    Current transformers or (CT’s), also known as Core Balance Current Transformers or Current Transducers, are instruments that are used to reduce or multiply the current from a high current into a lower current or vice versa. This is done so that the power can then be easily managed by Relays and measurement tools for electrical circuits and processes. Current Transformers consist of a core, a primary and a secondary winding.

    RS offer an extensive range of highly accurate Core Balance Current Transformers in various transformer types, current ratings, CT ratio supply voltages and mounting types to suit every application. Supplied by industry-leading brands including Siemens, Murata Power Solutions LEM and of course RS PRO.

    How does a current transformer work?

    When an alternating current flows through the primary winding, a magnetic flux is created which then induces an alternating current in the secondary winding. This alternating current is proportional to the current in its primary. Current transformers are also known as a “step-down transformer”. Once the current has been reduced it can be safely monitored and measured using an Ammeters

    Types of current transformer

    Toroidal Current Transformer

    • These transformers are shaped like a doughnut they do not contain a primary winding. Instead, the line that carries the current flowing in the network is threaded through a window or hole in the toroidal transformer. Toroidal transformers offer high efficiency with minimal excess noise and little excess leakage inductance.

    Wound Current Transformer

    -The transformers primary winding is physically connected in series with the conductor that carries the measured current flowing in the circuit. The magnitude of the secondary current is dependent on the turn’s ratio of the transformer.

    Bar-type Current Transformer

    – This type of current transformer uses the actual cable or bus-bar of the main circuit as the primary winding, which is equivalent to a single turn. They are fully insulated from the high operating voltage of the system and are usually bolted to the current-carrying device.

    Where would I use a Current Transducer?

    CTs are used in a wide range of industrial and commercial measurement applications. Some of the most common are:

    • Generating Stations
    • Electrical Substations
    • Commercial Electric
    • Power Distribution
    • Electrical Panels

    Browse the broad range of Current Transformers RS have to offer and order today for next day delivery.

    1633 Products showing for Current Transformers

    LEM
    150:1
    13.5 x 10mm
    LA
    -
    Closed Loop
    12 → 15 V
    150A
    75 mA
    33mm
    37mm
    16mm
    -40°C
    +85°C
    -
    -
    PCB Mount
    Phoenix Contact
    -
    -
    MCR-SL-CUC-400-I
    Current Transformer
    -
    24 V dc
    0 → 400A
    4 → 20 mA
    33.8mm
    90mm
    85mm
    -40°C
    +65°C
    -
    -
    DIN Rail
    RS PRO
    50:1
    21 x 10mm
    -
    -
    -
    -
    -
    -
    65mm
    7.2mm
    40mm
    -
    -
    -
    -
    -
    RS PRO
    2500:1
    9.5mm
    -
    -
    -
    -
    50A
    -
    -
    11.12mm
    23.8mm
    -40°C
    +85°C
    -
    -
    PCB Mount
    Carlo Gavazzi
    100:5
    23.3mm
    CTD1X
    -
    Closed Loop
    -
    100A
    5 A
    83mm
    46mm
    -
    -
    -
    -
    -
    -
    RS PRO
    1000:1
    11.4mm
    -
    -
    -
    -
    75A
    -
    -
    14.3mm
    30.2mm
    -55°C
    +130°C
    -
    -
    PCB Mount
    ABB
    500:5
    50mm
    CM
    Current Transformer
    Current Transformer
    -
    500A
    5 A
    78.5mm
    61mm
    48mm
    -
    -
    -
    -
    -
    Phoenix Contact
    -
    -
    PACT RCP
    Rogowski Coil
    Closed Loop
    -
    4000A
    1 A
    70.4mm
    22.5mm
    85mm
    -40°C, -30°C
    +70 °C, +80°C
    -
    -
    DIN Rail
    RS PRO
    250:5
    35mm
    -
    Base Mounted
    -
    -
    250A
    5 A
    87.5mm
    105mm
    38mm
    -
    -
    -
    -
    Surface Mount
    ABB
    -
    -
    CMS
    Solid Core
    Current Transformer
    690 V
    0.1 → 20A
    -
    43.2mm
    17.4mm
    51.5mm
    -25°C
    +70°C
    -
    -
    DIN Rail
    LEM
    100:1
    18mm
    AP
    -
    Closed Loop
    24 V dc
    100A
    -
    69mm
    67mm
    55mm
    -20°C
    +60°C
    -
    -
    DIN Rail
    LEM
    800:1
    30.2mm
    LF
    -
    Closed Loop
    15 → 24 V
    800A
    100 mArms
    70.3mm
    80mm
    40mm
    -40°C
    +70°C
    -
    -
    Panel Mount
    LEM
    300:1
    32mm
    HTA
    -
    Open Loop
    ±15 V
    300A
    -
    70mm
    17mm
    27.5mm
    -25°C
    +85°C
    -
    -
    Panel Mount
    Nuvotem Talema
    40:1
    -
    AZ
    -
    -
    -
    40A
    ±150 A
    23mm
    35mm
    -
    -40°C
    +85°C
    -
    -
    Flying Lead
    RS PRO
    125:5
    21 x 10mm
    -
    Base Mounted
    -
    -
    125A
    5 A
    65mm
    45mm
    40mm
    -5°C
    +55°C
    -
    -
    Surface Mount
    LEM
    70:1
    -
    LA
    -
    Closed Loop
    12 → 15 V
    70A
    50 mArms
    27.6mm
    36.6mm
    14.45mm
    -40°C
    +85°C
    -
    -
    PCB Mount
    LEM
    50:1
    -
    LAH
    -
    Closed Loop
    12 → 15 V
    50A
    25 mArms
    21mm
    33.3mm
    114.5mm
    -25°C
    +85°C
    -
    -
    PCB Mount
    Seneca
    -
    -
    RC190
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    Phoenix Contact
    -
    -
    -
    Rogowski Coil
    -
    -
    -
    -
    -
    -
    -
    '+80°C
    -30°C
    -
    -
    -
    KEMET
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    PCB Monut
    Results per page