Fluke 355 True-RMS, 2000A Clamp Meter
Confidently take reliable readings with the True-rms, Fluke 355 digital clamp meter; the tool of choice for high current clamp-on amp meter measurement up to 2000 A. The extra-wide jaw easily clamps around large conductors, typically found in high-current applications. The extra rugged design and CAT IV 600 V, CAT III 1000 V ratings add an extra element of user protection when taking high-powered measurements.
Accurate peak measurements can be taken using the in-rush current mode, ideal for motors and inductive loads. The 355 also measures voltage and resistance, making this an ideal clamp meter for utilities, electrical contractors and industrial service technicians.
Features:
4000 count backlit display
True-RMS AC + DC current & voltage measurement
True RMS crest factor = 2.4
Motor inrush current measurement
Min/Max/Average recording mode
Frequency Measurement
Voltage AC/DC
Resistance measurement
Continuity measurement with beeper
58mm dia conductor jaw capacity
Safety to EN61010 CAT IV 600 V, CAT III 1000 V
True-RMS AC + DC current & voltage measurement
True RMS crest factor = 2.4
Motor inrush current measurement
Min/Max/Average recording mode
Frequency Measurement
Voltage AC/DC
Resistance measurement
Continuity measurement with beeper
58mm dia conductor jaw capacity
Safety to EN61010 CAT IV 600 V, CAT III 1000 V
Supplied with
C43 soft case, 6 AA alkaline batteries, TL224 1.5m silicone test leads, TP2 slim reach probes (2 mm), AC285 crocodile clips and users manual
Buy a Fluke, Get one Free is back!!
Between March 1st, 2024 and August 31st, 2024, the customer spends €150 or more on a qualifying Fluke product (Fluke Industrial, Fluke Calibration, Fluke Networks, or Beha-Amprobe).
Customer claims their tool online at: www.fluke.com/en/freefluke
A proof of purchase in the form of a receipt or invoice is required.
Note: Offer not available in South Africa
Between March 1st, 2024 and August 31st, 2024, the customer spends €150 or more on a qualifying Fluke product (Fluke Industrial, Fluke Calibration, Fluke Networks, or Beha-Amprobe).
Customer claims their tool online at: www.fluke.com/en/freefluke
A proof of purchase in the form of a receipt or invoice is required.
Note: Offer not available in South Africa
Specifications
Attribute | Value |
---|---|
Absolute Maximum AC Current Measurement | 2000A ac |
Absolute Maximum DC Current Measurement | 2000A dc |
Absolute Maximum AC Voltage Measurement | 600V ac |
Absolute Maximum DC Voltage Measurement | 1000V dc |
Absolute Maximum Resistance Measurement | 400kΩ |
Model Number | 355 |
AC Current Measurement Resolution | 10mA |
DC Current Measurement Resolution | 10mA |
Best DC Current Accuracy | ±(1.5% rdg +5 Digits) |
Clamp Meter Type | AC/DC Clamp Meter |
Best AC Current Accuracy | ±(1.5% rdg +5 Digits) |
Best AC Voltage Accuracy | ±(1% rdg +5 Digits) |
True RMS | Yes |
Best DC Voltage Accuracy | ±(1% rdg +5 Digits) |
Functions Measured | AC Current, AC Voltage, Continuity, DC Current, DC Voltage, Frequency, Resistance |
Jaw Capacity Busbars | 58mm |
Minimum Operating Temperature | 0°C |
Height | 52mm |
Display Type | LCD |
Best Resistance Measurement Accuracy | ±1.5% +5 Digits |
Safety Category | CAT III 1000 V, CAT IV 600V |
Maximum Conductor Size | 58mm |
AC Voltage Measurement Range | 4 V, 40 V, 400 V, 600 V |
DC Voltage Measurement Resolution | 1mV |
Resistance Measurement Resolution | 100mΩ |
Length | 300mm |
Power Source | Battery |
Dimensions | 300 x 98 x 52mm |
DC Current Measurement Range | 40/400/2000/1400 A |
Width | 98mm |
Battery Type | AA |
Safety Category Voltage | 600 V, 1000V |
Safety Category Level | CAT IV, CAT III |
Weight | 814g |
Battery Life | 100 h |
AC Current Measurement Range | 40A, 400A, 2000A, 1400 A |
Maximum Operating Temperature | +50°C |
AC Voltage Measurement Resolution | 1mV |