PAT Testers | Portable PAT Testers | RS
Login / Register to access your benefits
Recently searched

    PAT Testers

    PAT testers, or portable appliance testers, are specialised testing devices that are essential for checking electrical devices for faults in a wide range of working environments. PAT testing equipment will provide a pass or fail for the appliance you are testing immediately, so you know it's safe to use. By using the appropriate type of PAT tester, you can identify potential electrical risks, mitigate hazards, and meet regulatory requirements. By purchasing a reliable PAT tester, you can protect both employees and your business, and help maintain a reputation for upholding high safety standards. You can find more information in our guide to PAT testing equipment.

    Why do I need to use a PAT Tester?

    Portable appliance testers play a vital role in ensuring electrical safety and compliance. A lot of electrical safety issues can and are detected by visually examining the appliances, but some will only be found by PAT testing. By testing your portable devices by visual inspection and with a tester designed for the purpose, the risk of potential safety problems such as shock and appliance failure are reduced. PAT testers can be calibrated to ensure maximum safety, as they can deviate from the manufacturer's settings. RS offer a UKAS calibrated service as well as our very own calibrated approval (RSCAL) for pinpoint readings.

    How often do portable electrical appliances need to be tested?

    PAT testing is a key component of the Electricity at Work Regulations 1989, which requires employers or the self-employed to do anything that is 'reasonably practical' to protect people from harm. The regulation does not specify the frequency of the testing. In general, the frequency of PAT testing depends on factors including they type of appliance, the environment it is used in, and the level of risk associated with its usage.

    PAT Tester Types?

    Deciding on the right PAT testing machine for your needs, you should first think about what you will be testing. Different models offer testing on different equipment. Some PAT testers can be used for Class I and Class II appliances, power leads, extension leads and RCDs. Many models include one-touch testing to return a pass or fail result, which can increase the number of tests that can be done in one day. You must also consider what voltages you are testing when selecting the right PAT tester.

    Why choose RS for a PAT Tester?

    RS offers a great range of PAT Testing Equipment and PAT Testing Kits, from market-leading brands such as Fluke, Megger and Seaward. RS has technical advisers on hand to provide you information not only on the product, but our calibrated service. All of our products are available for next day delivery.

    86 Products showing for PAT Testers

    • RS Stock No. 823-0414
    • Mfr. Part No. 1003-068
    Each
    Kr. 10 165,65
    Megger
    -
    Pass/Fail PAT
    Class I, Class II
    Automatic, Manual
    -
    PAT150-DE
    CEE 7/4 Schuko
    Battery
    AA
    4 days
    -
    1.3kg
    78mm
    203mm
    +40°C
    230V ac
    • RS Stock No. 717-3650
    • Mfr. Part No. 347A911
    Each
    Kr. 4 110,85
    Seaward
    -
    Pass/Fail PAT
    Class I, Class II
    Automatic
    -
    PrimeTest 50 UK
    Type G - British 3-pin
    Battery
    AA
    -
    -
    800g
    55mm
    260mm
    -
    230V
    • RS Stock No. 712-5452
    • Mfr. Part No. EPAT2100
    Each
    Kr. 11 423,26
    Martindale
    Flash Test
    Dual Voltage PAT
    Class I, Class II
    Manual
    -
    EPAT2100
    Type G - British 3-pin
    Mains
    -
    -
    -
    4.6kg
    144mm
    330mm
    +35°C
    240V
    Each
    Kr. 7 574,14
    Martindale
    -
    Dual Voltage PAT
    Class I, Class II, Class IT
    Manual
    -
    EPAT1600
    Type G - British 3-pin
    Mains
    -
    -
    -
    4kg
    144mm
    330mm
    +35°C
    240V
    Each
    Kr. 18 199,24
    Seaward
    Download
    PAT Tester Kit
    -
    Automatic
    UKAS
    Apollo 500 Pro Bundle UK
    -
    Battery, Mains
    -
    -
    -
    1.5kg
    100mm
    230mm
    -
    253V ac
    Each
    Kr. 12 519,26
    Martindale
    Flash Test
    Dual Voltage PAT
    Class I, Class II
    Manual
    RSCAL
    EPAT2100
    Type G - British 3-pin
    Mains
    -
    -
    -
    4.6kg
    144mm
    330mm
    +35°C
    240V
    Each
    Kr. 31 191,15
    Megger
    Download,Flash Test
    Pass/Fail PAT
    Class I, Class II
    Automatic, Manual
    UKAS
    PAT450
    BS 4343, Type G - British 3-pin
    Mains
    -
    -
    320 x 255 x 180mm
    5kg
    180mm
    320mm
    +50°C
    230V
    • RS Stock No. 705-1822
    • Mfr. Part No. 1000-751
    Each
    Kr. 29 608,15
    Megger
    Download,Flash Test
    Pass/Fail PAT
    Class I, Class II
    Automatic, Manual
    -
    PAT450
    BS 4343
    Mains
    -
    -
    320 x 255 x 180mm
    5kg
    180mm
    320mm
    +50°C
    230V
    • RS Stock No. 188-2935
    • Mfr. Part No. HPAT600-2
    Each
    Kr. 4 143,75
    Martindale
    -
    Pass/Fail PAT
    Class I, Class II
    Automatic, Manual
    -
    HPAT600/2
    -
    Battery
    AA
    600 (Test)
    90 x 54 x 210mm
    700g
    210mm
    90mm
    +40°C
    1.2V
    Each
    Kr. 9 149,76
    Seaward
    Download
    Advanced PAT
    Class I
    Automatic
    RSCAL
    PrimeTest 250+ UK
    -
    Battery
    AA
    -
    -
    -
    -
    -
    -
    254V ac
    Each
    Kr. 9 157,14
    Martindale
    -
    Dual Voltage PAT
    Class I, Class II, Class IT
    Manual
    UKAS
    EPAT1600
    BS 4343, Type G - British 3-pin
    Mains
    -
    -
    -
    4kg
    144mm
    330mm
    +35°C
    240V
    Each
    Kr. 33 748,00
    Gossen Metrawatt
    Download,Flash Test
    Advanced PAT
    AC and DC Patient Leakage Current, Class I, Class II, Class IT, Contact Current, Continuity, Current, Differential Current Measurement, Direct Measurement, Earth, Earth Leakage Current, Equivalent Leakage Current Procedure, I
    Automatic, Manual
    DAkkS
    SECUTEST LEMONGREEN
    -
    Mains
    -
    -
    295 x 145 x 150mm
    2.5kg
    145mm
    295mm
    +40°C
    230V
    • RS Stock No. 797-6709
    • Mfr. Part No. FLUKE-6500-2 UK
    Each
    Kr. 25 520,40
    Fluke
    Download
    Pass/Fail PAT
    Class I, Class II
    Automatic, Manual
    RSCAL
    6500
    Type G - British 3-pin
    Mains
    -
    -
    -
    3kg
    100mm
    200mm
    +40°C
    230V
    • RS Stock No. 823-0410
    • Mfr. Part No. 1003-066
    Each
    Kr. 7 832,55
    Megger
    -
    Pass/Fail PAT
    Class I, Class II
    Automatic, Manual
    -
    PAT 120-DE
    CEE 7/4 Schuko
    Battery
    AA
    4 days
    203 x 148 x 78mm
    1.2kg
    78mm
    203mm
    +40°C
    230V ac
    • RS Stock No. 823-0417
    • Mfr. Part No. 1003-071
    Each
    Kr. 10 165,65
    Megger
    -
    Pass/Fail PAT
    Class I, Class II
    Automatic, Manual
    -
    1003-064
    BS 1363
    Battery
    AA
    4 days
    203 x 148 x 78mm
    1.3kg
    78mm
    203mm
    +40°C
    230V ac
    • RS Stock No. 705-1828
    • Mfr. Part No. 1000-748
    Each
    Kr. 25 219,70
    Megger
    Download,Flash Test
    Pass/Fail PAT
    Class I, Class II
    Automatic, Manual
    -
    PAT410
    Type G - British 3-pin
    Mains
    -
    -
    320 x 255 x 145mm
    2.7kg
    145mm
    320mm
    +50°C
    230V
    Each
    Kr. 28 204,40
    Megger
    Download,Flash Test
    Pass/Fail PAT
    Class I, Class II
    Automatic, Manual
    RSCAL
    PAT420
    BS 4343, Type G - British 3-pin
    Mains
    -
    -
    320 x 255 x 180mm
    4.4kg
    180mm
    320mm
    +50°C
    230V
    Each
    Kr. 21 367,68
    Fluke
    Download
    Pass/Fail PAT
    Class I, Class II
    Manual
    RSCAL
    6200-2
    -
    Mains
    -
    -
    200 x 275 x 114mm
    3kg
    114mm
    200mm
    +40°C
    240V
    Each
    Kr. 37 883,00
    Gossen Metrawatt
    -
    Medical Safety Tester
    Class I, Class II
    Automatic, Manual
    UKAS
    SECUTEST S2 N+10
    -
    Mains
    -
    -
    292 x 130 x 243mm
    4.5kg
    243mm
    292mm
    -
    230V
    • RS Stock No. 261-5444
    • Mfr. Part No. P01145831
    Each
    Kr. 64 658,88
    Chauvin Arnoux
    Download,Flash Test
    Machine and Electrical Switchboard Testers
    Class I, Class II
    Automatic, Manual
    -
    CA 6163
    Type F - Schuko plug
    Mains
    -
    -
    340 x 405 x 194mm
    15kg
    194mm
    340mm
    +45°C
    5350V
    Results per page