Device 2-Pole Type A, 125 V dc 500 V ac
- Schneider Electric iDPN Series Residual Current Device 1-Pole Type C, 6000 A 230 V ac
- Schneider Electric Acti9 iDT40 Series Residual Current Device 3-Pole Type AC, 1500 A
- Schneider Electric Acti9 iDT40 Series Residual Current Device 1-Pole Type A-SI, 40 A