Contactor & Thermal Overload Relays | RS
Login / Register to access your benefits
Recently searched

    Contactor Overload Relays

    All electric motors have a lifespan, and to keep them running efficiently and safely they must be protected. One of the main causes of failure is electrical overload, sometimes called overcurrent. When a motor draws more current than it is designed to handle it causes the temperature to build-up resulting in overheating. This damages motor windings and coils. It is important to protect the motor and its circuit, and this is where the use of contactor overload relays can help.RS offer an extensive range of high-quality contactor overload relays from leading industry brands including Schneider Electric, Siemens, ABB, Eaton, Lovato, and Rockwell Automation.

    What is overload protection?

    Overload is where a motor draws a high current above its rated value for an extended amount of time. Overload causes overheating of the motor causing damage. To prevent this from happening devices such as contactor relays are specifically designed for industrial control motor protection. They are used with contactors as part of a motor starter or in a control panel or centre.

    What are the different types of contactor overload relays?

    The motor protection devices can be classified into two main types which are thermal types and electronic types.Thermal overload relaysUtilise a bi-metallic plate located near a heating element. When excessive current is passed through the heating element N/C (Normally Closed) contacts switch over and opens contacts. This interrupts power from flowing to the contactor's control circuit. Thermal overloads usually offer an adjustable current range as well as a manual or automatic reset option.Electronic RelaysElectronic overload relays don't have a bi-metallic mechanism, Instead, they work by using components such as temperature sensors to measure the load current. They are generally more accurate than thermal devices and they usually have a wider current range, a selectable trip class provides enhanced trip protection against single phasing against the motor.

    1452 Products showing for Contactor Overload Relays

    Eaton
    40 → 57 A
    57 A
    -
    -
    690 V ac
    -
    Direct Contactor
    7.5 W
    1NO + 1NC
    Automatic, Manual
    Screw
    2
    60mm
    132mm
    172mm
    +55°C
    -5°C
    -
    -
    -
    -5 → +55 °C
    Eaton
    0.6 → 1 A
    1 A
    -
    -
    690 V ac
    ZB
    Direct Contactor
    6 W
    1NO + 1NC
    Automatic, Manual
    Screw
    2
    45mm
    88mm
    88mm
    +55°C
    -25°C
    -
    -
    -
    -25 → +55 °C
    Schneider Electric
    -
    10 A
    TeSys
    3PST
    -
    -
    -
    0.0018 kW
    3NO + 1NC
    -
    -
    -
    -
    -
    -
    -
    -
    -
    Yes
    Green Premium
    -
    Schneider Electric
    -
    10 A
    TeSys
    -
    -
    -
    -
    -
    1 NO + 1 NC
    -
    -
    -
    -
    -
    -
    -
    -
    -
    Yes
    Green Premium
    -
    ABB
    0.8 → 2.7 A
    2.7 A
    AF Range
    3P
    600 V ac, V dc
    EF19
    Direct Contactor
    0.058 W
    1NO + 1NC
    Automatic, Manual
    Screw
    2
    44.4mm
    59.3mm
    59.3mm
    +70°C
    -25°C
    -
    -
    -
    -25 → +70 °C
    Schneider Electric
    -
    10 A
    TeSys
    4PST
    -
    -
    -
    0.003 kW
    4NO
    -
    -
    -
    -
    -
    -
    -
    -
    -
    Yes
    Green Premium
    -
    Schneider Electric
    5.5 → 8 A
    8 A
    TeSys
    3P
    690 V ac
    LR2K
    Under Contactor
    100 W
    1NO + 1NC
    Automatic, Manual
    Screw
    2
    45mm
    65mm
    116mm
    +55°C
    -20°C
    -
    Yes
    Green Premium
    -20 → +55 °C
    Lovato
    -
    -
    BGF00
    4P
    -
    -
    -
    -
    2NC, 2NO
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    Siemens
    11 → 16 A
    16 A
    SIRIUS
    3P
    690 V ac
    SIRIUS 3RU2
    Direct Contactor
    7.5 kW
    1NO + 1NC
    Automatic, Manual
    Screw
    2
    45mm
    73mm
    87mm
    +70°C
    -40°C
    -
    -
    -
    -40 → +70 °C
    Schneider Electric
    125 → 500 A
    125 → 500 A
    TeSys
    1 NO + 1 NC
    -
    -
    -
    -
    1 NO + 1 NC
    -
    -
    -
    -
    -
    -
    -
    -
    -
    Yes
    Green Premium
    -
    Schneider Electric
    4 → 6 A
    6 A
    TeSys
    -
    690 V ac
    LR3D
    DIN Rail Mount
    -
    -
    Push Button
    Screw
    -
    45mm
    70mm
    -
    +60°C
    -20°C
    -
    Yes
    Green Premium
    -20 → +60 °C
    ABB
    67 A
    6 A
    AF Range
    3P
    600 V ac/dc
    TF65
    Under Contactor Mount
    -
    1NO + 1NC
    Automatic, Manual
    Flat
    2
    87.7mm
    106.9mm
    64.9mm
    +60°C
    -25°C
    -
    -
    -
    -25 → +60 °C
    ABB
    0.74 → 1.0 A
    1 A
    Thermal Overload Relays
    3P
    -
    -
    -
    -
    1NC/1NO
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    Eaton
    0.4 → 0.6 A
    600 mA
    -
    3P
    -
    -
    -
    -
    NO/NC
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    Schneider Electric
    5 → 60 A
    60 A
    TeSys
    -
    690 V ac
    LT47
    Direct Contactor
    55 W
    1NO + 1NC
    Manual
    Screw
    2
    70.3mm
    77.2mm
    71mm
    +60°C
    -25°C
    -
    -
    -
    -25 → +60 °C
    Siemens
    16 A
    16 A
    SIRIUS
    -
    -
    SIRIUS 3RU2
    -
    7.5 kW, 11 kW
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    Schneider Electric
    110 A
    10 A
    TeSys
    -
    -
    -
    -
    0.045 kW
    3NO + 1NC
    -
    -
    -
    -
    -
    -
    -
    -
    -
    Yes
    Green Premium
    -
    Schneider Electric
    5 → 60 A
    60 A
    TeSys
    -
    690 V ac
    LT47
    Direct Contactor
    55 W
    1NO + 1NC
    Manual
    Screw
    2
    70.3mm
    77.2mm
    71mm
    +60°C
    -25°C
    -
    -
    -
    -25 → +60 °C
    ABB
    1.7 → 2.3 A
    2.3 A
    AF Range
    3P
    690 V ac/dc
    TF42
    Direct Contactor
    2 W
    1NO + 1NC
    Automatic, Manual
    Screw
    2
    45mm
    70.5mm
    88.3mm
    +60°C
    -25°C
    -
    -
    -
    -25 → +60 °C
    Schneider Electric
    13 A
    5 A
    TeSys
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    Yes
    Green Premium
    -
    Results per page