PAT Testers

A PAT tester or portable appliance tester, is an electronic device that is used to check electrical devices for faults in a wide range of working environments.


Features


The PAT testers are usually portable, have a digital display that returns a pass or fail output reading. More advanced models incorporate additional features such as inbuilt label printers, on board memory, connectivity options and barcode readers.


Why do I need to use a PAT tester?


A lot of electrical safety issues can and are detected by visually examining the appliances but some will only be found by PAT testing. By testing your portable devices by visual inspection and with a tester designed for the purpose, the risk of potential safety problems such as shock and appliance failure are reduced.


How often do portable electrical appliances need to be tested?


PAT is a key component of the Electricity at Work Regulations 1989, which requires employers or the self-employed to do anything that is ’reasonably practical’ to protect people from harm. The regulation does not specify the frequency of the testing. Therefore the testing should be carried out according to the environment and purpose of the equipment.


Types


Deciding on the right PAT tester for your needs you should firstly think about what you will be testing. Different models offer testing on different kinds of equipment.


Some PAT testers can be used for Class I and Class II appliances, power leads, extension leads and RCDs. Many models include one-touch testing to return a pass or fail result which can increase the number of tests that can be done in one day. You must also consider what voltages you are testing when selecting the right PAT tester.


...
Read more Read less

Filters

Viewing 41 - 60 of 93 products
Results per page
Description Price Tester Type Test Type Testing Method Calibrated Download Flash Test Power Source Battery Type Battery Life Dimensions Weight Height Length Maximum Operating Temperature
RS Stock No. 712-5452
Mfr. Part No.EPAT2100
BrandMartindale
kr 8 996,19
Each
Units
- Class I, Class II Manual - - Yes Mains - - - 4.6kg 144mm 330mm +35°C
RS Stock No. 823-0423
Mfr. Part No.1003-428
BrandMegger
kr 8 683,20
Each
Units
Pass/Fail PAT Class I, Class II Automatic, Manual - - - Battery AA 4 days - 1.3kg 78mm 203mm +40°C
RS Stock No. 797-6705
Mfr. Part No.FLUKE-6200-2 UK
BrandFluke
kr 13 911,00
Each
Units
Pass/Fail PAT Class I, Class II Manual UKAS - - Mains - - - 3kg 100mm 200mm +40°C
RS Stock No. 706-6921
Mfr. Part No.392A910
BrandSeaward
kr 5 313,94
Each
Units
Pass/Fail PAT Class I, Class II Automatic, Manual - - - Battery, Mains - - - - - - -
RS Stock No. 712-8846
Mfr. Part No.283A937
BrandSeaward
kr 15 397,88
Each
Units
Advanced PAT Class I, Class II, Class IT Automatic, Manual UKAS Yes Yes Mains - - - 9.5kg 160mm 400mm -
RS Stock No. 705-7214
Mfr. Part No.PAT450-UK
BrandMegger
kr 22 568,80
Each
Units
Pass/Fail PAT Class I, Class II Automatic, Manual RSCAL Yes Yes Mains - - - 5kg 180mm 320mm +50°C
RS Stock No. 712-5456
Mfr. Part No.RSMPATPLUS
BrandMartindale
kr 10 006,80
Each
Units
Computerised PAT Class I, Class II Automatic, Manual - Yes Yes Mains - - - 4.8kg 144mm 330mm -
RS Stock No. 711-8987
Mfr. Part No.RSMPATPLUS
BrandMartindale
kr 11 158,80
Each
Units
Computerised PAT Class I, Class II Automatic, Manual UKAS Yes Yes Mains - - - 4.8kg 144mm 330mm -
RS Stock No. 175-7076
Mfr. Part No.380930
BrandSeaward
kr 9 518,63
Each
Units
PAT Tester - Automatic UKAS Yes - Battery, Mains Rechargeable Battery - - 1.5kg 100mm 230mm -
RS Stock No. 705-7205
Mfr. Part No.PAT410-UK
BrandMegger
kr 18 421,60
Each
Units
Pass/Fail PAT Class I, Class II Automatic, Manual RSCAL Yes Yes Mains - - - 2.7kg 145mm 320mm +50°C
RS Stock No. 188-2934
Mfr. Part No.HPAT500/2
BrandMartindale
kr 3 250,55
Each
Units
- Class I, Class II Automatic - - - Battery AA 600 (Test) - 700g 210mm 90mm +40°C
RS Stock No. 716-1020
Mfr. Part No.344A911
BrandSeaward
kr 5 128,32
Each
Units
Pass/Fail PAT Class I, Class II Automatic UKAS - - Battery AA - - 800g 55mm 260mm -
RS Stock No. 386-4548
Mfr. Part No.RSLTDV
BrandMartindale
kr 1 227,16
Each
Units
- - - - - - Mains - - - - 51mm 141mm +35°C
RS Stock No. 175-7083
Mfr. Part No.380A9893
BrandSeaward
kr 29 683,48
Each
Units
Pass/Fail PAT - Automatic RSCAL Yes Yes Battery, Mains Rechargeable Battery - - 1.5kg 100mm 230mm -
RS Stock No. 705-6280
Mfr. Part No.1000-752
BrandMegger
kr 20 217,60
Each
Units
Pass/Fail PAT Class I, Class II Automatic, Manual - Yes Yes Mains - - - 4.4kg 180mm 320mm +50°C
RS Stock No. 175-7085
Mfr. Part No.380A9896
BrandSeaward
kr 22 475,75
Each
Units
Pass/Fail PAT - Automatic RSCAL Yes - Battery, Mains Rechargeable Battery - - 1.5kg 100mm 230mm -
RS Stock No. 711-9035
Mfr. Part No.PAT320-UK
BrandMegger
kr 14 695,20
Each
Units
Pass/Fail PAT Class I, Class II Automatic, Manual UKAS - - Mains - - - 4.5kg 175mm 320mm +50°C
RS Stock No. 712-5440
Mfr. Part No.EPAT1600
BrandMartindale
kr 6 280,19
Each
Units
- Class I, Class II, Class IT Manual - - - Mains - - - 4kg 144mm 330mm +35°C
RS Stock No. 823-0414
Mfr. Part No.1003-068
BrandMegger
kr 8 100,00
Each
Units
Pass/Fail PAT Class I, Class II Automatic, Manual - - - Battery AA 4 days - 1.3kg 78mm 203mm +40°C
RS Stock No. 712-8849
Mfr. Part No.283A937
BrandSeaward
kr 15 041,88
Each
Units
Advanced PAT Class I, Class II, Class IT Automatic, Manual RSCAL Yes Yes Mains - - - 9.5kg 160mm 400mm -