Fluke 325 Clamp Meter, 400 A 400 A 600 V dc 600 V ac CAT IV, CAT III Non-Contact Voltage Detector
- RS Stock No.:
- 765-3660
- Distrelec Article No.:
- 176-41-233
- Mfr. Part No.:
- FLUKE 325
- Brand:
- Fluke
Subtotal (1 unit)*
Kr. 2 848,32
(exc. VAT)
Kr. 3 560,40
(inc. VAT)
FREE delivery for online orders over 500,00 kr
- 8 unit(s) ready to ship from another location
- Plus 227 unit(s) shipping from 26 March 2026
- Plus 56 unit(s) shipping from 16 April 2026
Units | Per unit |
|---|---|
| 1 + | Kr. 2 848,32 |
*price indicative
- RS Stock No.:
- 765-3660
- Distrelec Article No.:
- 176-41-233
- Mfr. Part No.:
- FLUKE 325
- Brand:
- Fluke
Select all | Attribute | Value |
|---|---|---|
| Brand | Fluke | |
| Product Type | Clamp Meter | |
| Resistance Resolution | 100mΩ | |
| Maximum DC Current Measurement | 400A | |
| Maximum AC Voltage Measurement | 600V ac | |
| Maximum DC Voltage Measurement | 600V dc | |
| Maximum Resistance Measurement | 40kΩ | |
| Model Number | 325 | |
| DC Current Resolution | 10mA | |
| DC Current Accuracy | ±2 % rdg + 5 Digits | |
| Temperature Resolution | 0.1°C | |
| AC Current Accuracy | ±2 % rdg + 5 Digits | |
| DC Voltage Resolution | 100 mV dc | |
| Resistance Measurement Accuracy | ±1.0 % rdg + 5 Digits | |
| AC Current Resolution | 10mA | |
| Minimum Operating Temperature | -10°C | |
| AC Voltage Accuracy | ±1.5 % rdg + 5 Digits | |
| AC Voltage Resolution | 100mV ac | |
| DC Voltage Accuracy | ±1 % rdg + 5 Digits | |
| Clamp Meter Type | AC/DC Clamp Meter | |
| Maximum Jaw Opening | 30 mm | |
| Maximum Operating Temperature | 50°C | |
| Width | 75 mm | |
| Height | 34mm | |
| Length | 207mm | |
| Weight | 283g | |
| Standards/Approvals | RoHS | |
| True RMS | Yes | |
| Functions Measured | Capacitance, Frequency, AC Voltage, Temperature, DC Voltage, Continuity, DC Current, AC Current, Resistance | |
| Battery Type | AAA | |
| Display Type | LCD | |
| Safety Category Voltage | 500V | |
| Power Source | Battery | |
| Safety Category Level | CAT IV, CAT III | |
| Non-Contact Voltage Detector | Yes | |
| Maximum Temperature Measurement | 400°C | |
| Maximum AC Current Measurement | 400A | |
| Maximum Conductor Size | 30 mm | |
| Select all | ||
|---|---|---|
Brand Fluke | ||
Product Type Clamp Meter | ||
Resistance Resolution 100mΩ | ||
Maximum DC Current Measurement 400A | ||
Maximum AC Voltage Measurement 600V ac | ||
Maximum DC Voltage Measurement 600V dc | ||
Maximum Resistance Measurement 40kΩ | ||
Model Number 325 | ||
DC Current Resolution 10mA | ||
DC Current Accuracy ±2 % rdg + 5 Digits | ||
Temperature Resolution 0.1°C | ||
AC Current Accuracy ±2 % rdg + 5 Digits | ||
DC Voltage Resolution 100 mV dc | ||
Resistance Measurement Accuracy ±1.0 % rdg + 5 Digits | ||
AC Current Resolution 10mA | ||
Minimum Operating Temperature -10°C | ||
AC Voltage Accuracy ±1.5 % rdg + 5 Digits | ||
AC Voltage Resolution 100mV ac | ||
DC Voltage Accuracy ±1 % rdg + 5 Digits | ||
Clamp Meter Type AC/DC Clamp Meter | ||
Maximum Jaw Opening 30 mm | ||
Maximum Operating Temperature 50°C | ||
Width 75 mm | ||
Height 34mm | ||
Length 207mm | ||
Weight 283g | ||
Standards/Approvals RoHS | ||
True RMS Yes | ||
Functions Measured Capacitance, Frequency, AC Voltage, Temperature, DC Voltage, Continuity, DC Current, AC Current, Resistance | ||
Battery Type AAA | ||
Display Type LCD | ||
Safety Category Voltage 500V | ||
Power Source Battery | ||
Safety Category Level CAT IV, CAT III | ||
Non-Contact Voltage Detector Yes | ||
Maximum Temperature Measurement 400°C | ||
Maximum AC Current Measurement 400A | ||
Maximum Conductor Size 30 mm | ||
RoHS Status: Exempted
- COO (Country of Origin):
- CN
Fluke Clamp Meter, 400A Maximum AC Current Measurement, 600V Maximum AC Voltage Measurement - FLUKE 325
Features & Benefits
• Measures AC/DC voltages to 600V for broad electrical systems
• 400A jaw capacity with 30mm opening for large conductor testing
• 10mA resolution on current for fine detection of small changes
• Temperature measurement with supplied K-type probe for contact work
• Resistance to 40kΩ and continuity function for circuit verification
Applications
• Ideal for maintenance of automation and motor control panels
• Used for HVAC servicing with temperature and frequency checks
• Can be used for on-site electrical installation verification
• Used with test leads for voltage diagnostics on machinery
What power source does it use and how is it supplied?
How does the non-contact voltage detector aid on-site safety checks?
What frequency range can be measured and why is that useful?
Which safety categories apply for use in different locations?
Supplied with
TL75 Test Leads
Type K Thermocouple
Two AAA Batteries (Installed)
Soft Case
Related links
- Fluke 325 Clamp Meter CAT III Non-Contact Voltage Detector
- Fluke 324 Clamp Meter CAT III Non-Contact Voltage Detector
- Fluke 323 Clamp Meter CAT III Non-Contact Voltage Detector
- Fluke 355 Clamp Meter CAT III Non-Contact Voltage Detector
- Fluke 355 Clamp Meter CAT III Non-Contact Voltage Detector
- Fluke 323 Clamp Meter CAT III Non-Contact Voltage Detector
- Fluke 324 Clamp Meter CAT III Non-Contact Voltage Detector
- Fluke 381 Clamp Meter CAT III Non-Contact Voltage Detector