Circuit Trips | Auto Reclosers | RS
Login / Register to access your benefits
Recently searched

    Circuit Trips

    Circuit trips react to ground faults, short circuits or thermal overload in circuit breakers. A circuit trip opens the circuit in the event of a faulty condition. The trip becomes activated when it senses heat from an overload or high current from a short circuit.

    What are the different types of circuit trips?

    There are two types of circuit trips: electromechanical and electronic. An electromechanical circuit trip has two moving parts that work together to determine when to open the circuit. The two parts are a current-sensitive device and a thermal-sensitive device. An electric circuit trip is less mechanical as it's a programmable device. It measures and times the current flowing through the circuit breaker, electronically delivering a trip signal when it's needed.

    How to choose the right circuit trips

    Choosing the right circuit trips depends on the circuit or device and appliance you're using it for. There are various features that should be considered when selecting the right circuit trips, such as rated-control voltage and the current rating.

    An auto recloser is a type of circuit breaker equipped with a mechanism that automatically closes the breaker after it has been opened due to a fault. Reclosers are used to detect overcurrent and interrupt momentary faults in electrical distribution networks. To prevent damage, each station along a network is protected with circuit breakers which turn the power off if there is a short circuit. Reclosers are programmed to automate the reset process and start the restoration service.

    Why Have an Auto Recloser?

    Firstly, reclosers prevent transient short circuits from triggering prolonged power outages. This could be a broken tree branch momentarily hitting an overhead cable before it hits the ground. Having a recloser results in a better service to the customer as the power is restored within a few seconds.

    Secondly, the recloser is able to restore power automatically without the requirement of an engineer unless the fault is more serious.

    400 Products showing for Circuit Trips

    Allen Bradley
    -
    Bulletin
    189
    MCBs
    Shunt Trip
    60V ac/dc
    -
    -
    Schneider Electric
    630A
    Compact
    NSX
    -
    -
    -
    Yes
    Green Premium
    Siemens
    63A
    Sentron
    -
    -
    -
    -
    -
    -
    Allen Bradley
    -
    Bulletin
    189-AL
    1492-D DC Circuit Breaker, 188 Regional Circuit Breakers
    Auxiliary Release
    24 V dc, 60 V dc, 110 V dc, 220 V dc, 230 V ac, 400V ac
    -
    -
    Siemens
    -
    Sirius
    3RV2
    3RV2 Series Circuit Breakers
    Shunt Trip
    20 → 24V ac
    -
    -
    Eaton
    -
    Xboard
    -
    N(S)1(-4) Series, NZM1(-4) Series
    Shunt Trip
    208 → 250V ac/dc
    -
    -
    Schneider Electric
    250A
    Compact
    Micrologic 4.2
    Compact NSX 250 Circuit Breakers
    -
    440V ac
    -
    -
    Schneider Electric
    160A
    ComPacT New Generation
    NSXm 160E
    Circuits
    Circuit Breaker
    440V ac
    -
    -
    Schneider Electric
    100A
    Compact
    Micrologic 2.2 G
    Compact NSX 100/160/250 Circuit Breakers
    -
    690V ac
    -
    -
    Eaton
    -
    -
    -
    PKE, Shunt release PKZ0(4)
    Shunt Release
    -
    -
    -
    Allen Bradley
    -
    Bulletin
    140MP
    Motor Protection Circuit Breakers
    Shunt Trip
    -
    -
    -
    Siemens
    100mA
    -
    Sentron
    -
    -
    -
    -
    -
    Siemens
    -
    SIRIUS
    -
    Circuit Breaker 3RV1011
    Undervoltage Release
    400V (Volts)
    -
    -
    Schneider Electric
    6A
    Multi 9
    M9A
    Multi 9 C60 C60BP, Multi 9 C60 C60BPR, Multi 9 C60 C60SP, Multi 9 C60H-DC, Multi 9 GFP
    -
    -
    Yes
    Green Premium
    Eaton
    3.5A
    -
    -
    PKE, Trip indicator PKZ0(4)
    Tool
    250V dc
    -
    -
    Schneider Electric
    -
    Acti 9
    ARA iID
    4P iID
    -
    -
    Yes
    Green Premium
    Siemens
    16A
    SENTRON
    5TT4
    -
    -
    230V ac
    -
    -
    Siemens
    20A
    SENTRON
    5TE4
    -
    -
    400V ac
    -
    -
    Siemens
    -
    Sirius
    3RV2
    3RV2 Series Circuit Breakers
    Undervoltage Release
    400 V ac, 440V ac
    -
    -
    Schneider Electric
    250A
    Compact
    MH
    Compact NSX 250 Circuit Breakers
    Electronic Earth Leakage
    440 → 550V ac
    -
    -
    Results per page