SICK FLEXIL Series Input/Output Module, 1 Inputs, 16.8/30 V dc

Subtotal (1 unit)*

Kr.1 014 90 

(exc. VAT)

Kr.1 268 62 

(inc. VAT)

Add to Basket
Select or type quantity
In Stock
  • 9 unit(s) ready to ship
  • Plus 7 unit(s) ready to ship from another location
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units
Per unit
1 +Kr. 1 014,90

*price indicative

RS Stock No.:
213-3777
Mfr. Part No.:
FLN-OSSD1000105
Brand:
SICK
Find similar products by selecting one or more attributes.
Select all

Brand

SICK

Product Type

Input/Output Module

Series

FLEXIL

Sub Type

Flexi Loop/Node for Safety Sensor

For Use With

Flexi Soft System

Supply Voltage

16.8/30 V dc

Number of Inputs

1

Power Rating

45V

Hazardous Area Certification

No

Standards/Approvals

SILCL3 (EN 62061), PL e (EN ISO 13849), Category 4 (EN ISO 13849), SIL3 (IEC 61508), TM 20 years (EN ISO 13849), PFHD (EN ISO 13849)

COO (Country of Origin):
HU

Overview


At a glance


Your Benefit


Flexi Loop can connect up to 32 safety sensors in series in compliance with the highest performance level PL e. Safety switches and safety sensors with OSSD outputs can be used together, regardless of manufacturer. Detailed diagnostic information is also available for each sensor or switch. Integrated switching signals allow for the use of interlocks, switches, and lamps. All sensors are supplied with voltage directly from the Flexi Loop. Unshielded standard cables are used with M12 male connectors. Ultimately, Flexi Loop can be relied upon for maximum safety. Connecting sensors in series reduces the amount of wiring and the number of safety inputs in the control cabinet. It also provides a comprehensive diagnostic check of all doors, emergency stop pushbuttons, and sensors. In conjunction with Flexi Soft and Flexi Classic, the entire safety application is able to cost-effectively meet customer needs.

Applications


Connecting both safety switches and safety sensors with OSSD outputs in series minimizes the amount of wiring and the number of inputs at the safety controller, thus reducing costs.

Simple calculation of the performance level saves time since the Flexi Loop node monitors each sensor individually

Quick and easy configuration saves time

Ability to be used over long distances increases application flexibility

Detailed diagnostic information – who switched and why? minimizes system downtime

Seamless system integration and communication with other SICK safety controllers

Detailed status information on Flexi Loop components, diagnostic accessories, and safety controller enable quick and easy field diagnosticsSeries connection of 32 sensors with up to 100 m per segment in compliance with performance level PL e

Compatible with sensors from all manufacturers

Detailed diagnostic information

Integrated standard inputs and outputs

Voltage supply for sensors is included

Related links