RS PRO TYA-201 Series Signal Conditioner, Current Input, Relay Output, 230 V ac, 115 V ac Supply
- RS Stock No.:
- 629-465
- Brand:
- RS PRO
Subtotal (1 unit)*
Kr. 2 986,81
(exc. VAT)
Kr. 3 733,51
(inc. VAT)
FREE delivery for online orders over 500,00 kr
In Stock
- 5 unit(s) ready to ship
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
|---|---|
| 1 + | Kr. 2 986,81 |
*price indicative
- RS Stock No.:
- 629-465
- Brand:
- RS PRO
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | RS PRO | |
| Product Type | Signal Conditioner | |
| Input Signal Type | Current | |
| Output Signal Type | Relay | |
| Input Range | 4 to 20 mA | |
| Output Range | 250 V ac, 220 V dc, 2 A | |
| Supply Voltage | 230 V ac, 115 V ac | |
| Hazardous Area Certification | No | |
| Mount Type | DIN Rail | |
| Maximum Operating Temperature | 45°C | |
| Terminal Type | Screw | |
| Minimum Operating Temperature | 0°C | |
| Signal Conditioner Type | Amplifier | |
| Standards/Approvals | No | |
| Series | TYA-201 | |
| Number of Channels | 1 | |
| Select all | ||
|---|---|---|
Brand RS PRO | ||
Product Type Signal Conditioner | ||
Input Signal Type Current | ||
Output Signal Type Relay | ||
Input Range 4 to 20 mA | ||
Output Range 250 V ac, 220 V dc, 2 A | ||
Supply Voltage 230 V ac, 115 V ac | ||
Hazardous Area Certification No | ||
Mount Type DIN Rail | ||
Maximum Operating Temperature 45°C | ||
Terminal Type Screw | ||
Minimum Operating Temperature 0°C | ||
Signal Conditioner Type Amplifier | ||
Standards/Approvals No | ||
Series TYA-201 | ||
Number of Channels 1 | ||
RoHS Status: Exempted
- COO (Country of Origin):
- GB
Signal Conditioning Units
RS Pro single or dual trip amplifiers with the facility to arrange each trip so that the alarm condition can be above (high trip) or below (low trip) the set point. The relay can be either energise/de-energise in the alarm condition (fail-safe) or de-energise/energise in the alarm condition (non-fail safe).
Dual supply voltage operation
Bi-colour LED status indication
Front panel adjustment of "Trip Levels"
Input and output stages powered from separate secondaries of the supply transformer to provide 3-port isolation
Dual supply voltage operation
LED indication of "power on"
Note
Trip settings are set via links on a PBC within the unit,Signal isolators/Converters; Four units which provide signal isolation via an opto-isolated hybrid circuit. The 0-10Vdc; 4-20mA units also convert process signals into a required standard transmission voltage or current signals
Related links
- RS PRO BD Series Signal Conditioner Current Output 115 V ac Supply
- RS PRO BD Series Signal Conditioner Relay Output, 115 V ac Supply
- RS PRO BD Series Signal Conditioner Relay Output, 230 V ac Supply
- RS PRO BD Series Signal Conditioner Current Output, 115 V ac Supply
- Weidmüller ACT20P Series Signal Conditioner Current Output ATEX
- Jumo TYA-200 Series Signal Conditioner Relay Output
- RS PRO 9100 Series Signal Conditioner Relay Output, 10/30 V dc Supply
- Eaton MTL Series Signal Conditioner Relay Output 40 V dc Supply Div 1 Group A,