PR Electronics 5300 Temperature Transmitter Linear Resistance, RTD, Thermocouple, Voltage Input, 8 → 30 V dc
- RS Stock No.:
- 827-5448
- Mfr. Part No.:
- 5335D
- Brand:
- PR Electronics
Subtotal (1 unit)*
Kr.5 185 61
(exc. VAT)
Kr.6 482 01
(inc. VAT)
FREE delivery for online orders over 500,00 kr
In Stock
- 55 unit(s) ready to ship
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
|---|---|
| 1 + | Kr. 5 185,61 |
*price indicative
- RS Stock No.:
- 827-5448
- Mfr. Part No.:
- 5335D
- Brand:
- PR Electronics
Specifications
Technical Reference
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | PR Electronics | |
| Input Type | Linear Resistance, RTD, Thermocouple, Voltage | |
| Supply Voltage | 8 → 30 V dc | |
| Diameter | 44 mm | |
| Minimum Temperature Input | -200°C | |
| Maximum Temperature Input | 850°C | |
| Minimum Operating Temperature | -40°C | |
| Maximum Operating Temperature | +85°C | |
| Series | 5300 | |
| Depth | 20.2mm | |
| Hazardous Area Certification | ATEX | |
| Select all | ||
|---|---|---|
Brand PR Electronics | ||
Input Type Linear Resistance, RTD, Thermocouple, Voltage | ||
Supply Voltage 8 → 30 V dc | ||
Diameter 44 mm | ||
Minimum Temperature Input -200°C | ||
Maximum Temperature Input 850°C | ||
Minimum Operating Temperature -40°C | ||
Maximum Operating Temperature +85°C | ||
Series 5300 | ||
Depth 20.2mm | ||
Hazardous Area Certification ATEX | ||
- COO (Country of Origin):
- DK
5300 Series - In-Head Temperature Transmitter
PR Electronics 5300 series single input temperature transmitter offers unrivalled performance In applications making heavy demands on accuracy to convert a wide array of input types to a 4 – 20 mA output signal. The 5300 series transmitters are quickly and easily programmable to the specific application. Configuration via a standard PC and user-friendly software, PReset, available as a free download. Parameters for input, output, sensor error detection and process calibration can be configured via PReset within a few minutes.
Features and Benefits
• For DIN form B sensor head mounting
• Sensor drift detection maintains measuring point reliability
• Flexible input capability, with choice of output modes
• Superior accuracy ensures true, reliable measurements
• Fast response time easily supports safety and cost-critical applications
• High immunity to conducted noise: tested against 10 Vrms in the range 15 Hz–100 MHz
• Continuous check of vital stored data for safety reasons
• Runtime meters provide a valuable history of the process temperature and the ambient temperature around the transmitter
• Very low temperature coefficient ensuring maximum accuracy across changing ambient conditions
• Sensor drift detection maintains measuring point reliability
• Flexible input capability, with choice of output modes
• Superior accuracy ensures true, reliable measurements
• Fast response time easily supports safety and cost-critical applications
• High immunity to conducted noise: tested against 10 Vrms in the range 15 Hz–100 MHz
• Continuous check of vital stored data for safety reasons
• Runtime meters provide a valuable history of the process temperature and the ambient temperature around the transmitter
• Very low temperature coefficient ensuring maximum accuracy across changing ambient conditions
Sensor Inputs
The PR 5335 programmable transmitter provides unrivalled input versatility. Virtually any thermocouple or 2, 3 & 4 RTD plus linear resistance up to 700 Ω and bipolar mV signals. Input sensor redundancy function maintains process availability and safety in the event of primary sensor failure. An alert via HART can be used to allow scheduling of maintenance on the faulty sensor.
What is HART?
The HART protocol is a low speed, digital communications scheme that is carried on a 4…20 mA current signal. Since 4…20 mA loops are commonly used in industry, the HART protocol is easy to implement, easy to use, and easy to troubleshoot.
Related links
- Red Lion IAMS Series Signal Conditioner Linear Resistance RTD Voltage Input,
- Rosemount 248 Temperature Transmitter Bipolar mV Potentiometer TC Input, 42.4 V dc
- Turck 1 Channel Galvanic Barrier RTD Voltage Input
- Red Lion IAMA Series Isolated Universal Converter Linear Resistance RTD
- Seneca Z109REG2-1 Series Universal Converter Linear Resistance Pulse Thermocouple,
- Phoenix Contact Signal Transducer Thermocouple Current Output
- Weidmuller ACT20X Series Signal Conditioner RTD Voltage Input 19.2 →
- GEORGIN BPX Series Signal Converter RTD Voltage Input ATEX